Installation Instructions
Installation Manual
+
Bosch Eco26
External Model
BC2600RA
To be installed and serviced only
by an authorised person
This appliance is not suitable for
use as a pool heater
The "authorised installing person" is
responsible for:
1. Correct commissioning of this
appliance.
2. Ensure unit performs to the
specifications stated on the
rating label.
3. Demonstrate operation of unit to
customer before leaving.
4. Hand these instructions to
customer.
This appliance must be
Inhaltszusammenfassung zur Seite Nr. 2
Installation Instructions Robert Bosch (Australia) Pty. Ltd. Installation Manual CONDENSING GAS WATER HEATER + Bosch Eco26 (Outdoor Installation) Potential dangers from accidents during installation and use are divided into the following three categories. Closely observe these warnings, they are critical to your safety. DANGER indicates an imminently hazardous situation which, DANGER if not avoided, will result in death or serious injury. WARNING indicates a potentially hazardous situ
Inhaltszusammenfassung zur Seite Nr. 3
Installation Instructions The following accessories are included with the unit. Check for any missing items before starting installation. 1. Included Accessories Part Shape Q’ty Part Shape Q’ty Owner's Guide, 1 Tapping Screw Installation Manual 5 each (this document) The accessories listed below are not included with the units, but may be necessary 2. Optional Accessories for installation. Part Shape Q’ty Part Shape Q’ty Main Controller Bathroom Controller Bath Fill Priority Burner on Bath Fill
Inhaltszusammenfassung zur Seite Nr. 4
Installation Instructions Before Installation 3. WARNING Check the Gas • Check that the data plate (located inside of front cover) or a temporary label (located on the front cover) For NG Gas indicates the correct type of gas. • Check that the gas supply line is sized for 178 MJ/hr for this unit. • DO NOT OPERATE WITH ANY OTHER GAS TYPE. MODEL BC2600RA GAS TYPE : NG GAS CONSUMPTION : 178MJ/hr Check the Power HEAT OUTPUT : 45.7kW ELECTRICAL RATING : AC240/230V 50Hz • The power supply required
Inhaltszusammenfassung zur Seite Nr. 5
Installation Instructions Choosing Installation Site 4. * Locate the appliance in an area where water leakage from the unit or connections will not result in damage to the area adjacent to the appliance or to the lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow. DANGER • This water heater is for outdoor installation only. Never ins
Inhaltszusammenfassung zur Seite Nr. 6
Installation Instructions CAUTION • Install the water heater in a location where it is free from obstacles and stagnant air. • Consult with the customer concerning the location of installation. • Do not install the water heater near staircases or emergency exits. • Do not install the water heater where the exhaust will blow on outer walls or material not resistant to heat. Also consider the surrounding trees and animals. The heat and moisture from the water heater may cause discoloration of wall
Inhaltszusammenfassung zur Seite Nr. 7
Installation Instructions CLEARANCES FOR FLUE TERMINAL (front of heater) The location of the flue terminal must comply with the clearances shown on this page. If you are unsure about clearances not indicated here, in general refer to AS5601, or your local authority. In Western Australia refer to the WA Office of Energy rules and regulations. a c T j jj h h W e e n door h f d g P k d T I M b c g k T Use as a guide only. Refer to AS5601 or local gas fitting rules for specific locations T=Flue ter
Inhaltszusammenfassung zur Seite Nr. 8
Installation Instructions 6. Installation Securing to the wall • Installation must conform with all local building, water or Gas Regulations or AS5601. • The weight of the device will be applied to the wall. If the strength of the wall is not suffi- cient, reinforcement must be done to prevent the transfer of vibration. • Do not drop or apply unnecessary force to the device when installing. Internal parts may Be sure to do be damaged and may become highly dangerous. • Install the unit on a verti
Inhaltszusammenfassung zur Seite Nr. 9
Installation Instructions Follow the instructions from the gas supplier. Gas Piping 7. The appliance must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 3.5 kPa. The appliance and its gas connections must be leak tested before placing the appliance in operation. The inlet gas pressure must be within the range specified. This is for the purposes of input adjustment. In order to choose the proper size for the gas line, c
Inhaltszusammenfassung zur Seite Nr. 10
Installation Instructions Installation and service must be performed by a qualified plumber. 8. Water Piping Observe all applicable codes. This appliance is suitable for potable water applications. Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and gas control which has been under water. Piping and components connected to the water heater shall be suitable for use with
Inhaltszusammenfassung zur Seite Nr. 11
Installation Instructions Supply water piping Hot water piping • Do not use PVC, iron, or any piping which has • Do not use lead, PVC, iron or any piping which been treated with chromates, boiler seal or other has been treated with chromates, boiler seal or chemicals. other chemicals. • Pipe sizing from the cold water supply should be • Keep the pipe lengths to a minimum, and make sized according to local BY LAWS for water supply. sure that the pipework is well insulated as correct • If sludge o
Inhaltszusammenfassung zur Seite Nr. 12
Installation Instructions 9. Condensate Piping PLEASE FOLLOW LOCAL CODES ABOUT CONDENSATE PIPING. • This water heater is a high efficiency, fully condensing appliance which produces condensate during operation. Therefore, it is necessary to install condensate piping. The water heater incorporates a col- lection, neutralization, and removal system which must be properly drained in order to ensure proper operation of this appliance. • The water heater is supplied with a pre-installed condensate ne
Inhaltszusammenfassung zur Seite Nr. 13
Installation Instructions Consult a qualified electrician Electrical Wiring for the electrical work. 10. Do not connect electrical power to the unit until all electrical wiring has been completed. Disconnect Power This appliance must be electrically earthed in accordance with Electrical Authority Regulations. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Field wiring to
Inhaltszusammenfassung zur Seite Nr. 14
Installation Instructions Remote Controller The remote controller will indicate when the neutralizer unit is in need of replacement by displaying an error code. Therefore, the remote controller should always be installed with this water heater in order to prevent an unexpected disruption of hot water service. Applicable Model Bathstop Max temperature 75°C * Main controller YPRM67XB Max temperature 50°C Bathroom controller YPRS67XB Sub controller Max temperature 50°C YPRP62XB * Maximum tempera
Inhaltszusammenfassung zur Seite Nr. 15
Installation Instructions Connecting Remote Controller Cord to Unit • Tie the redundant cord outside the water heater. Do not put the extra length inside the water heater. • The remote controller cord can be extended up to 20m. • Be sure to hand tighten when screwing to the terminal block. Power tools may cause damage to the terminal block. Remote controller cord • Use remote controller cord for any extensions. • Install according to the National Electrical Code and all applicable local codes. 1
Inhaltszusammenfassung zur Seite Nr. 16
Installation Instructions Periodically check the following to ensure proper Maintenance operation of the water heater. 11. • The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion. • The burner flame must be checked periodically for a proper blue colour and consistency. • If the flame does not appear normal, the burner may need to be cleaned. • If the burner needs to be cleaned, it must be performed by a qualified service technicia
Inhaltszusammenfassung zur Seite Nr. 17
Installation Instructions WARNING A fire or explosion may result if these instructions are not followed, which may cause lose of life, personal injury or property damage. Lighting Instructions This water heater does not have a pilot. It is equipped with an ignition device that automatically lights the burner. Do not try to light the burner by hand. 1. Read the safety information in the installation manual or on the right side of the water heater. 2. Turn off all electrical power to the unit. 3.
Inhaltszusammenfassung zur Seite Nr. 18
Installation Instructions Dimensions 13. 338 120 350 2-6.5 x 13 85 334 OBLONG HOLE 50 10 260 20 267 19 4- 13 28 FLUE COLLAR 4- 13 120 60 AIR INLET AIR INLET 2- 6.5 10 42 42 3-6.5 x 16.5 AIR INLET OBLONG HOLE 135 DRAIN OUTLET COLD WATER INLET WATER DRAIN VALVE WATER DRAIN VALVE (WATER FILTER) HOT WATER OUTLET WIRING THROUGHWAYS GAS INLET (VIEW FROM TOP) PRESSURE RELIEF VALVE (WATER DRAIN VALVE) 279 243 136 HEIGHT OF EACH FITTING HOT WATER 100 GAS INLET (R3/4) FROM BOTTOM OF CASE OUTLET