Inhaltszusammenfassung zur Seite Nr. 1
LA 11PS
Montage- und
Gebrauchsanweisung
Installation and
Operating Instructions
Instructions d’installation
et d’utilisation
Luft/Wasser- Air-to-Water Heat Pompe à chaleur
Wärmepumpe für Pump for Outdoor air-eau pour
Außenaufstellung Installation installation
extérieure
o
Bestell-Nr. / Order no. / N de commande : 452159.66.17 FD 8703
Français English Deutsch
Inhaltszusammenfassung zur Seite Nr. 2
Table of contents 1 Please Read Immediately .............................................................................................................E-2 1.1 Important Information..............................................................................................................................E-2 1.2 Legal Regulations and Directives ...........................................................................................................E-2 1.3 Energy-Efficient Use of the Heat Pum
Inhaltszusammenfassung zur Seite Nr. 3
English 1 1.2 Legal Regulations and 1 Please Read Directives Immediately The construction and design of the heat pump complies with all relevant EU directives, DIN/VDE regulations (see CE declaration 1.1 Important Information of conformity). The relevant VDE, EN and IEC standards must be adhered to ATTENTION! when connecting the heat pump to the power supply or carrying Any work on the heat pump may only be performed by authorised and out maintenance work. Any further connection requirements s
Inhaltszusammenfassung zur Seite Nr. 4
3.1 2 Purpose of the Heat 3 Scope of Delivery Pump 3.1 Basic Device The heat pump is of compact design and is supplied complete 2.1 Application with the components listed below. The air-to-water heat pump is designed for use in existing or R290 (propane) is used as refrigerant. newly built heating systems. It is designed exclusively for heating domestic hot water and heating water! The heat pump is suitable for mono energy and bivalent opera- tion down to an external temperature of -20 °C. Pro
Inhaltszusammenfassung zur Seite Nr. 5
English 3.2 3.2 Switch Box 4 Transport The switch box is located in the heat pump. All electrical compo- ATTENTION! nents are accessible after the front cover and the switch box Never install the device in rooms in which there are any permanent cover have been removed. ignition sources. The switch box contains the supply connection terminals, the plug connector for the control line, as well as the power contac- ATTENTION! tors and the soft starter unit. When transporting the heat pump, ensure th
Inhaltszusammenfassung zur Seite Nr. 6
6.2 5Set-up 6 Installation 5.1 General Information 6.1 General Information The heat pump is suited for outdoor installation. The device The following connections need to be established on the heat should always be installed on a permanently smooth, even and pump: horizontal surface and must be aligned vertically. The entire Flow and return flow of the heating system frame should lie directly on the ground to ensure a good sound- Condensate outflow proof seal and to prevent the water-bearing co
Inhaltszusammenfassung zur Seite Nr. 7
English 6.3 7 Start-up 7.1 General Information To ensure that start-up is performed correctly, it should only be carried out by an after-sales service technician authorised by the manufacturer. This may be a condition for extending the guaran- tee (see Warranty Service). 7.2 Preparation The following items need to be checked prior to start-up: The heat pump must be fully connected, as described in Chapter 6. All valves that could impair the proper flow of the heating water in the heating ci
Inhaltszusammenfassung zur Seite Nr. 8
8.2 Any faults occurring during operation are also displayed on the 8 Maintenance / Cleaning heat pump controller and can be corrected as described in the operating instructions of the heat pump controller. 8.1 Maintenance For external temperatures below 10 °C and heating water tem- peratures below 16 °C, the buffer tank should be heated up with To protect the paintwork, avoid leaning anything against the de- the second heat generator to at least 25 °C. vice or putting objects on the device. Ex
Inhaltszusammenfassung zur Seite Nr. 9
English 8.3 8.3 Cleaning the Air System 9 Faults / Trouble- Evaporator, ventilator and condensate outflow should be cleaned Shooting of contamination (leaves, twigs, etc.) before each new heating period. This heat pump is a quality product and is designed for trouble- free and maintenance-free operation. In the event that a fault Do this by opening the front of the heat pump. The bottom should should occur, it will be indicated on the heat pump manager dis- be opened first followed by the top. p
Inhaltszusammenfassung zur Seite Nr. 10
11 11 Device Information 1 Type and order code LA 11PS 2Design 2.1 Degree of protection according to EN 60 529 for compact devices IP 24 and heating components 2.2 Installation Location Outdoors 3 Performance data 3.1 Operating temperature limits: Heating water flow/return flow °C / °C Up to 65 / above 18 Air °C -25 to +35 3.2 Temperature spread of heating water at A7 / W35 9.2 5.0 1 7.3 / 2.5 7.0 / 2.5 3.3 Heat output / COP at A-7 / W35 kW / --- 1 6.4 / 2.2 at A-7 / W45 kW / --- 1 9.2 / 3.1 8.
Inhaltszusammenfassung zur Seite Nr. 11
Anhang / Appendix / Annexes 1 Maßbild / Dimension Drawing / Schéma coté ............................................................................ A-II 2 Diagramme / Diagrams / Diagrammes....................................................................................... A-III 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques...................................................... A-IV 3.1 Steuerung / Control / Commande .................................................................
Inhaltszusammenfassung zur Seite Nr. 12
Anhang · Appendix · Annexes 1 1 Maßbild / Dimension Drawing / Schéma coté A-II
Inhaltszusammenfassung zur Seite Nr. 13
2 2 Diagramme / Diagrams / Diagrammes www.dimplex.de A-III Anhang · Appendix · Annexes
Inhaltszusammenfassung zur Seite Nr. 14
Anhang · Appendix · Annexes 3 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande A-IV
Inhaltszusammenfassung zur Seite Nr. 15
3.2 3.2 Last / Load / Charge www.dimplex.de A-V Anhang · Appendix · Annexes
Inhaltszusammenfassung zur Seite Nr. 16
Anhang · Appendix · Annexes 3.3 3.3 Anschlussplan / Circuit Diagram / Schéma électrique A-VI
Inhaltszusammenfassung zur Seite Nr. 17
3.4 3.4 Legende / Legend / Légende E1 Ölsumpfheizung Verdichter 1 Oil sump heater for compressor 1 Chauffage à carter d’huile compresseur 1 E4 Düsenringheizung Ventilator Nozzle ring heater, ventilator Chauffage à couronne perforée ventilateur F4 Pressostat Hochdruck Verdichter 1 High-pressure switch, compressor 1 Pressostat haute pression, circuit froid 1 F5 Pressostat Niederdruck Low-pressure switch Pressostat basse pression F23 Wicklungsschutz Ventilator Winding protection, ventilator Blindag
Inhaltszusammenfassung zur Seite Nr. 18
Anhang · Appendix · Annexes 4 4 Hydraulische Prinzipschemen / Hydraulic Plumbing Diagram / Schémas hydrauliques 4.1 Monoenergetische Anlage / Mono Energy System / Installation monoénergétique A-VIII
Inhaltszusammenfassung zur Seite Nr. 19
4.2 4.2 Monoenergetische Anlage und Warmwasserbereitung / Mono Energy System and Domestic Hot Water Preparation / Installation monoénergétique et production d’eau chaude www.dimplex.de A-IX Anhang · Appendix · Annexes
Inhaltszusammenfassung zur Seite Nr. 20
Anhang · Appendix · Annexes 4.3 4.3 Bivalente Anlage / Bivalent System / Installation bivalente A-X