Inhaltszusammenfassung zur Seite Nr. 1
TEC Electronic Computing Scale
SL-9000/9000N-FFB SERIES
Owner’s Manual
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
Safety Summary Safety Summary Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautions necessary for safe handling are included in this manual. All warnings and cautions contained in this manual should be read and understood before handling or maintaining the equipment. Do not attempt to effect repairs or modifications to this equipment. If a fault occurs that cannot be rectified using the procedures described in this manual, turn off the power, u
Inhaltszusammenfassung zur Seite Nr. 4
Safety Summary Disconnect Disconnect If foreign objects (metal fragments, When unplugging the power cords, the plug. the plug. water, liquids) enter the machines, be sure to hold and pull on the plug first turn off the power switches and portion. Pulling on the cord portion disconnect the power cord plugs from may cut or expose the internal wires the outlet, and then contact your and cause fire or electric shock. authorized TOSHIBA TEC repre- sentative for assistance. Continued use of the
Inhaltszusammenfassung zur Seite Nr. 5
TABLE OF CONTENTS Page 1.INTRODUCTION ............................................................................................. 1-1 1.1 APPLICABLE MODEL ........................................................................... 1-2 1.2 ACCESSORIES .................................................................................... 1-2 2.SPECIFICATIONS ........................................................................................... 2-1 2.1 SCALE................................
Inhaltszusammenfassung zur Seite Nr. 6
Page 12.PROGRAMMED DATA VERIFICATION REPORTS ....................................... 12-1 13.PASSWORD SECURITY ................................................................................. 13-1 13.1 SETTING PASSWORD AND PROTECT MENU................................... 13-1 13.2 CALLING MENU BY ENTERING PASSWORD .................................... 13-3 14.OPERATING PROCEDURES ......................................................................... 14-1 14.1 WEIGHING OPERATION ...............
Inhaltszusammenfassung zur Seite Nr. 7
Inhaltszusammenfassung zur Seite Nr. 8
EM1-31064 1. INTRODUCTION 1. INTRODUCTION 1. INTRODUCTION Thank you for purchasing the TEC SL-9000 Series electronic computing scale. As you will discover, the TEC SL-9000 series has many features and functions designed for user friendliness as well as complete customer satisfaction. The 256 x 64 dot fluorescent display provides customers with ample information, the 140 speed keys realize a higher degree of operability, and the 3 inch/sec. print speed ensures fast and clear printing. Password s
Inhaltszusammenfassung zur Seite Nr. 9
EM1-31064 1. INTRODUCTION 1.1 APPLICABLE MODEL 1.1 APPLICABLE MODEL • SL-9000-15M-FFB-CA • SL-9000-30M-N-FFB-US • SL-9000-15M-FFB-QR • SL-9000-15M-N-FFB-CA • SL-9000-15M-N-FFB-QR The description of the model number is as follows. S L - 9 0 0 0 - 3 0 M - N - F F B - U S Destination Code Max. Capacity ex.) US, CA, QR etc. 30M: 30 lbs (decimal Keyboard Type pound/multi-interval) B: Built-in keyboard 15M: 15 Kg (multi-interval) Display Type FF: Fluorescent full dot display N: LAN (option) is availab
Inhaltszusammenfassung zur Seite Nr. 10
EM1-31064 2. SPECIFICATION 2.1 SCALE 2. SPECIFICATION 2.1 SCALE Item US CA QR Maximum Capacity 30 lb 15 Kg (30 lb) Minimum Scale Division 0.005 lb (0~15 lb) 0.002 Kg (0 ~ 6 Kg) 0.005 Kg (6 ~ 15 Kg) 0.01 lb (15~30 lb) 0.005 lb (0 ~ 15 lb) 0.01 lb (15 ~ 30 lb) Maximum Tare 2.000 lb 1.000 Kg (2.205 lb) Display Range 0 ~ 30.05 lb 0 ~ 15.025 Kg (0 ~ 30.05 lb) Unit Price Presettable $0.01 ~ 99.99 $0.01 ~ 99.99 0 ~ 99999 Minimum Price Display $0.01 $0.01 1 Power Requirement AC 120 V – 10%, 60 Hz (US/CA
Inhaltszusammenfassung zur Seite Nr. 11
EM1-31064 2. SPECIFICATION 2.2 OPTION 2.2 OPTION Model No. Option Name Description Source or Part No. LON Connector Part No. A modular connector used to connect scales See TM8P-88P EAJ-0028001 to each other in a LON configuration. Note 2 LON Terminal Part No. A modular resistor attached to the scales See Resistor 285D-8P EAJ-0029001 connected at both ends of the LON Note 2 LON configuration. Part No. LON Cable An 8-pin telephone cable used with the LON 10319100003 S-STLAN-2P connectors att
Inhaltszusammenfassung zur Seite Nr. 12
EM1-31064 3. APPEARANCE 3. APPEARANCE 3. APPEARANCE LAN I/F (SL-9000N Option) PC-AT Keyboard I/F (Option) Main Power Switch Drawer I/F (Unused) Remote Display Meat Platter CMT/PL-3 I/F LON I/F Right Cover Power Cord Speed Keyboard and Adjustable Legs Programming Keyboard Operation Keyboard Level Gauge Print Head TMCC I/F: MALE (Option) 3-1
Inhaltszusammenfassung zur Seite Nr. 13
EM1-31064 4. DISPLAY 4.1 US TYPE 4. DISPLAY 4.1 US TYPE WEIGHT e=d SCROLLING MESSAGE INDICATES CAPACITY SL-9000N 0 ~ 15 lb 0.005 lb SCALE AT ZERO 15 ~ 30 lb 0.01 lb 4.2 CA/QR TYPE WEIGHT e=d WEIGHT e=d CAPACITY SL-9000N 0 ~ 6 Kg 0.002 Kg 0 ~ 15 lbs 0.005 lbs CAPACITÉ 6 ~ 15 Kg 0.005 Kg 15 ~ 30 lbs 0.01 lbs NOTE: For the SL-9000 model, the model name on the display panel is "SL-9000". 4-1
Inhaltszusammenfassung zur Seite Nr. 14
EM1-31064 5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD 5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD SET NEXT AUTO CLEAR SHIFT NEXT PLU CODE CHANGE DELETE RETURN SEND RECEIVE ↑ ↓ PLU PLU 1/4 DELETE INSERT DELETE PROG. ENTER - TEST ← → (A) 1 (B) 1/2 ! " # $ % & ´ ` ? @ 1 2 3 4 5 6 7 8 9 0 * + ( ) / : ; < > = Q W E R T Y U | O P [ \ ] ˆ - { } ~ A S D F G H J K L - È É Â Ê → ← ↓ ↑ . Z X C V B N M SPACE , ZERO FEED NOTE: Blank keys have no function. Programming Keyboard Function Function Name of Key 1. Clears n
Inhaltszusammenfassung zur Seite Nr. 15
EM1-31064 5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD Function Name of Key 1. Displays the preceding PLU data. _ 2. Used for setting an auto code. 3. Calls the preceding label format # when setting the print position. Moves the cursor to the left. ← Moves the cursor to the right. → DELETE 1. Deletes the character selected by the cursor when setting commodity (A) name or message. 1/2 2. Sets a unit price per 1/2 lb. 1. Inserts a space at the cursor position when setting a commodity name or INSERT 1 me
Inhaltszusammenfassung zur Seite Nr. 16
EM1-31064 5. KEY LAYOUT 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD 1 Primary function CA, QR US type type 2 Secondary function 1 1/2 100 g 2 1/4 LB/kg 1 2 3 4 5 6 7 8 9 1 ESC. PROG. POWER 10 11 12 13 14 15 16 17 18 NEXT VOID 2 PLU 19 20 21 22 23 24 25 26 27 PRESET SAVE FOR DT/TM COUNT 28 29 30 32 32 33 34 35 36 GRADE 78 9 LINE 37 38 39 40 41 42 43 44 45 45 6 LOGO 46 47 48 49 50 51 52 53 54 12 3 GROUP# 55 56 57 58 59 60 61 62 63 ST 0 TC 64 65 66 67 68 69 7
Inhaltszusammenfassung zur Seite Nr. 17
EM1-31064 5. KEY LAYOUT 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD Operation Keyboard Function Function Name of Key Prints a customer label. PRT/* Saves tare and unit price after taking off the commodity from the platter. SAVE Sets the quantity of a commodity in "BY COUNT" mode. FOR Displays the date. DT/TM Selects the item for change Print/OFF. NEXT PLU Corrects data just after the registration. VOID 1. Enables calling the other 70 speed keys. 2. Selects the function for change Print/OFF. Retur
Inhaltszusammenfassung zur Seite Nr. 18
EM1-31064 5. KEY LAYOUT 5.3 SELF SERVICE KEYBOARD Name of Key Function No function GROUP # No function ST This key is used for item or subtotal discount by entering a percentage. % (Optional key by initial setting) Feeds the label. FEED Issues a test label. TEST Adjusts the zero point. ZERO Changes the label issue mode between automatic issue and manual AUTO/ issue. (Optional key by initial setting) MANUAL 1 70 Calls the assigned PLU. to 5.3 SELF SERVICE KEYBOARD X X X X ESC. X POWER 1 2 3 PUSH
Inhaltszusammenfassung zur Seite Nr. 19
EM1-31064 5. KEY LAYOUT 5.3 SELF SERVICE KEYBOARD (For Programming/Unit-Price Change/Read Reset/Security) SET NEXT AUTO CLEAR SHIFT ESC. PROG. POWER NEXT PLU CODE CHANGE DELETE RETURN NEXT SEND RECEIVE ↑ ↓ VOID PLU PLU 1/4 PLU DELETE INSERT DELETE PROG. ENTER - TEST ← → (A) SAVE FOR DT/TM 1 (B) 1/2 ! " # $ % & ´ ` ? @ 78 9 1 2 3 4 5 6 7 8 9 0 * + ( ) / : ; < = > 45 6 Q W E R T Y U | P O [ \ ] ˆ - { } ~ 12 3 A S D F G H J K L - È É Â Ê → ← ↓ ↑ 0 TC . Z X C V B N M SPACE , PLU PRT/* ZERO FEED The
Inhaltszusammenfassung zur Seite Nr. 20
EM1-31064 6. PROCEDURE BEFORE OPERATION 6. PROCEDURE BEFORE OPERATION 6. PROCEDURE BEFORE OPERATION 1. Unpack the accessories and scale from the carton. 2. Install the remote display on the scale. (See Page 7-1.) 3. Refer to Safety Precautions in this manual and set up the scale in a proper location. 4. Load the label or receipt. (See Page 9-1.) 5. Be sure to insert the power cord plug into an AC outlet. 6. Adjust the level gauge. (See page 8-1.) 7. Connect a PC-AT keyboard if necessary. 8. T