Inhaltszusammenfassung zur Seite Nr. 1
READ AND SAVE THESE INSTRUCTIONS
AMERICA’S FAN COMPANY
52" “APOLLO” Series
Model No.
CF3900WW01 CF3900AW01 CF3900AB01
CF3900PB01 CF3900WPB01 CF3900OB01
CF3900HTW01 CF3900BS01 CF3900BQ01
CF3900TG01 CF3900CK01
Net Weight: 18.0 Lbs.
®
“APOLLO” Series
Ceiling Fan Owner's Manual
Part No. F40BP72340003 Form No. BP7234-3
Inhaltszusammenfassung zur Seite Nr. 2
LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime from the date you purchased your ceiling fan. All other components and accessories are covered by this warranty for one year from the
Inhaltszusammenfassung zur Seite Nr. 3
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
Inhaltszusammenfassung zur Seite Nr. 4
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 Three wire connectors (supplied.) One wire stripper ! WARNING MATERIALS Wiring outlet box and box connectors must be of type Before assembly your ceiling fan, refer to section on required by the local code. The minimum wire would be prop
Inhaltszusammenfassung zur Seite Nr. 5
Assembly Instructions 1. Remove the fan motor and housing assembly from 5.Remove the hanger ball by loosening the setscrew styrofoam packaging and position it so that the top in the hanger ball until the ball falls freely down the of the motor is facing you. downrod. Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger 2. Separate, untwist and unkink the three motor ball for reinstallation in step 8. leads. Route the motor leads through the hanger ball/downrod
Inhaltszusammenfassung zur Seite Nr. 6
9. The fan comes with blue, black and white leads 13. Remove the fan motor and housing assembly that are 80-inches long. Before installing fan, mea- from the styrofoam packaging. Position the motor sure up approximately 6 to 9-inches above the so that the bottom of the motor is facing you. ball/downrod assembly. Cut off excess leads and Engage the connector of the switch cup assembly strip back insulation 1/2-inch from end of leads. with the motor connector by aligning the V-notch shaped keyways
Inhaltszusammenfassung zur Seite Nr. 7
Electrical Requirements ! WARNING Your new ceiling fan will require a grounded electrical To reduce the risk of fire, electric shock, or personal supply line of 120 volts AC, 60 Hz, 15 amp circuit. injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet The outlet box must be securely anchored and capa- box. Most outlet boxes commonly used for support ble of withstanding a load of at least 50 pounds. of light fixtures are not acceptable for fan supp
Inhaltszusammenfassung zur Seite Nr. 8
5. Secure the ceiling cover in place by sliding lock- How to Wire Your washers over the threaded studs and installing the Ceiling Fan two knurled knobs (supplied). (Figure 5.) Tighten the knurled knobs securely until the ceiling cover If you feel that you do not have enough electrical fits snugly against the ceiling and the hole in the wiring knowledge or experience, have your fan ceiling cover is clear of the downrod. Your fan is installed by a licensed electrician. now wired to be turned on an
Inhaltszusammenfassung zur Seite Nr. 9
Attaching Light Kit Accessories 1. Ceiling Fan Light Kits (see store or catalog). ! WARNING 2. Ceiling Fan/Light Controls (see store or catalog). To avoid possible electrical shock, be sure electricity 3. Downrod Extension Kits (see store or catalog). is turned off at the main fuse box before wiring. ! WARNING To install an accessory light kit, remove the three screws securing the switch cup assembly to the fan, The use of any other control not specifically remove the switch cup assembly, and di
Inhaltszusammenfassung zur Seite Nr. 10
Repair Parts Before discarding packaging material, 2 be certain all parts have been removed. HOW TO ORDER REPAIR PARTS 1 3 WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: 16 • NAME OF ITEM • MODEL NUMBER • THE PART NUMBER 6 • THE PART DESCRIPTION 14 For repair parts, phone 1-800-654-3545. 15 18 17 13 18 30 28 24 5 4 27 23 21 22 7 29 8 25 19 10 9 26 20 12 11 10
Inhaltszusammenfassung zur Seite Nr. 11
11 Repair Parts List 52” “APOLLO” Series Models Ref. No. Description CF3900WW01 CF3900AB01 CF3900PB01 CF3900WPB01 CF3900OB01 CF3900HTW01 CF3900BS01 CF3900BQ01 CF3900TG01 CF3900AW01 CF3900CK01 Hanger Pack, 761655 761655-3 761655-2 761655 761655-9 761655-12 761655-17 761655-19 761655-13 761655-21 7616551-23 containing: 1 Bracket, Hanger (1) — — — — — — — — — — — 2 Hanger Ball Assembly (1) — — — — — — — — — — — 3 Downrod (1) — — — — — — — — — — — 6 Cover, Ceiling 761620 761620-3 761620-2 761620 761
Inhaltszusammenfassung zur Seite Nr. 12
! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch switch wire connections in the switch housing. wire connections in the switch housing. ! WARNING: Make sure main