Inhaltszusammenfassung zur Seite Nr. 1
80 Series Thermostat with
Automatic Heat/Cool Changeover Option
Single Stage or Heat Pump
Installation and Operating Instructions for Model:
Save these instructions for future use!
Model Programming Choices
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
1F80ST-0471 5/2 Day 5/1/1 Day Non-Programmable
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
1F86ST-0471 Non-Programmable
PROPERTY DAMAGE.
APPLICATIONS
1F80ST-0471 Thermostat
THERMOSTAT APPLICATION GUI
Inhaltszusammenfassung zur Seite Nr. 2
INSTALLATION Batteries WARNING ! 2 "AA" alkaline batteries are included in the thermostat. To in- Thermostat installation and all components of the control stall the batteries, pull the battery door as shown by the arrow system shall conform to Class II circuits per the NEC and lift open. Using the polarity indicated inside the battery code. door, insert the batteries. To close the battery door, swing the door down while pulling in the direction of arrow. Once fully down, snap the door back
Inhaltszusammenfassung zur Seite Nr. 3
WIRING CONNECTIONS Refer to equipment manufacturers' instructions for specifi c system wiring information. After wiring, see CONFIGURATION section for proper thermostat confi guration. Refer to 37-6754 for 1F80-0471/1F86-0471 wiring diagram specifi cations. TERMINAL DESIGNATION DESCRIPTIONS Designation Description Designation Description Terminal Terminal O/B................. (SS) Power closed for 3 wire zone RH...................Power for Heating (HP) Changeover valve for heat pump RC..........
Inhaltszusammenfassung zur Seite Nr. 4
INSTALLER/CONFIGURATION MENU Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press or to change a menu item. Shaded items are not available on 1F86. INSTALLER/CONFIGURATION MENU Press or to MENU PRESS DISPLAYED select from listed options REF HP SS BUTTON (FACTORY DEFAULT) COMMENTS 1 1 MENU On (Frio O) Calor b On Reversing Valve Output (SS/HP switch must be in the Heat Pump HP position) 2 2 1 MEN
Inhaltszusammenfassung zur Seite Nr. 5
INSTALLER/CONFIGURATION MENU 4. Energy Management Recovery: (this step is skipped if 9. System Mode Confi guration – This thermostat is confi gured to be non-programmable). confi gured for Calor and Frio with Auto changeover (SISTEMA switch with Frio Off Calor Auto) default. It can Energy Management Recovery (E) On enables the also be confi gured for Calor and Frio (Frio Off Calor), thermostat to start heating or cooling early to make the Calor only with fan (Off Calor), Calor only witho
Inhaltszusammenfassung zur Seite Nr. 6
OPERATING YOUR THERMOSTAT IMPORTANT! Choose the Vent Setting (Auto or On) Manual Operation (Bypassing the Program) Programmable Thermostats Set the VENT Switch to Auto or On. Press or and the Retener button and adjust the Vent Auto is the most commonly selected setting and runs temperature wherever you like. This will override the program. the fan only when the heating or cooling system is on. The Retener feature bypasses the program and allows you Vent On runs the fan continuously for i
Inhaltszusammenfassung zur Seite Nr. 7
PROGRAMMING (For Programmable Model Only) Energy Saving Factory Pre-Program The 1F80ST-0471 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the Arrancar button. The table below shows the factory set heating and cooling schedule for all days of the week. Wake Up Leave For Work Return Home Go To Bed (Period 1) (Period 2) (Period 3) (Period 4) Heating 6:00 AM 7
Inhaltszusammenfassung zur Seite Nr. 8
TROUBLESHOOTING Reset Operation Note: When thermostat is reset, installer confi guration menu settings and programming will reset to factory settings. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermo- stat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and s