Inhaltszusammenfassung zur Seite Nr. 1
®
XP-400 & RPXP4GT keypad
Control Panel/Communicator
Installation Instructions
WI1370 1/05
© NAPCO 2005
Inhaltszusammenfassung zur Seite Nr. 2
WI1370 XP-400 Installation Instructions Table of Contents General Information XP-400 Features General Information ........................................... 2 Control Panel The NAPCO EXPRESS XP-400 control panel XP-400 Features ............................................... 2 •4 Zones provides up to 4 hardwired/wireless zones. Up to four Specifications .................................................... 3 4-digit user codes can be programmed. Ambush, •3 Keypad Panics List
Inhaltszusammenfassung zur Seite Nr. 3
Specifications Loop Characteristics Current & Voltage Ratings Loop Voltage: --------------------------5 Volts Alarm Output -------------------------- Burg: 12 VDC, 2A (max.) Loop Current : --------------------------Zones 1, 2: 0.9 mA (2.2 K) Output Current Limiting -------------- Burg: 2.25 A Zones 3, 4: 0.5 mA (3.9 K) AUX Power: 750 mA Loop Resistance: ----------------------100Ω per zone (max.) Residential Burglary (4 Hour Standb
Inhaltszusammenfassung zur Seite Nr. 4
WI1370 XP-400 Installation Instructions Optional Accessories Listings and Approvals GEM-RECV-XP8: *Wireless Receiver UL HOUSEHOLD BURGLARY WARNING SYSTEM CONTROL UNIT GEM-TRANS2 Window/Door Transmitter STANDARDS # 1023 GEM-KEYF: Key Fob Transmitter GEM-PIR: Wireless PIR VERIFIED TO COMPLY WITH F.C.C. PART 15 AS CLASS B : DIGITAL DEVICE GEM-DT: Wireless Dual-Technology Sensor GEM-GB: Wireless Glass-Break Detector European E.M.C. Regul
Inhaltszusammenfassung zur Seite Nr. 5
also be automatically downloaded/uploaded 4. Site-Initiated (PCPreset & A6) Programming the Panel using PCD2000 Software running PCPreset. 5. Automatic Downloading (Using PCPreset) Refer to XP-400 Programming Instructions (WI1371) For Site Initiated Downloaded, see Auto Defaulting the Panel Download ID Number [93]. 1. Remove power from the panel. Local Downloading 2. Remove all wiring from terminal 15 (PGM) Wire as shown in Figure 1. Use the power up or and terminal 3.
Inhaltszusammenfassung zur Seite Nr. 6
WI1370 XP-400 Installation Instructions and a Z (3.9 K) type Zone Doubling Resistor for Installation Wiring the secondary zone. Grounding the Panel Mounting the Panel Terminals 2.2 K Primary 3.9 K Connect the control-panel EARTH GROUND Mount the Panel close to an unswitched AC screw to a metal cold-water pipe. Do not use a source, a cold-water pipe ground, and a 3&4 Zone 1 Zone 4 gas pipe, plastic pipe or AC ground connections. telephone line connection. 5&4 Zone 2 Zo
Inhaltszusammenfassung zur Seite Nr. 7
PGM Wiring 1 SECOND - STEADY TONE ZONE LED DEFINITION The PGM is a switched negative output that is Incorrect Code Entered Faulted Zone ON activated depending on the programming option Invalid key entry Bypassed Zone Slow Flash (s) that have been selected [08], [23] - [25]. Zone in Alarm Flashing Connect the device controlled by the PGM 4 LONG BEEPS (PRIORITY CONDITION) between +PWR and the PGM terminal
Inhaltszusammenfassung zur Seite Nr. 8
WI1370 XP-400 Installation Instructions Ready and HSYSTEM TRBL LEDs are out Arming/Disarming with a Keyfob Arming/Disarming with a Keyswitch The system can be armed by pressing the K The system can be armed/disarmed by using a indicating: momentary Keyswitch wired to . Program Zone 4 key, and disarmed by pressing the L key on Keyfob/Keyswitch Chirp [23-4] for an audible The system is displaying Alarm Memory. the Keyfob. Zones programmed as Exit/Entry indication of system arming and
Inhaltszusammenfassung zur Seite Nr. 9
bypassed zone LED will flash slowly; indicating Full Setting the System with Automatic User Program Mode the zone has been bypassed. While the panel is Bypassing - Home/Away with Delay ARMED, the bypassed zones will only be Zones To prevent the loss of the User 1 Code, the displayed if the Display Bypassed [21-3] option panel default program includes User 1 Code has been selected. Lockout [96-2]. From the Keypad To change the User 1 Code from its default Press C B to return
Inhaltszusammenfassung zur Seite Nr. 10
WI1370 XP-400 Installation Instructions A 5 Chime ON/OFF Zone LED Meaning XP-600 Commands Enter this command to turn chime ON/OFF. User Arm/Disarm Code not programmed OFF The Keypad will chime on any zone that has not User Commands been selected as an Exit/Entry Follower Zone, User Arm/Code is currently being programmed Flashing Home/Away with Delay Zones, or 24 Hour Zone. A 1 Bell Test User Arm/Disarm Code has been programmed Steady Enter this command to tur
Inhaltszusammenfassung zur Seite Nr. 11
of 4 to 10, with 4 being marginal and 10 being Dealer Commands Zone Features excellent. A6 Download (Programming [00]Exit/Entry Zones The keypad will beep out a number, from 1-4, Required) Delay allows exit and entry through an Exit/ corresponding to the signal strength of the Establish a connection between the PCD phone Entry Zone after the system is armed transmitter. See Table 5 below. Each beep is 1- line and the Control Panel phone line. When without setting off an immedia
Inhaltszusammenfassung zur Seite Nr. 12
3.9K 2.2K WI1370 XP-400 Installation Instructions To eliminate this fixed 20-second entry Auto Interior Bypassing - Also program zones [06]Open Circuit Zones delay, also program zones as Exit/Entry as Home/Away with Delay Zone(s) [01] to Program this zone type if unsupervised Follower Zones [02]. automatically bypass at the expiration of the exit normally open circuit devices are required To return protection to zones of this type, delay if the EXIT/ENTRY Zone(s) are not The prog
Inhaltszusammenfassung zur Seite Nr. 13
may be canceled by pressing a4 before a trip or a status) from a transmitter in the [08]PGM Output time specified, a system trouble RF Enables the PGM Output on a zone trip for or after arming. Supervisory Failure' will be indicated at the each zone selected. The PGM Output will keypad. Timer is programmable from 1-26 remain ON until reset. [12]Burg (Steady) Output Time-out hours; 0 means NO supervision. Can be programmed from 1 to 255 min (4¼ System Times hours); 0 means o
Inhaltszusammenfassung zur Seite Nr. 14
WI1370 XP-400 Installation Instructions enables Easy Arm, enter a0 to arm (2) Access Output - Activates the PGM [21]Keypad Features 2 output for 5 seconds using the A3 (1) Audible Panic - Keypad Panic will not the system. turn the Bell on unless this option is (3) Swinger Shutdown - Automatically command. programmed. disables armed zones with excessive alarm/ (3) Follow Keypad Sounder - The following (2) Exit/Entry with Urgency - select to give restores (swingers). Non-24-Hour keypa
Inhaltszusammenfassung zur Seite Nr. 15
(3) Panic - Program to activate the PGM on (2) Reserved. not required for Telco 1, Telco 2 and Telco a Panic alarm. (3) Inhibit Fail-to-Communicate Display - 3. If dial tone detection is not desired select (4) Test Timer - Program to activate the This option prevents the keypad from either No Dial Tone Detection in Communicator PGM during a Test Timer report. indicating or sounding when a Fail to Features [46-1]. Use the i key to blank Communicate has occurred. out remaining digits in t
Inhaltszusammenfassung zur Seite Nr. 16
WI1370 XP-400 Installation Instructions (3) Single Digit - 3/1 Format. 3-digit [33] - Select Pager Extend 000 033-1234 Subscriber ID number and a 1-digit Alarm [41] - D D D X X X X X X X C 0 Leading Digits Code will be transmitted. Report Code (4) No Handshake/Pager Extend - The Delay Leading 0 meaning of this option is dependent on Subscriber ID Number PIN Number Terminating Digit (#) Receiver Format programming. FIGURE 7 DEFAULT PAGER DISPLAY No Handshake (All
Inhaltszusammenfassung zur Seite Nr. 17
[37]System Reporting, Telco 1 [45]Communicator Features 1 Backup Telephone Programming (1) Communicator Enabled - Program to (1) Y AC Fail Report - Program to activate an enable the communicator. [40]Subscriber ID Number (Telco 2) AC Fail report (15 minute fixed report delay). (2) DTMF with Rotary Backup - The first For 4/2 format enter a 4 digit number. If 3/1 (2) Low Battery Report - Program to attempt to communicate is dialed using the format is required enter a 3 digit number
Inhaltszusammenfassung zur Seite Nr. 18
WI1370 XP-400 Installation Instructions [61]Point ID Report Codes [63]System Report Codes Point ID Report Codes are defaulted to Program a 2-digit report code for Keypad Telephone Number 3 Programming Burglary for zones 1 through 4. Optionally, Panic 2, Keypad AUX, Keypad Panic, Test Point ID codes for zones 1 through 4 can be Timer, AC Fail, Low Battery and Trouble. [50] - [59] programmed as follows: Programming is the same as for Telco 1. [64]System Restore Code Program
Inhaltszusammenfassung zur Seite Nr. 19
A transmitter will send a transmission every [66]Ambush Report Code [68]Telephone Number 3 time it is tripped. The transmitter also sends Program a 2-digit report code for Ambush. (1) Opening after Alarm (Cancel Code) - a supervisory transmission about once To send an ambush report, program a User see [67-1]. every hour. If the receiver does not receive Code for User 4, Program report User 4 as (2) Conditional Closing Telco 3 - see [67- a signal from a transmitter in the time Ambush [
Inhaltszusammenfassung zur Seite Nr. 20
WI1370 XP-400 Installation Instructions Enter the RF ID# and AUX 1 and AUX 2 3 Bell ON [71-74] Wireless Transmitters options for each Keyfob. Program a 3 in the AUX 1 and/or AUX 2 Enter the RF ID# and the point number that option to turn the Bell ON when the M or is to be mapped to the zone. AUX 1 & AUX 2 N buttons on the Keyfob are pressed. Programming Options: Programming Example Press the L button to turn the Bell OFF. Map point 1 of a window door transmitter 1 Panic w