Inhaltszusammenfassung zur Seite Nr. 1
42" and 50" Wood Burning MaSonry Fireplace
oWner’S opera Tion and inST alla Tion Manual
ICBO# 3507
(V)G42/50 - Smooth Face with Insulation
(V)G42R/50R - Smooth Face with Insulation and Bottom Door Rail
(V)G42H/50H - Smooth Face with Insulation and Herringbone Refractory
(V)G42HR/50HR - Smooth Face with Insulation, Bottom Door Rail
and Herringbone Refractory
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains inf
Inhaltszusammenfassung zur Seite Nr. 2
WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualified installer or local distributor. TaBle oF conTenTS Safety Information ............................................... Glass Door Installation ...................................... 1 Specifications ...................................................... 3 Operation and Maintenanc
Inhaltszusammenfassung zur Seite Nr. 3
SpeciFica TionS 42" MODELS ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 1 1 /2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS HEARTH EXTENSION 66" X 20" 0" TO 12" EACH SIDE BOTTOM 12" 30.5" 11" 67" 21.25" 58" 28.5" 49" 30" 0.625" 51" 42" 8" 51" 1" AIR KIT KNOCK OUT LEFT SIDE 24.25" GAS LINE KNOCK OUTS 3.5" 10.5" 9.5"
Inhaltszusammenfassung zur Seite Nr. 4
SpeciFica TionS 50" MODELS ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 1 1 /2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS HEARTH EXTENSION 74" X 20" 0" TO 12" EACH SIDE BOTTOM 12" 38.5" 11" 67" 21.25" 58" 28.5" 49" 30" 0.625" 59" 50" 8" 59" 1" AIR KIT KNOCK OUT LEFT SIDE 32.75" GAS LINE KNOCK OUTS 3.5" 10.5"
Inhaltszusammenfassung zur Seite Nr. 5
and depth of the fireplace. Firelp ace inSTalla Tion 3. Set the fireplace directly in front of this open- SELECTING LOCATION ing and slide the unit back until the nailing To determine the safest and most efficient location flanges touch the side framing. for the fireplace, you must take into consideration 4. Check the level of the fireplace and shim with the following guidelines: sheet metal if necessary. 1. The location must allow for proper clearances 5. Before securing fireplace to prepa
Inhaltszusammenfassung zur Seite Nr. 6
MANTELS Firelp ace inSTalla Tion A mantel may be installed if desired (see Figure 4). Continued Woodwork such as wood trims, mantels or any other HEARTH ExTENSION combustible material projecting from the front face A hearth extension projecting a minimum of 20" must not be placed within 12" of the fireplace open- in front of and a minimum of 12" beyond each ing. Combustible materials above 12" and projecting 1 side of the fireplace opening is required to protect more than 1 / " from the f
Inhaltszusammenfassung zur Seite Nr. 7
VenTing inST alla Tion LINEAL GAIN PART NO. DESCRIPTION GAIN OPTIONAL OUTSIDE AIR KIT 1 Georgian Fireplace 66 / " (MODEL AK4/AK4F) 12-12DM 5 Pipe Section 10 / " 8 The installation of an outside air kit should be per- 12-12HT formed during the rough framing of the fireplace 18-12DM 5 Pipe Section 16 / " 8 due to the nature of it's location. Outside combus- 18-12HT tion air is accessed through a vented crawl space 24-12DM 5 (AK4F) or through a sidewall (AK4). Pipe Section 3 / " 8 24-12HT 36-
Inhaltszusammenfassung zur Seite Nr. 8
2. Chimney weight above offset rests on return VenTing inST alla Tion elbow. Straps must be securely nailed to rafters Continued or joists (see Figure 8, details a and b). USING ELBOW OFFSETS (30E-12DM) 3. Maximum length of pipe between supports 1. To achieve desired offset, you may install (return elbow or 12S-12DM) is 6' of angle combinations of 12", 18", 24", 36" and 48" run. Maximum of two 6' angle run sections length of double wall pipe (see offset chart per chimney system (see Figu
Inhaltszusammenfassung zur Seite Nr. 9
PENETRATING THE ROOF VenTing inST alla Tion To maintain a 1" clearance to the pipe on a roof Continued with a pitch, a rectangular opening must be cut. 1. Determine the center point through which the pipe will penetrate the roof. 2. Determine the center point of the roof. Pitch Screws is the distance the roof drops over a given B span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters. 3. Use the roof opening chart (Figu
Inhaltszusammenfassung zur Seite Nr. 10
VenTing inST alla Tion CAUTION: Do not seal open- Continued ings on the rooftop flashing. Fol- Storm low the installation instructions Overlap Collar Shingles Top provided with the termination Flashing and Sides Only being used. Cone Nail Only RTL-10D Outer Stainless Perimeter Level of Inner Flue of Flashing Flue Gas Pipe Outlet Secure Termination to Outer Waterproof Pipe with 3 Caulking Underlap Screws Storm Shingles Collar at Bottom Flashing Figure 13 - Flashing Installation
Inhaltszusammenfassung zur Seite Nr. 11
3. Run a 1/2" black iron gas line into the fireplace VenTing inST alla Tion through the rear at gas line conduit sleeve (if Continued using a raised platform, add height). Provide 10 FOOT RULE sufficient gas line into fireplace chamber for All flue gas outlet chimney terminations must fitting connection (see Figure 19). Note: Secure incoming gas line to wood framing to extend a minimum of 3 feet in height above the highest point where it passes through the roof and provide rigidity for th
Inhaltszusammenfassung zur Seite Nr. 12
opTional gaS line la g SS door inSTalla Tion inSTalla Tion Continued IMPORTANT: Install glass door frame before installing glass CAUTION: All gas piping door. and connections must be tested for leaks after the installation INSTALLING DOOR FRAMES is completed. After ensuring 1. Remove screws from smoke shelf (see that the gas valve is on, apply Figure 20). soap and water solution to all 2. Mount top door frame and secure with screws removed in step 1. connections and joints. Bubbles
Inhaltszusammenfassung zur Seite Nr. 13
la g SS door opera Tion and inSTalla Tion MainTenance Continued guidelineS INSTALLING GLASS DOORS GLASS DOORS Spring clips have been installed but some adjust- Glass doors are optional with the fireplace. When ments may be needed. If doors do not close properly fireplace is in operation, doors must be fully or do not appear straight, see Door Adjustment. opened or fully closed position only or a fire hazard 1. With bi-fold doors completely folded, insert may be created (see Figure 24). bo
Inhaltszusammenfassung zur Seite Nr. 14
opera Tion and Damper MainTenance Weight uideline g S Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material To Close to clean glass. Do not clean glass with any cool Damper water if glass is still hot from the fire and smoke. A gas line or gas log lighter may be installed for the purpose of installing a vented or vent-free deco- rative gas appliance incorporating an automatic shutoff device and complying with the Stand
Inhaltszusammenfassung zur Seite Nr. 15
replaceMenT p ar TS HERRINGBONE BRICK LINER Bottom Front Brick Refractory 111509-01 - VG42H Models 111509-02 - G42H Models STANDARD BRICK LINER 111515-01 - VG50H Models Bottom Front Brick Refractory 111515-02 - G50H Models 111425-01 - VG42 Models Bottom Rear Brick Refractory 111425-02 - G42 Models 111510-01 - VG42H Models 111430-01 - VG50 Models 111510-02 - G42H Models 111430-02 - G50 Models 111512-01 - VG50H Models Bottom Rear Brick Refractory 111512-02 - G50H Models 111426-01 - VG42 Models
Inhaltszusammenfassung zur Seite Nr. 16
acceSSorieS OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION - AK-4 PN 01576 BI-FOLD GLASS DOOR STORM COLLAR - SC2-1 BDG42 - 42" Black Finish BDG42B - 42" Brushed Brass Finish BDG42P - 42" Platinum Finish FIRESTOP SPACER BDG42PB - 42" Polished Brass Finish FS-10 BDG50 - 50" Black Finish BDG50B - 50" Brushed Brass Finish BDG50P - 50" Platinum Finish BDG50PB - 50" Polished Brass Finish ROOF FLASHING V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch DOUBLE WALL PIPE - 12-12DM, 18-12