Inhaltszusammenfassung zur Seite Nr. 1
Installation Instructions
Part No. 8527809
IMPORTANT:
Read and save COMMERCIAL
these instructions DRYER
IMPORTANT
GAS ELECTRIC
Installer: Leave Installation Instructions
with the owner.
120-volt, 60 Hz 120/240-volt, 60 Hz
Owner: Keep Installation Instructions for
future reference.
Save Installation Instructions for local
®
electrical inspector’s use.
COMMERCIAL
www.whirlpool.com
LAUNDRY
PRODUCTS
Inhaltszusammenfassung zur Seite Nr. 2
IMPORTANT SAFETY INSTRUCTIONS Before you start... WARNING — To reduce the risk of fire, electric shock, or injury to persons when Your safety and the safety of others are very important. using your appliance, follow basic precautions, including the following: We have provided many important safety message in this manual and DANGER 1. Read all instructions before using the appliance. on your appliance. Always read You can be killed or seriously and obey all safety messages. 2. Do not dry articles
Inhaltszusammenfassung zur Seite Nr. 3
exhaust airflow The console houses the electronic For exhaust systems not covered by control board. The board is factory the exhaust length chart, see better good set for a dry time of 45 minutes. exhaust exhaust Whirlpool Service Manual, “Exhausting airflow airflow Consult the tech sheet found inside Whirlpool Dryers,” Part No. 603197, the dryer toe panel to reset dry time available from your Whirlpool parts and for other options. distributor. The coin-slide mechanism, control If dryer is insta
Inhaltszusammenfassung zur Seite Nr. 4
dryer exhaust vent dryer exhaust vent An exhaust hood should cap the An exhaust hood should cap the outside end of the main vent to exhaust vent to prevent exhausted air Gas Dryer prevent exhausted air from returning from returning into the dryer. The to the dryers. If an exhaust hood outlet of the hood must be at least cannot be used, the outside end of Gas requirements 12 inches (30.5 cm) from the ground the main vent should have a sweep or anything else that may be in the elbow directed down
Inhaltszusammenfassung zur Seite Nr. 5
A 120-volt, 60-Hz, AC-only, 15- or C. Check that dryer is equipped H. If local codes and ordinances 20-ampere fused electrical supply is with the correct burner for the permit, it is recommended that new required. A time-delay fuse or circuit particular type of gas used. Burner flexible metal tubing, design-certified breaker is recommended. information can be found on the by the AGA or CSA, be used for It is recommended that a separate serial/rating plate in the door well of connecting the dry
Inhaltszusammenfassung zur Seite Nr. 6
Now Start... 5. Remove the service door of the 11. To exhaust dryer, see Exhaust meter case. Lift requirements, Pages 3-4. Connect With dryer in laundry area. the service door exhaust vent system to dryer exhaust up at the back outlet and exhaust hood using 4" and remove. (10.2 cm) clamps. Use caulking to WARNING Install money- seal exterior wall opening around accepting exhaust hood. Excessive Weight Hazard device. (Refer to Use two or more people to move manufaturer's 12. Carefully move dryer
Inhaltszusammenfassung zur Seite Nr. 7
Now Start... Electric Dryer 5. Remove the service door of the Electrical meter case. Lift WARNING the service door requirements Excessive Weight Hazard up at the back Use two or more people to move and and remove. If codes permit and a separate Install money- install dryer. ground wire is used, it is accepting recommended that a qualified Failure to do so can result in back or device. (Refer to electrician determine that the ground other injury. manufaturer's path is adequate. instructions for
Inhaltszusammenfassung zur Seite Nr. 8
WARNING - Improper connection of Direct wire (U.S. only) 7.U.S. installations: the equipment-grounding conductor Make electrical connection. can result in a risk of electric shock. Check with a qualified electrician or This dryer is manufactured with the WARNING service representative or personnel if cabinet-ground conductor you are in doubt as to whether the connected to the NEUTRAL (center) of appliance is properly grounded. Do the wiring harness at the terminal not modify the plug provided w
Inhaltszusammenfassung zur Seite Nr. 9
Four-wire connection... Four-wire receptacle (required for mobile homes) POWER SUPPLY CORD 4. Remove center terminal block screw. 5. Remove appliance ground wire spade (green with yellow stripes) from terminals with external ground connector screw. upturned ends Fasten under center, silver-colored terminal block screw. 6. Connect neutral wire (white or 3/4" U.L.-listed NEUTRAL (white) center) of power supply cord under NEUTRAL strain relief center screw of the terminal block. Tighten screw. 7.
Inhaltszusammenfassung zur Seite Nr. 10
Three-wire connection... Three-wire receptacle POWER SUPPLY CORD 4. Loosen or remove center spade terminal block screw. terminals with upturned ends 5. Connect the neutral wire (white or center) of power supply cord to ring the center, silver-colored terminal terminals screw of the terminal block. This blade connected Tighten screw. to this conductor. 6. Connect the other wires to outer terminal block screws. Tighten screws. NEUTRAL 3/4" U.L.-listed NEUTRAL strain relief (white or center) 7. T
Inhaltszusammenfassung zur Seite Nr. 11
Three-wire connection... Three-wire receptacle DIRECT WIRE OR Where local codes Do Not permit connecting cabinet-ground conductor to neutral wire: POWER SUPPLY CORD 4. Remove center terminal block screw. Three-wire power supply cord must have three, No.-10 copper wires and 5. Remove the appliance harness match a three-wire receptacle of NEMA ground wire (green with yellow Type 10-30R. stripes) from the external ground connector screw. Connect appliance harness ground wire and Direct wire power
Inhaltszusammenfassung zur Seite Nr. 12
Recessed area and Maintenance If dryer does not closet installation instructions operate properly... • Clean lint screen after each cycle. instructions Check the following to be sure that: • Keep dryer area clear and free from 1. Electric supply is connected. This dryer may be installed in a combustible materials, gasoline and recessed area or closet. For recessed 2. Circuit breakers are not tripped or other flammable vapors and liquids. area and closet installations, house fuses blown. • Do not
Inhaltszusammenfassung zur Seite Nr. 13
Product dimensions 29" (73.7 cm) dryer 25-1/2" (64.8 cm) 29" (73.7 cm) non-coin-operated models: 7-1/8" (18.1 cm) ELECTRIC 35" coin-operated (88.9 cm) 16" models: (40.6 cm) 7-7/8" (20 cm) 27-1/4" (69.2 cm) 4-3/4" 4" (10.2 cm) 13" (12.1 cm) dia. (33 cm) 1-1/4" (3.2 cm) GAS EXHAUST 18-3/8" 1" (46.7 cm) (2.5 cm) BACK VIEW SIDE VIEW 27" (68.6 cm) dryer 29-1/4" (74.3 cm) 27" (68.6 cm) 26-1/2" (64.8 cm) non-coin- ELECTRIC 14" operated models: (35.6 cm) 7-1/8" (18.1 cm) 37" coin-operated (94 cm) mo
Inhaltszusammenfassung zur Seite Nr. 14
Instructions d’installation Pièce n° 8527809 IMPORTANT : Lire et conserver SÉCHEUSE ces instructions. COMMERCIALE IMPORTANT GAZ ÉLECTRIQUE Installateur : Remettre les instructions d’installation au propriétaire. 120 volts, 60 Hz 120/240 volts, 60 Hz Propriétaire : Conserver les instructions d’installation pour consultation ultérieure. Conserver les instructions d’installation pour consultation par l’inspecteur local des ® installations électriques. APPAREILS DE www.whirlpool.com BUANDERIE COMM
Inhaltszusammenfassung zur Seite Nr. 15
Avant de commencer... IMPORTANTES INSTRUCTIONS DE SÉCURITÉ Votre sécurité et celle des autres est très importante. AVERTISSEMENT – Pour réduire le risque d’incendie, de choc électrique ou de Nous donnons de nombreux blessure lors de l’utilisation de l’appareil, DANGER messages de sécurité importants il convient d’observer certaines dans ce manuel et sur votre Risque possible de décès ou de précautions élémentaires dont les appareil ménager. Assurez-vous de blessure grave si vous ne suivez suivan
Inhaltszusammenfassung zur Seite Nr. 16
L’orifice d’évacuation de la sécheuse CONSERVEZ CES INSTRUCTIONS de la sécheuse, en bas/au centre. doit être relié à l’extérieur. On peut acheminer le conduit Ne pas évacuer l’air de la sécheuse Afficher cet avertissement en un d’évacuation par le haut, par le bas, par dans une cheminée, le conduit endroit très visible. la gauche, par la droite, ou en ligne d’évacuation d’un appareil à gaz, droite depuis l’arrière de la sécheuse. POUR VOTRE SÉCURITÉ dans un grenier ou vide sanitaire ou La longu
Inhaltszusammenfassung zur Seite Nr. 17
conduit d’évacuation de sécheuse conduit d’évacuation de sécheuse L’extrémité du conduit d’évacuation Faire en sorte que les vapeurs générées devrait être dotée d’une bouche de par les liquides de nettoyage à sec ne Sécheuse à gaz décharge empêchant l’air évacué de puissent pas atteindre les orifices d’entrée revenir à la sécheuse. L’orifice de la d’air; ces vapeurs créent des composés bouche de décharge doit être situé à au acides qui, lorsqu’ils sont attirés vers les Spécifications moins 30,5
Inhaltszusammenfassung zur Seite Nr. 18
Important : Respecter les prescriptions de C. Vérifier que la sécheuse est équipée H. Si les codes et règlements locaux le tous les codes et règlements en vigueur. du brûleur convenable, correspondant au permettent, on recommande l’emploi d’un L’appareil doit être alimenté par un circuit gaz spécifique qui alimente l’habitation. conduit métallique flexible neuf de électrique de 120 V (CA seulement), 60-Hz, L’information sur le brûleur se trouve sur la conception homologuée par l’American protégé
Inhaltszusammenfassung zur Seite Nr. 19
Commencer... 5. Ôter la plaque de l’ouverture 11. Consulter les pages 3-4 pour les d’accès du boîtier instructions concernant le circuit Avec la sécheuse dans la buanderie. de commande. d’évacuation de la sécheuse. Connecter Soulever la plaque le conduit d’évacuation à l’orifice de à l’arrière pour sortie de la sécheuse et à la bouche de AVERTISSEMENT l’enlever. Installer décharge à l’extérieur à l’aide de brides le dispositif de 10,2 cm (4 po). Calfeutrer à l’extérieur Risque du poids excessif
Inhaltszusammenfassung zur Seite Nr. 20
Commencer... Sécheuse électrique 5. Ôter la plaque de l’ouverture d’accès du boîtier de commande. Soulever la plaque à l’arrière pour Spécifications de AVERTISSEMENT l’enlever. Installer l’installation électrique le dispositif Risque du poids excessif d’introduction de Utiliser deux ou plus de personnes Si on utilise un conducteur distinct de pièces (pour pour déplacer et installer la sécheuse. liaison à la terre lorsque le code local le l’installation, Le non-respect de cette instruction permet