Inhaltszusammenfassung zur Seite Nr. 1
E
V
O
T
S
C
S
O
E
M
T
OWNERS MANUAL
Models B2350 and B2350B
Wonderluxe
THERMOSTAT CONTROLLED DUAL FUEL CIRCULATOR SERIES
• ASSEMBLY
• INSTALLATION
• OPERATION
• REPAIR PARTS
Tested To:
UL 1482 - 06 &
ULC S627-00
Fold Here Fold Here
Ê É
Place SAFETY NOTICE:
StamP
If this heater is not properly installed, a house fire may result.
Here
To reduce the risk of fire, follow the installation instructions.
Contact local building or fire officials about permits, restrictions
and inspection requirements
Inhaltszusammenfassung zur Seite Nr. 2
TOOLS AND MATERIALS NEEDED TOOLS MATERIALS WARRANTY INFORMATION CARD • Pencil • Chimney Connection- 6” Diameter Black Steel pipe (24 gauge minimum) and elbow(s) either • Measuring Tape or 6 foot rule Name___________________________________________________ Telephone #: (_____) ___________ 1 adjustable or corrugated as necessary • Tin Snips • 1/2” Sheet Metal Screws City ________________________________________________State__________Zip ___________________ • Drill and 1/8” dia. bit • 6” Inside
Inhaltszusammenfassung zur Seite Nr. 3
E V O T S C S O E M T 8. CAST IRON PARTS MUST BE “SEASONED” TO when heater is not hot. DO NOT use any harsh HOW TO ORDER REpAIR pARTS AVOID CRACKING. BUILD ONLY SMALL FIRES chemicals (acids or caustics) or scouring ON FIRST USE. powder, as these wear and dull the finish. 9. To prevent injury, do not allow anyone to use 13. KEEP THE FEED DOOR, ASH DOOR AND CABINET this heater who is unfamiliar with the correct DOOR CLOSED AT ALL TIMES EXCEPT WHILE This manual will help you to obtain efficie
Inhaltszusammenfassung zur Seite Nr. 4
LOCATINg THE HEATER NOTES AS A LOCATION IS SELECTED, KEEP THE FOLLOWING MIND: 1. The chimney connection should be as airtight in./ft. 2 hr. Deg. F with 28-gauge sheet metal as possible. The heater must have its own or a UL Listed floor protector. Have the floor chimney flue. Do not connect this unit to a protector extend 16" beyond the door side chimney flue serving another appliance. If of the heater and under the connector pipe there is no chimney near where you wish to in the back. plac
Inhaltszusammenfassung zur Seite Nr. 5
Your smoke pipe should be assembled in CHIMNEY CONNECTION ExTERNAL pARTS DIAgRAM/LIST such a way that the male section (crimped Two basic types of chimneys are approved end) of the pipe faces down. This will allow for use with solid fuel: Factory-built and ma- condensation in the flue to run back into the sonry. Factory-built chimney must comply heater. Attach each of the sections to one 12 with UL 103 type “HT” standard. another with three equidistant metal screws Do not expect your sto
Inhaltszusammenfassung zur Seite Nr. 6
CHIMNEY pARTS LIST Your wood stove may be hooked up with a The following recommendations may be Key part No. Description Qty. 6” factory built or masonry chimney. If you useful for the installation of your chimney: 1 67859 Weldment, Base 1 are using a factory built chimney, it must 1. It must rise above the roof at least 3’ 2 22030 Shield, Second Heat (Included w/ 67859) 1 comply with UL 103 standard; therefore it (0.9m) from the uppermost point of must be a Type HT (2100°F). It is extremel
Inhaltszusammenfassung zur Seite Nr. 7
INTERNAL pARTS DIAgRAM FACTORY bUILT CHIMNEY When a metal prefabricated chimney insulation shield, roof flashing, chimney is used, the manufacturer’s installation cap, etc. Maintain proper clearance to instructions must be followed. You must the structure as recommended by the also purchase (from the same manufac- manufacturer. The chimney must be the turer) and install the ceiling support pack- required height above the roof or other age or wall pass-through and “T” sec- obstructions fo
Inhaltszusammenfassung zur Seite Nr. 8
vENTINg INTO A FIREpLACE MAINTENANCE Many people may wish to convert an existing heater is being vented into another appli- DISPOSAL of ASHES fireplace to heater use. Usually, safe con- ance - the fireplace. This method should not Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches CAUTIONS: nection of stovepipe to a masonry chimney be attempted because combustion products deep. Always empty the stove when it is cold, requires more effort than connection
Inhaltszusammenfassung zur Seite Nr. 9
bULLETINE RC454 continued... to a near closed position - but leave the ash BANKING THE FIRE: pit damper at least partially open to prevent For extended operation, such as overnight, the the fire from going out. Adjust the stove pipe fire will need to be banked. To do so heap coal damper to reduce the draft on the fire. With an- up along the sides and back of the firebox so thracite there will be short blue flames above that the fire gradually burns it over a longer the coal, except when
Inhaltszusammenfassung zur Seite Nr. 10
MASONRY CHIMNEY continued... bULLETINE RC454 A guide to burning coal in your heater. Ensure that a masonry chimney meets the Have the chimney cleaned before the Heaters that are capable of burning coal usu- to the center of the firebox forming the cone. minimum standards of the National Fire stove is installed and operated. When ally will burn both Bituminous and Anthracite Burning in this fashion allows heat to drive off Protection Association (NFPA) by having connecting the stove through
Inhaltszusammenfassung zur Seite Nr. 11
Operating Instructions Combustible Wall Chimney Connector pass-Throughs 1. Always set the thermostat to high before opening FUEL RECOMMENDATIONS ment the clay liner in place to the chimney flue the feed door to refuel or stoke the fire. WOOD liner. 2. When opening the feed door, turn handle and open Hardwood, 18” to 23” log should be split and air Method B. 9” (228.6 mm) Clearance to Combus- door until it stops on the latch and leave it at that dried (seasoned) for 6 months to obtain maxi
Inhaltszusammenfassung zur Seite Nr. 12
CAbINET DOOR KNOb ASSEMbLY INSTRUCTIONS FOR TWO-STEp LATCH OpERATION Follow these instructions to operate you unit safely when operating the feed door. The cabinet door knob is mounted on the FOLLOW THESE INSTRUCTIONS FOR DOOR inside of the cabinet door to facilitate KNOB ASSEMBLY: 1. Turn handle clockwise to the 12 o'clock 3. Then to open door, turn the handle shipping and must be removed and re- 1. Remove the machine screw and the position (A), pull the door open until you counter clockwise