Inhaltszusammenfassung zur Seite Nr. 1
Operation/Maintenance/Programming
1 2 3
S TE E L M EC P T N C I O SE N IR T P S UTA SH R T
1S TE E L M EC P T N C 2 I O SE N IR T P 3 S UTA SH R T
H G I H LOW H IGH LOW
TEMP STAR T TE MP TEMP STAR T TEMP
T M E ED MP H NE O A T T M E ED MP H NO EA T
25C 25C
Drying Tumblers
Refer to Page 3 for Model Numbers
NOTA: El manual en
T433I
español aparece después
T477C
del manual en inglés.
T478C
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompa
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code”. In Canada, installation must comply with Standards CAN1-B149.1 or CAN1-B149.2 codes for gas burning appliances and equipment and CSA C22.1, latest edition, Canadian Electric Code, Part I. In Australia, installation must comply with the Australian Gas Association Installation Code for Gas Burning Appliances and Equi
Inhaltszusammenfassung zur Seite Nr. 4
Introduction......................................................................................... 3 Table of Model Identification ............................................................................. 3 Customer Service.................................................................................. 4 Contents Wiring Diagram.................................................................................... 4 Nameplate Location........................................................
Inhaltszusammenfassung zur Seite Nr. 5
Introduction Model Identification Information in this manual is applicable to these models: † Gas Steam Electric/Other DT0220SFG DT0220SRG DT0220SSH DT0220SSL DT0220SEL DC0220SEL JT0220SFG JT0220SRG JT0220SSH JT0220SSL JT0220SEL JC0220SEL ST0220SFG ST0220SRG ST0220SSH ST0220SSL ST0220SEL SC0220SEL 25 Pound (220 Liter) DC0220SFG DC0220SRG DC0220SSL JC0220SSL JC0220SFG JC0220SRG SC0220SSL SC0220SFG SC0220SRG DT0300DFG DT0300DRG DT0300DSH DT0300DSL DT0300DEL DC0300DEL JT0300DFG JT0300DRG JT0300DS
Inhaltszusammenfassung zur Seite Nr. 6
Introduction Information in this manual is applicable to these models: † Gas Steam Electric/Other ATB50CG DTB50EG STB50CSH STB50CSL STB50CE JCB50CE STB50CG JTB50EG JTB50CSH JTB50CSL JTB50CE SCB50CE DTB50CG JT50EG DTB50CSH DTB50CSL DTB50CE JC50CE JTB50CG JC50EG JT50CSH JT50CSL JT50CE DCB50CE JT50CG JCB50EG JCB50CSH SCB50CSH SC50CE SCB50AT 50 Pound JC50CG SC50EG JC50CSH DCB50CSH JCB50CG SCB50EG ATB50CSH SC50CG DCB50CG SCB50CG DCB50EG STB50EG STB75CG DTB75EG STB75CSH JTB75CSL STB75CE JCB75CE DTB7
Inhaltszusammenfassung zur Seite Nr. 7
Introduction Nameplate Location When calling or writing for information about your product, be sure to mention model and serial numbers. Model and serial numbers are located on the nameplate as shown. The model number may also be found inside the door. ANS 72152 CLOTHES DRYER. VOL II MODEL NO: TESTED FOR NATURAL & SERIAL NO: LIQUID PETROLEUM GASSES V-/ HERTZ/ PHASE CGA 72 AMPS, WIRES + GROUND TOTAL kW, MOTOR kW AMPLFIEDRER REQ'D CIRCUIT BREAKER: AMPS FAN OUTPU
Inhaltszusammenfassung zur Seite Nr. 8
Notes © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT M414462 6
Inhaltszusammenfassung zur Seite Nr. 9
Safety Information Precautionary statements (“CAUTION,” NOTE: The word “NOTE” is used to communicate “WARNING,” and “DANGER”), followed by specific installation, operation, maintenance or servicing instructions, are found in this manual and on machine information that is important but not hazard decals. These precautions are intended for the personal related. safety of the operator, user, servicer, and those IMPORTANT: Warranty is void unless drying maintaining the machine. tumbler is insta
Inhaltszusammenfassung zur Seite Nr. 10
Safety Information 14. The interior of the tumbler and the exhaust duct Important Safety Instructions should be cleaned periodically by qualified service personnel. WARNING 15. If not installed, operated and maintained in accordance with the manufacturer’s instructions To reduce the risk of fire, electric shock, or if there is damage to or mishandling of this serious injury or death to persons when product’s components, use of this product could using your tumbler, follow these basic ex
Inhaltszusammenfassung zur Seite Nr. 11
Safety Information 23. Remove laundry immediately after tumbler stops. 28. DO NOT operate the tumbler with missing or broken parts. 24. Always read and follow manufacturer’s instructions on packages of laundry and cleaning 29. DO NOT by-pass any safety devices. aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep WARNING them out of reach of children at all times (preferably in a locked cabinet). To reduce the risk of serious injury, install 25. D
Inhaltszusammenfassung zur Seite Nr. 12
Notes © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT M414462 10
Inhaltszusammenfassung zur Seite Nr. 13
Operating Instructions WARNING To reduce the risk of fire: DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials. DO NOT DRY plastics, anything containing wax or chemicals such as mops and cleaning cloths, or anything dry-cleaned at home with a dry-cleaning solvent. DO NOT TUMBLE fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass. W076 To redu
Inhaltszusammenfassung zur Seite Nr. 14
Operating Instructions 1 2 0 0 60 10 15 50 HIGH LOW COOLING DRYING COTTON PERM 5 20 PRESS COOL 50 HEAT DOWN 40 10 30 10 MEDIUM 15 40 60 MIXED TEMPERATURE 0 0 30 HIGH LOW 10 5 20 PUSH TO START PUSH TO START 4 3 TMB47N TMB48N 50/75 POUND TUMBLERS 25, 30 AND 35 POUND TUMBLERS LOAD LOW AIR COOLING DRYING PUSH READY FLOW TO 50 START 10 15 40 60 HIGH LOW 0 0 190 130 30 NON REV 10 MEDIUM REV 160 5 20 TEMPERATURE TMB49N 120 AND 170 POUND TUMBLERS Figure 2 Manual Timer Tumblers WARNING 1. Set the TEMPER
Inhaltszusammenfassung zur Seite Nr. 15
Q U A R T E Operating Instructions SINGLE AND DUAL COIN TEMPERATURE SELECTOR METER COIN SLOT AND KNOB TEMPERATURE HIGH LOW INSERT QUARTER TURN KNOB 25 R PUSH TO START 1 2 3 SELECT INSERT PUSH TEMP COIN START PUSH TO START BUTTON T366I Figure 3 Electro-Mechanical Coin Control Tumbler WARNING 1. Set the TEMPERATURE selector at HIGH or LOW, or anywhere between these settings. To reduce the risk of bodily injury, the 2. Coin Drop Models: Insert the coin(s) in the coin tumbler stops tumbling w
Inhaltszusammenfassung zur Seite Nr. 16
Operating Instructions C851I C851I Figure 4 NetMaster Coin Control WARNING 1. Select HIGH TEMP, MED TEMP, LOW TEMP, or NO HEAT by pressing the appropriate To reduce the risk of bodily injury, the temperature pad. tumbler stops tumbling when the door is 2. Insert the coin(s) in the coin slot. opened. Do not use the tumbler if it does not stop tumbling when the door is opened 3. Press START pad to start tumbler. or starts tumbling without pressing the To stop the tumbler at any time duri
Inhaltszusammenfassung zur Seite Nr. 17
Operating Instructions C852I Figure 5 NetMaster Card Control WARNING 1. Select HIGH TEMP, MED TEMP, LOW TEMP, or NO HEAT by pressing the appropriate To reduce the risk of bodily injury, the temperature pad. tumbler stops tumbling when the door is 2. Insert card into opening. DO NOT remove the opened. Do not use the tumbler if it does card until “REMOVE CARD” LED is lit. not stop tumbling when the door is opened or starts tumbling without pressing the 3. Press START pad to start tumble
Inhaltszusammenfassung zur Seite Nr. 18
Operating Instructions ON / SELECT PROGRAM STATUS HIGH AUTO TIME DRYING START AUTO SPECIAL SPECIAL MEDIUM COOL DOWN STOP/RESET CYCLE TIME AUTO * * COOL MED LOW TEMP TEMP DOOR OPEN DOWN DISPLAY F/ C LOW SIGNAL CUSTOM MORE LESS +- - SAVE NO HEAT CONDITION REVERSING CUSTOM PROG T359I T359I Figure 6 Electronic OPL Control 2. Press START pad to start tumbler. 1. To use an Automatic Cycle, press an ON/ NOTE: All pads can be pressed in any sequence SELECT pad. Select HIGH, MEDIUM, without damaging
Inhaltszusammenfassung zur Seite Nr. 19
Operating Instructions 1 2 3 SELECT INSERT PUSH TEMP COIN START C 25 HIGH LOW TEMP TEMP START MED NO TEMP HEAT T361I T361I Figure 8 Electronic Coin Control WARNING 1. Select HIGH TEMP, MED TEMP, LOW TEMP, or NO HEAT by pressing the appropriate To reduce the risk of bodily injury, the temperature pad. tumbler stops tumbling when the door is 2. Insert the coin(s) in the coin slot. opened. Do not use the tumbler if it does not stop tumbling when the door is opened 3. Press START pad to sta
Inhaltszusammenfassung zur Seite Nr. 20
Operating Instructions IMPORTANT: After any electrical maintenance is Reversing Operation done, make sure that the blower motor is turning Tumblers with the reversing options are equipped with clockwise as viewed from the front of the 0350S, 50, a second motor and additional controls to reverse the and 75 pound tumblers and counterclockwise on direction of the cylinder rotation. This prevents the the 634, 120 and 170 pound tumblers. Then set the tangling of large pieces and minimizes wri