Inhaltszusammenfassung zur Seite Nr. 1
Owner's ManuaJ
®
POWER MISERTM 9
ELECTRIC
WATER HEATER
FOR POTABLE WATER HEATING ONLY.
NOT SUITABLE FOR SPACE HEATING.
MODEL NO.
153.329264 38 Gallon Short
153.329265 38 Gallon Short
153.329362 30 Gallon
i 52.329363 30 Gallon
i 53.329462 40 Gallon
i 53.329463 40 Gallon
i53.329562 55 Gallon
i 53.329563 55 Gallon
i 53.329662 65 Gallon
i 53.329663 66 Gallon
i 53.329862 80 Gallon
i 53.329863 80 Gallon
• Safety instructions
• installation
• Operation
• Care and Maintenance
• Troubleshooting
• Parts L
Inhaltszusammenfassung zur Seite Nr. 2
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety=related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater. to
Inhaltszusammenfassung zur Seite Nr. 3
Read andunderstand instruction improper installation and use may result manual and safety messages in property damage. before installing, operating or servicing thiswater heater. - Do not operate water heater if flood damaged. - Inspect and replace the anode as needed. Failure tofollow instructions and - Install in location with drainage. safety messages could result in - Fill tank with water before operation. death orserious injury. - Be alert for thermal expansion. Instruction manual must rema
Inhaltszusammenfassung zur Seite Nr. 4
"q! SAFE INSTALLATION, USEAND SERVICE ........................................................................................................................................ 2 GENERAL SAFETY ............................................................................................................................................................................. 3 TABLE OF CONTENTS ..................................................................................................................
Inhaltszusammenfassung zur Seite Nr. 5
The installation must conform with the instructions in this ThankYouforpurchasing a Sears waterheater. Properly manual; electric company rules; and Local Codes, or in the installed andmaintained, it should giveyouyears oftrouble absence of Local Codes, with the current edition of the freeservice. Itisstrongly suggested thatthisnew water heater beprofessionally installed, contact thelocalSearsService NEC - National Electrical Code, NFPA 70. This publication is available from your local government
Inhaltszusammenfassung zur Seite Nr. 6
Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation. m DRAIN PANS AVAILABLE IN 20" EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 DIAMETER FORWATER HEATERS HAVING A DIAMETER 18" OR LESS, GALLONS , AND 5 GALLONS CAPACITY THROUGH LOCAL SEARS STORE OR 24" DIAMETER FOR WATER SERVICE CENTER. HEATERS HAVING A DIAMETER 22" WATER HEATER INSTALLATION KI
Inhaltszusammenfassung zur Seite Nr. 7
The water passing out of the drain valve may be extremely hot. Removing the Old Water Heater To avoid being scalded, make sure all connections are tight and that the water flow is directed away from any person. 4. Check again to make sure the electrical supply is turned "OFF" to the water heater. Then unplug the water heater (cord set) or disconnect the electrical supply connection from the water heater junction box. FIGURE 4. 5a. If you have copper piping to the water heater, the two copper wat
Inhaltszusammenfassung zur Seite Nr. 8
• Sensors mounted in the drain pan that turn offthe water supply to the entire home when water is detected in the drain pan. • Water supply shut-off devices that activate based on the water Mineral Buildup or Sediment IVlayAccumalate pressure differential between the cold water and hot water pipes connected to the water heater. . This causes the water heater to become much heavier than normal. ® If spilled, could cause staining. Installations in Residential Garages Mineral buildup or sediment ma
Inhaltszusammenfassung zur Seite Nr. 9
HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Fire Hazard / Electric Shock Hazard Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water - Do not use this water heater with in you
Inhaltszusammenfassung zur Seite Nr. 10
Fit T & P valve insulation over valve. Make sure that the insulation NOTE: Toprotect against untimely corrosion ofhot and cold does not interfere with the lever of the T & P valve. water fittings, it is strongly recommended that di=electric unions or couplings be installed on this water heater when Secure all insulation using tape. connected to copper pipe. 1. Look at the top cover of the water heater. The hot water outlet is marked hot. Put two or three turns of teflon tape around PIPE INSULATI
Inhaltszusammenfassung zur Seite Nr. 11
Position thevalvedownward andprovide tubing sothatany Ifaftermanually operating thevalve, itfailstocompletely reset discharge willexitonlywithin 6inches (153mm)above, orat andcontinues to release water, immediately closethecold any distance below thestructural floor. Becertain thatnocontact water inlet tothewater heater, follow thedraining instructions, ismade withanyliveelectrical part.Thedischarge opening andreplace thetemperature-pressure reliefvalve witha new one. must not be blockedor reduc
Inhaltszusammenfassung zur Seite Nr. 12
Necessary element conversion parts are located in a small Converting the Lower Element bag contained within the electrical junction box on top of the water heater. These instructions only cover the conversion of the convertible element, read this entire manual before attempting to install or operate the water heater. The water heater is factory set to CONVERSION PARTS operate at 3800 watts. The lower element can be converted to operate at 5500 watts. Refer to "Facts to Consider About the Convert
Inhaltszusammenfassung zur Seite Nr. 13
LiFT OUT TAB TO UNCLIP 8. Tighten terminals 2 and 3 to ensure proper electrical TERMINAL COVER FROM connection. THERMOSTAT Fire and Explosion Hazard • Failure to tighten screws can cause a fire. • Failure to do this could result in death, serious bodily injury, or property damage. Failure to tighten terminal screws can cause a fire which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY FIGURE 16. DAMAGE. 5. Remove the screws from terminal 2 of the element, and 9. Replace terminal cover on
Inhaltszusammenfassung zur Seite Nr. 14
11. Replace the access panel. Fire Hazard / Electric Shock Hazard ® Do not use this water heater with any voltage other than shown on the model rating plate. Failure to use the correct voltage shown on the model rating plate FIGURE 21. could result in death, serious bodily injury, or property damage. 12. Complete wiring to the water heater, or if completed, turn "ON" electric power to the water heater after filling the tank with water. If wiring from your fuse box or circuit breaker box was alum
Inhaltszusammenfassung zur Seite Nr. 15
5. Wiring Diagrams (see "Wiring Diagrams" section) have been 6. Use wire nuts and connect the power supply wiring to the supplied showing the two most common types of wires inside the water heater's junction box. connections between the water heater and the power supply. You can easily see which type connection you have by 7. The water heater must be electrically "grounded" by the removing the junction box cover on top of the water heater. installer. A green ground screw has been provided on the
Inhaltszusammenfassung zur Seite Nr. 16
Wiring Diagrams STANDARD WIRING FOR 2 WIRE LEAD WATER HEATERS NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT A6 [ GROUND TE"M'NAL------F:-_I_-- * Before removing any access ,, Tl__T2?owersuPpLY panels or servicing the water ol ,.,I heater, make sure the electrical HI-TEMP JUNCTION supply to the water heater is LImit-_l(_'ll_-@l / BOX turned "OFF". SWITCH rJK_ I_ oP.E. _q , Failure to do this could result in THERMOSTAT .___ / death, serious bodily injury, or _ Lu property damage. BUSS OI _ _1
Inhaltszusammenfassung zur Seite Nr. 17
The lower thermostat is factory set at a position which Temperature Regulation approximates 120°F (49°C), and is adjustable if a different water temperature is desired• Read all warnings in this manual and on the water heating before proceeding• Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury TEMPERATURE or death• ADJUSTMENT m Children, the elderly, and the KNOB physically or mentally disabled are at highest risk for scald injury. Feel water before
Inhaltszusammenfassung zur Seite Nr. 18
NOTE: It is notnecessary to adjusttheupper thermostat. Temperature-Pressure Relief Valve Operation However, ifit isadjusted above thefactory setpoint of 120°F (49°C), it isrecommended thatit notbesethigher thanthe The temperature-pressure relief valve must be manually lower thermostat setting. operated at least once a year. Theupper andlower thermostats areadjustable ifa different watertemperature is desired.Readall warningsin the • Burn hazard "Temperature-Regulation" section before proceeding.
Inhaltszusammenfassung zur Seite Nr. 19
Thewater heater should bedrained ifbeing shutdown during 1. Turn "OFF" the electrical power to the water heater at the freezing temperatures. Also,periodic draining andcleaning of junction box. sediment fromthetankmaybenecessary. 2. Remove the access panel and the insulation cap with handle. l 3. Lift out the tab as shown below to unclip the terminal cover • Before removing any access from the thermostat. The terminal cover can now be removed panels or servicing the water from the thermostat. he
Inhaltszusammenfassung zur Seite Nr. 20
Remove the two screws securing the access panel, and remove panel. [ o Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF". • Failure to do this could result in death, serious bodily injury, or property damage. FIGURE 33. Before beginning turn "OFF" the electric power supply to the water heater. 5. Remove the insulation cap with handle. QI .___J FIGURE 30. 2. Turn off the water supply to the water heater at the wate