Inhaltszusammenfassung zur Seite Nr. 1
Ventilating Fan
Model No. FV-11VH2
FV-11VHL2
FV-11VH2 FV-11VHL2
Thank you very much for having purchased our Ventilating Fan.
I
II
III
Maintenance (Cleaning) I
Maintenance (Replacement of lamp) II
back cover
back cover
Inhaltszusammenfassung zur Seite Nr. 2
UNPACKING Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. SUPPLIED ACCESSORIES FOR MODEL FV-11VH2 FOR MODEL FV-11VH2 POURLE MODELE FV-11VHL2 POURLE MODELE FV-11VHL2 DESCRIPTION The Panasonic ceiling mount ventilating fans uses a sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal cut-off for safety. The grille cover
Inhaltszusammenfassung zur Seite Nr. 3
DIMENSIONS 19 1/2 (497) 16 (407) 18 1/8 (460) 5 (128.7) 7 5/8 (195) 19 1/2 (497) 16 (407) 18 1/8 (460) 5 (128.7) 7 5/8 (195) Ventilating unit 2 1/2 (62) 2 1/2 (62) 7 3/4 (196) 7 3/4 (196) 11 7/8 (301) 11 7/8 (301) 2 1/8 (54.8) 1 (25) 14 (357.8) 13 1/4 (337.8) 11 1/4 (285.5) 11 1/4 (285.5)
Inhaltszusammenfassung zur Seite Nr. 4
SPECIFICATIONS Noise Vent (0.1" WG) Vent (cfm) (sone) 15.6 650 0.6 (7.1) Exhaust & 29.5 1540 Circulation 17.8 720 0.7 (8.1) GENERAL SAFETY INFORMATION AC 120V, 60Hz. 8. Make sure that all duct work is properly vented. 9. DO NOT INSTALL THIS UNIT OVER A BATHTUB OR SHOWER ENCLOSURE. 10. This product (FV-11VHL2) has a fluorescent lamp that contains mercury. Disposal may be regulated in your community due to environmental considerations. For disposal or recycling information, please conta
Inhaltszusammenfassung zur Seite Nr. 5
GENERAL SAFETY INFORMATION CONTINUED WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Neither unauthorized modification, repair nor disassembly is allowed.
Inhaltszusammenfassung zur Seite Nr. 6
INSTALLATION (JOIST MOUNTING- ) Illustrations in this manual common use the image of Suspension FV-11VHL2, and mark for FV-11VHL2 only, others are bracket same for FV-11VH2. 1. Before installation, remove warning lable and the tape that is securing the adapter and the damper. (Fig.1) Warning label Fan body Suspension Tape Fig.2-1 bracket Suspension Suspension bracket bracket Fan body Fig.1 2. Insert the suspension bracket into the fan body. (Select the suspension bracket as show
Inhaltszusammenfassung zur Seite Nr. 7
17 3/8 (441) INSTALLATION (JOIST MOUNTING- ) CONTINUED 5. Remove the lighting cord out from hook (FV-11VHL2), Screw driver Lighting cord Junction box then remove junction box plate and secure conduit or plate stress relief to wiring box knock-out hole.(Fig.5) 6. Refer to wiring diagram (Page.5) Follow all the local electrical safety codes. As well as the National Electrical Code (NEC). Screw Using UL approved wire nuts, connect house power Hook wires to
Inhaltszusammenfassung zur Seite Nr. 8
INSTALLATION (BETWEEN JOIST MOUNTING) Illustrations in this manual common use the image of FV-11VHL2. Suspension bracket 1. Before installation, remove warning lable and the tape that is securing the adapter and the damper. (Fig.1) Fig.11 (Select the suspension bracket according to spacing A as shown below.) Fan body Suspension Suspension bracket bracket B Fig.11 Joists Spacing A on center joists B 16 inches 13 1/4 ~ 15 1/2 (336~394) 19.2 inches horizontal joists 14 3/4 ~ 16 3/4 (374~4
Inhaltszusammenfassung zur Seite Nr. 9
11 3/8 (290) INSTALLATION (BETWEEN JOIST MOUNTING) CONTINUED Fig.13, Fig.14 Joist 2 Long screws (ST4.2X20) Fig.13 2-Screw 4 Long screws Fig.14 (ST4.2X12) (ST4.2X20) Joist 6. Follow step 5 of installation (page 7) to complete the installation work. Fig.14 INSTALLATION (WOODEN HEADER INSTALLATION) 1. Before installation, remove warning lable and the tape that is securing the adapter and the damper. (Fig.1) Ceiling joist Header Ceiling joist Adaptor (Fig.15, Fig.16) Fan body Fig
Inhaltszusammenfassung zur Seite Nr. 10
MAINTENANCE (CLEANING) Slot Mounting spring Gloves 1 Grille Do not allow any water to get into the motor. 1 oo 60C(140F). 2 Fig.17 Fig.17 Fig.18 Fig.18 Fig.19 Fig.19 Vacuum cleaner Fig.20 5. Replace grille. Fig.20
Inhaltszusammenfassung zur Seite Nr. 11
MAINTENANCE (REPLACEMENT OF LAMP) 4. Be sure to remove the night lamp before removing fluorescent lamps. (Fig.17 of page 10) 2. Remove the 4 W night lamp.(Fig.21) Fig.21 Night lamp Fluorescent lamp 3. Change the fluorescent lamps (FDS18E35/4, 18 W) (Fig.22) or the 4 W night lamp(Fig.21), replace the grille. Fluorescent lamp Fig.22
Inhaltszusammenfassung zur Seite Nr. 12
PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to Fig.23 Dryer-hood type vent with backdraft flap (s). Caulk termination to duct. 2-3 ft straight run before elbow. In attic installation, caulk box to drywall. Short piece of flexible duct helps alignment and absorbs Insulation sound. Use clamps plus tape at all flex joints. Foil tape tightly covers all metal duct joints (glue PVC joints). Fig.23 PANASONIC CONSUMER ELECTRONICS COMPANY Division de Panasonic Corporation