Inhaltszusammenfassung zur Seite Nr. 1
INSTALLATION
NOTE: A wiring diagram is located inside the dryer.
1. GAS CONNECTION (Gas dryers only)
REPLACEMENT PARTS
a. Remove the shipping cap from gas pipe at the rear of
the dryer.
NOTE: DO NOT connect the dryer to L.P. gas service without If replacement parts are needed for your dryer, contact the
converting the gas valve. An L.P. conversion kit must source where you purchased your dryer, or call Sears Parts
be installed by a qualified gas technician. and Service Toll Free Number 1-800-4-M
Inhaltszusammenfassung zur Seite Nr. 2
GREEN POWER CORD GREEN GREEN GROUND WIRE GROUND SILVER TERMINAL GROUND SCREW SILVER TERMINAL SCREW TERMINAL BLOCK GREEN NEUTRAL GROUND WIRE GREEN TIGHTEN BLACK NEUTRAL NUT GROUND TO THESE WHITE NUT WIRE THREADS TIGHTEN NUT NUT TO THESE RED STRAIN THREADS RELIEF MOUNTING BRACKET POWER CORD STRAIN RELIEF ELECTRICAL CONNECTIONS MOUNTING BRACKET POWER CORD FOR 4-WIRE SYSTEM ELECTRIC Dryer 1. Remove the screws securing the terminal block access ELECTRICAL CONNECTIONS cover and the strain relief moun
Inhaltszusammenfassung zur Seite Nr. 3
ELECTRICAL INSTALLATION For a permanently connected dryer: 1. The dryer MUST be connected to a grounded metal, Before proceeding with electrical installation, install the permanent wiring system; or an equipment grounding con- dryer's coin-metering system (when used) in accordance ductor must be run with the circuit conductors and with the separate instructions provided with the meter. connected to the equipment-grounding terminal or lead on the appliance. ALL ELECTRIC Dryers The following are
Inhaltszusammenfassung zur Seite Nr. 4
UNPACKING ROUGH-IN DIMENSIONS 1. Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove foam shipping base. To prevent damage, do not use the control panel or coin meter housing as a means to (68.3 cm) 43/8 pick up or move the dryer. > < (11.2) NOTE: On under counter model clothes dryers, the top panel may be removed for installation. ELECTRIC CONNECTION 2. Return the dryer to an upright position. (6.5 cm) FOAM 13 1/2" SHIPPING (34.4
Inhaltszusammenfassung zur Seite Nr. 5
LOCATION OF YOUR DRYER 4. A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when DO NOT INSTALL YOUR DRYER: a door is installed. A louvered door with equivalent air 1. In an area exposed to dripping water or outside weather openings for the full length of the door is acceptable. conditions. MINIMUM INSTALLATION CLEARANCES (Inches) 2. In an area where it will come in contact wit
Inhaltszusammenfassung zur Seite Nr. 6
Venting vertical through a roof may expose the ex MAXIMUM LENGTH haust system to down drafts causing an increase in of 4” (10.2 cm) Dia. Rigid Metal Duct vent restriction. Running the exhaust system through an uninsulat- VENT HOOD TYPE ed area may cause condensation and faster accumu (Preferred) lation of lint. Compression or crimping of the exhaust system will Number Louvered of cause an increase in vent restriction. 90° 4” 2½" Turns The exhaust system should be inspected and cleaned a
Inhaltszusammenfassung zur Seite Nr. 7
POWER SUPPLY CORD - The dryer is equipped with a 120 PRE-INSTALLATION REQUIREMENTS volt 3-wire power cord. Tools and Materials Required for Installation: 1. Phillips head screwdriver. NOTE: Do not under any circumstances 2. Channel-lock adjustable pliers. remove grounding 3. Carpenter's level. prong from plug. 4. Flat or straight blade screwdriver. 5. Duct tape. 6. Rigid or flexible metal 4 inch (10.2 cm) duct. GROUNDING PRONG 7. Vent hood. 8. Pipe thread sealer (Gas). EXHAUST SYSTEM REQ
Inhaltszusammenfassung zur Seite Nr. 8
Installation Instructions Gas & Electric Dryer Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future reference. NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70. NOTE: The gas service to the Dryer must conform with loca
Inhaltszusammenfassung zur Seite Nr. 9
Inhaltszusammenfassung zur Seite Nr. 10
REPAIR PARTS LIST 417.74182300 Dryer When placing a part order, give the complete model number shown on the serial plate located on the inside of the dryer door. All repair parts listed are available for immediate purchase or special order when you visit your nearest Sears Service Cen- ter. To order parts by phone, call the toll free parts number To Call Toll Free listed to the left. For Parts: 1-800-366-PART When requesting service or ordering parts, always provide the following information: (1
Inhaltszusammenfassung zur Seite Nr. 11
417.74182300 CABINET/DRUM CAUTION: Use the Kenmore part number to order parts, not the illustration number. 10/03 2
Inhaltszusammenfassung zur Seite Nr. 12
417.74182300 CABINET/DRUM CAUTION: Use the Kenmore part number to order parts, not the illustration number. POS. NO PART NO DESCRIPTION 2 131962400 Screw,tamper resist ,10-16 x .375 5 5303281019 Ball 6 5303281020 Clip,ball ,steel ,flat nut 9 131793201 Panel,access ,rear 11 131363200 Cover,terminal block 12 131825900 Bearing,drum support 13 131724300 Bracket,bearing support 14 131205400 Screw,bracket mtg. ,10-16B x 1.375 ,cr/sq drive 15 # 131600500 Housing,gas heater assy ,w/seal 18 131477000 Scr
Inhaltszusammenfassung zur Seite Nr. 13
417.74182300 FRONT PANEL/LINT FILTER CAUTION: Use the Kenmore part number to order parts, not the illustration number. 10/03 4
Inhaltszusammenfassung zur Seite Nr. 14
417.74182300 FRONT PANEL/LINT FILTER CAUTION: Use the Kenmore part number to order parts, not the illustration number. POS. NO PART NO DESCRIPTION 1 134063300 Seal,air duct 2 131397000 Plug,dome ,white 6 131621902 Duct,air 8 131622202 Cover,lint housing 9 134146500 Plug,hinge hole ,white 16 131063700 Clip,wiring 20 134036400 Seal,felt ,upper 20* 5308027429 Adhesive,high temp 21 134134700 Seal,felt ,lower 22 131845902 Panel,front ,white ,with lamp hole 22* 131870700 Plug,light hole 22* 131474700
Inhaltszusammenfassung zur Seite Nr. 15
417.74182300 CONTROLS/TOP PANEL CAUTION: Use the Kenmore part number to order parts, not the illustration number. 47 57 58 59 48 53 61 61 23 15 10 65 17 29 4 24 66 7 P16C0217 10/03 6
Inhaltszusammenfassung zur Seite Nr. 16
417.74182300 CONTROLS/TOP PANEL CAUTION: Use the Kenmore part number to order parts, not the illustration number. POS. NO PART NO DESCRIPTION 4 131689300 Knob,rotary ,white & gray 7 3205821 Clip,top-to-front 10 # 131469000 Switch,push/start 15 # 131288900 Switch,temperature 17 134064501 Bracket,control mtg. 23 134028500 Wiring Harness,controls * # 134310200 Wiring Harness,main 24 131970200 Button,push/start ,white 29 131666969 Console,frame ,w/trim & tape 47 # 134274001 Meter Case,assy 47* 5304
Inhaltszusammenfassung zur Seite Nr. 17
417.74182300 MOTOR CAUTION: Use the Kenmore part number to order parts, not the illustration number. 34 47 7 23 10 52 51 22 27 11 4 52 15 34 20 28 48 25 46 P16M0027 10/03 8
Inhaltszusammenfassung zur Seite Nr. 18
417.74182300 MOTOR CAUTION: Use the Kenmore part number to order parts, not the illustration number. POS. NO PART NO DESCRIPTION 4 131435200 Lock,blower housing 7 131451600 Tube,exhaust ,rear ,w/mtg bracket 7* 131456800 Tube,exhaust ,side/bottom ,Optional Kit 10 # 131775600 Housing,blower assy ,cover & wheel 11 131749800 Spacer,idler 15 # 131298400 Thermostat,temp control 20 131017900 Screw,hex head ,1/4-20T x 1.25 ,spacer mtg.,thread cutting 22 131601000 Spring,idler arm 23 131863002 Idler Arm
Inhaltszusammenfassung zur Seite Nr. 19
417.74182300 BURNER CAUTION: Use the Kenmore part number to order parts, not the illustration number. 10/03 10
Inhaltszusammenfassung zur Seite Nr. 20
417.74182300 BURNER CAUTION: Use the Kenmore part number to order parts, not the illustration number. POS. NO PART NO DESCRIPTION 2 131168200 Screw,pan head ,8-18B x 0.31 34 131243700 Screw,pan head ,8-18AB x 0.375 ,cr/sq drive 55 # 134264700 Wiring Harness,gas valve 61 134122000 Bracket,burner mtg 64 134144900 Pipe,gas ,right angle 65 08015112 Cap,pipe 66 134128700 Bushing,coupler 68 134185100 Tail Piece,coupling 69 # 5308015194 Union,hex nut 70 # 5303207409 Valve,gas 71 # 5303307291 Coil,secon