Inhaltszusammenfassung zur Seite Nr. 1
SI 5MER
SI 7MER
SI 9MER
Montage- und
Gebrauchsanweisung
SI 11MER
Installation and
Operating Instructions
Instructions d’installation
et d’utilisation
Sole/Wasser- Brine-to-Water Pompe à chaleur
Wärmepumpe für Heat Pump for eau glycolée-eau
Innenaufstellung Indoor Installation pour installation
intérieure
o
Bestell-Nr. / Order no. / N de commande : 452232.66.14 FD 8612
Français English Deutsch
Inhaltszusammenfassung zur Seite Nr. 2
Table of contents 1 Please Read Immediately .............................................................................................................E-2 1.1 Important Information..............................................................................................................................E-2 1.2 Legal Regulations and Directives ...........................................................................................................E-2 1.3 Energy-Efficient Use of the Heat Pum
Inhaltszusammenfassung zur Seite Nr. 3
English 1 1.2 Legal Regulations and 1 Please Read Directives Immediately This heat pump conforms to all relevant DIN/VDE regulations and EU directives. Refer to the EC Declaration of Conformity in 1.1 Important Information the appendix for details. The heat pump must be connected to the power supply in com- ATTENTION! pliance with all relevant VDE, EN and IEC standards. Any further The heat pump is not secured to the wooden pallet. connection requirements stipulated by local utility companies
Inhaltszusammenfassung zur Seite Nr. 4
3 2 Purpose of the Heat 3 Basic Device The basic device consists of a ready-to-use heat pump for indoor Pump installation, complete with sheet metal casing, control panel and integrated controller. The refrigerating cycle contains the refriger- 2.1 Application ant R407C. R407C refrigerant is CFC-free, non-ozone depleting and non-combustible. The brine-to-water heat pump is designed for use in existing or All components required for the operation of the heat pump are newly built heating systems.
Inhaltszusammenfassung zur Seite Nr. 5
English 4 4 Accessories 6Set-up 4.1 Brine Circuit Manifold 6.1 General Information The brine circuit manifold merges the individual collector loops of The unit may only be installed indoors in rooms with low humidity the heat source system into a single main pipe which is con- on a level, smooth and horizontal surface. The entire base of the nected to the heat pump. Integrated ball valves allow the individ- frame should lie directly on the floor to ensure a good soundproof ual brine circuits to
Inhaltszusammenfassung zur Seite Nr. 6
7.4 7.3 Heat Source Connection 7 Installation The following procedure must be observed when connecting the heat source: 7.1 General Information Connect the brine pipe to the heat pump flow and return. The hy- The following connections need to be established on the heat draulic plumbing diagram must be adhered to. pump: Flow and return flow of the brine system ATTENTION! Flow and return flow of the heating system The supplied dirt trap must be inserted in the heat source inlet of the heat pump
Inhaltszusammenfassung zur Seite Nr. 7
English 8 8.3 Start-up Procedure 8 Commissioning The heat pump is started up via the heat pump controller. 8.1 General Information ATTENTION! To ensure that start-up is performed correctly, it should only be The heat pump must be started up in accordance with the installation and carried out by an after-sales service technician authorised by the operating instructions of the heat pump controller. manufacturer. This may be a condition for extending the guaran- If an overflow valve is fitted to as
Inhaltszusammenfassung zur Seite Nr. 8
11 9 Maintenance and 10 Faults / Trouble- Cleaning Shooting This heat pump is a quality product and is designed for trouble- free operation. In the event that a fault should occur, it will be in- 9.1 Maintenance dicated on the heat pump manager display. Simply consult the The heat pump is maintenance-free. To prevent faults due to Faults and Trouble-Shooting page in the operating instructions of sediment in the heat exchangers, care must be taken to ensure the heat pump controller. that no impur
Inhaltszusammenfassung zur Seite Nr. 9
English 12 12 Device Information 1 Type and order code SI 5MER SI 7MER SI 9MER SI 11MER 2Design 2.1 Model Reversible Reversible Reversible Reversible 2.2 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20 2.3 Installation location Indoors Indoors Indoors Indoors 3 Performance data 3.1 Operating temperature limits: Heating water flow °C Up to 55 Up to 55 Up to 55 Up to 55 Cooling, flow °C +7 to +20 +7 to +20 +7 to +20 +7 to +20 Brine (heat source, heating) °C -5 to +25 -5 to +25 -5 t
Inhaltszusammenfassung zur Seite Nr. 10
Anhang / Appendix / Annexes 1 Maßbilder / Dimension Drawings / Schémas cotés................................................................... A-II 1.1 Maßbild / Dimension Drawing / Schéma coté.........................................................................................A-II 2 Diagramme / Diagrams / Diagrammes....................................................................................... A-III 2.1 Heizbetrieb / Heating operation / Mode chauffage SI 5MER ......................
Inhaltszusammenfassung zur Seite Nr. 11
Anhang · Appendix · Annexes 1 1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension Drawing / Schéma coté A-II
Inhaltszusammenfassung zur Seite Nr. 12
2.1 2 Diagramme / Diagrams / Diagrammes 2.1 Heizbetrieb / Heating operation / Mode chauffage SI 5MER A-III Anhang · Appendix · Annexes
Inhaltszusammenfassung zur Seite Nr. 13
Anhang · Appendix · Annexes 2.2 2.2 Kühlbetrieb / Cooling operation / Mode refroidissement SI 5MER A-IV
Inhaltszusammenfassung zur Seite Nr. 14
2.3 2.3 Heizbetrieb / Heating operation / Mode chauffage SI 7MER A-V Anhang · Appendix · Annexes
Inhaltszusammenfassung zur Seite Nr. 15
Anhang · Appendix · Annexes 2.4 2.4 Kühlbetrieb / Cooling operation / Mode refroidissement SI 7MER A-VI
Inhaltszusammenfassung zur Seite Nr. 16
2.5 2.5 Heizbetrieb / Heating operation / Mode chauffage SI 9MER A-VII Anhang · Appendix · Annexes
Inhaltszusammenfassung zur Seite Nr. 17
Anhang · Appendix · Annexes 2.6 2.6 Kühlbetrieb / Cooling operation / Mode refroidissement SI 9MER A-VIII
Inhaltszusammenfassung zur Seite Nr. 18
2.7 2.7 Heizbetrieb / Heating operation / Mode chauffage SI 11MER A-IX Anhang · Appendix · Annexes
Inhaltszusammenfassung zur Seite Nr. 19
Anhang · Appendix · Annexes 2.8 2.8 Kühlbetrieb / Cooling operation / Mode refroidissement SI 11MER A-X
Inhaltszusammenfassung zur Seite Nr. 20
3.1 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Control via the standard controller / Commande régulateur standard A-XI Anhang · Appendix · Annexes