Inhaltszusammenfassung zur Seite Nr. 1
Mitsubishi Electric Air Conditioning Network System
Integrated centralized control software TG-2000A(Ver. 2)
Operation Manual (Site adjustment)
Contents
1. Safety Precautions................................1
2. System Requirements............................2
3. System Configuration.............................5
4. Flow of Site Adjustment..........................6
5. Installation .........................................9
6. Part Nam
Inhaltszusammenfassung zur Seite Nr. 2
Contents 1. Safety Precautions..............................................1 8.8 Watt Hour Meter Set-up................................40 8.8.1 Setting Procedures and Restrictions .........40 2. System Requirements..........................................2 8.8.2 Watt Hour Meter Setting (Step 1) ............40 2.1 Requirements (system recommendations)............2 8.8.3 Set-up for the Name and the Maximium 2.2 Compatible units..........................................2 Int
Inhaltszusammenfassung zur Seite Nr. 3
In this manual, Microsoft® Windows® 2000 Professional is called Windows 2000 and Microsoft® Windows® XP Professional is called Windows XP. In this manual, Microsoft® Excel 2000/XP is called Excel. Trademarks MS, Microsoft, Microsoft logo, and Windows are registered trademarks and trade names of Microsoft Corporation. Each company may use as registered trademarks and trade names the product names used in this manual. – Term description – • “Man-machine”:Indicates a personal comput
Inhaltszusammenfassung zur Seite Nr. 4
1. Safety Precautions • Please read the Safety Precautions section very carefully before using the unit. • The safety cautions provided here are very important for your safety. Please observe them at all times. • The degree of danger involved with incorrect operation of the unit are indicated in this manual using the following symbols. WARNING Incorrect operation could result in death or severe injury. CAUTION Incorrect operation could result in injury or damage to property.
Inhaltszusammenfassung zur Seite Nr. 5
2. System Requirements 2.1 Requirements (system recommendations) We recommend the following software and hardware when using this application (TG-2000A). Item Requirement Recommended PC PC/AT interchangeable machine Operation check completed, using IBM, COMPAQ, and DELL CPU Pentium III 350 MHz or faster : Pentium 4 1.8GHz or faster within 1000 indoor units Pentium III 1GHz or faster : 1001 indoor units or over Memory 128 MB or more 256 MB or more HD
Inhaltszusammenfassung zur Seite Nr. 6
2.3 Restrictions The following restrictions apply to the TG -2000A application. (1) System configuration limits Number of units Notes G-50A Max. 40 units G-50A Ver. 2.10 or higher Indoor unit Max. 50 units/G-50A Max. 2000 units (including all IC, KIC, AIC, LC, and FU) [Symbol]IC: Indoor unit, LC: LOSSNAY, FU: OA processing unit, AIC: “A” controller, KIC: “K” controller (2) Group setting restrictions Item Restrictions Note Remote controls 2 per group * Other remote controls besides
Inhaltszusammenfassung zur Seite Nr. 7
(7) Notes on charge system • If there is a group that is not set in the charge block, the electric power amount for that group will not be included in the air-conditioning charge. If there are groups which require charging to be divided, set those groups as operation blocks or charge blocks to accomplish this. • The air conditioning charge can be calculated by block units or by power meter units. Note that even when OA processing unit, LOSSNAY, A control unit or K control unit are included
Inhaltszusammenfassung zur Seite Nr. 8
3. System Configuration 3.1 System Configuration Example [Image drawing] HUB Outdoor unit Indoor unit Power supply unit LAN Remote Integrated software controller TG-2000 G-50A Power supply u nit G-50A 3.2 Hardware Connection Diagram (1) LAN connection Connect the LAN cable to the personal computer. For the location of the LAN connector for the personal computer, refer to the Instruction Manual of the personal computer. HUB 10BASE-T straight cable L
Inhaltszusammenfassung zur Seite Nr. 9
4. Flow of Site Adjustment 4.1 Flow of Site Adjustment When the task of site adjustment is subdivided into smaller tasks as shown in the figure below, the tasks can be broadly grouped into three steps. The benefit of following these three steps when carrying out the tasks of site adjustment is that if troubles do arise, it will be clear which step caused the problem. This makes it easier to solve problems and this results in a more efficient execution of site adjustment tasks. Carry
Inhaltszusammenfassung zur Seite Nr. 10
4.3 Step 1: Test operation from centralized controller G-50A Perform only the test operation of the air-conditioning system of the central controller G-50A. (1) Preliminary check Check that the test operation of the air conditioner has been completed. Check that the central controller G-50A is set to Group and Interlock. (The initial setting is executable using the initial setting tool or the G-50A.) HUB Power supply unit Integrated centralized control software G-50A
Inhaltszusammenfassung zur Seite Nr. 11
4.5 Step 3: Test operation from integrated centralized control software TG-2000A Perform the test operation from the integrated centralized control software TG-2000A to check the operation state and monitor display of the air conditioner. For the operation procedure, refer to the Instruction Manual (Management). Note: • For confirmation in the test operation, use the checklist shown in Chapter 11. • Perform the normal operation from the integrated centralized control software TG-20
Inhaltszusammenfassung zur Seite Nr. 12
5. Installation 5.1 Pre-installation Steps Preparing for installation Before installing the TG -2000A application, do the following checks and preparatory steps. Steps Action Details How to 1 Check the OS Check the OS Service Pack version. * If not the correct version, • Windows XP Professional refer to the attached • Windows 2000 Professional: SP2 documentation, “Installing and above • Windows 2000/XP” and upgrade the OS. 2 Check the memory Check that there is at least 128 MB
Inhaltszusammenfassung zur Seite Nr. 13
5.2.2 Running TG-2000A Setup (New setup) The TG-2000A setup is performed in three stages: Step 1) MSDE setup Step 2) Database setup Step 3) TG-2000A setup Note: • Perform the 3 setup steps sequentially. Otherwise, the TG-2000A will not operate properly. • Be sure to log-in to Windows, using the Auto log-in name and password before executing the set-up. (It is necessary to execute the log-in with a log-in name having administrator rights.) Step 1) MSDE setup Run the “MSDEIns
Inhaltszusammenfassung zur Seite Nr. 14
(2) Read the license agreement 1) Read the license agreement and click the [Next] button. The license agreement screens will be displayed one at a time. Carefully read all of the agreement and check that you agree with each item before selecting “It agrees” and clicking [Next] to continue. * If you cannot agree with the license agreement, click the [Cancel] button and stop the installation of TG-2000A. (3) Check the installation folder 1) Check the location where the prog
Inhaltszusammenfassung zur Seite Nr. 15
5.3 TG-2000A Uninstall This section describes how to uninstall an installed “MSDE” and “TG -2000A” program. (1) TG-2000A uninstall 1) Check to see if TG -2000A has ended Check to see if the TG -2000A program has ended. If it has not ended, end it. * For a description of the ending method, see Chapter 7. 2) Start “Add/Remove Programs”. Start by clicking Control Panel’s Add/Remove Pro- grams. 3) Select “TG-2000A”, and click [Change/Remove] button. Se
Inhaltszusammenfassung zur Seite Nr. 16
6. Part Names and Functions 6.1 Window Elements The window displayed when the power is turned on and no system settings have been made is called the Initial window. The Initial window has the following parts. (The Initial window can be accessed from the menu bar with a password. For details, see section 6.3.) Title bar: Shows the title of the window User setting group: Sets valid/invalid for the Menu bar: function, site name, and Shows a list of password. functions that may be
Inhaltszusammenfassung zur Seite Nr. 17
6.2 Basic Mouse Operation First, use of the mouse as a pointing device will be explained. If a device other than a mouse is being used, consult with the manual for that device. The following is a list of terms used in describing mouse operations. Click : This refers to pressing and releasing the button one time. To use this function, click the button Double Click: This refers to pressing and releasing the button twice in quick succession. Drag : This refers to moving the mouse pointer o
Inhaltszusammenfassung zur Seite Nr. 18
2) Enter the password Enter the word “*****” in the password verification box, then click the [OK] button. Doing so returns you to the initial window. There are two kinds of passwords. Initialization password: All the items in the initial window can be used. The Password input screen initial password is “SYSTEM”. Maintenance password: The initial window maintenance group and personal password can be changed. The initial password is “Maintenance”. Maint
Inhaltszusammenfassung zur Seite Nr. 19
[User setup group] Exit TG -2000A, shut Power On + Start TG-2000A down the OS, and turn the power off System data No system data Select [File]-[End] button [System setup group] Select [Exit] Password input button Return to Initial window * Range described in this manual Control window(Management screen) (see separate management manual) 16
Inhaltszusammenfassung zur Seite Nr. 20
Wizard name Primary settings contained in the activated window User Set -up Set TG -2000A functions Wizard name Primary settings contained in the activated window Site Name Set -up Set the product name (site name) Wizard name Primary settings contained in the activated window Password change Changes the password to the two types of Initial window Wizard name Primary settings contained in the activated window Preparation for the G-50A Checks the step/caution display for the G-5