Inhaltszusammenfassung zur Seite Nr. 1
INSTALLATION INSTRUCTIONS
HB0058
WP29M SERIES
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE, CARE AND OPERATION INFORMATION
ON PAGES 10 AND 11.
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
REGISTER YOUR PRODUCT ON LINE AT: www.BestRangeHoods.com/register
For additional information - visit www.BestRangeHoods.com
SV07693
Inhaltszusammenfassung zur Seite Nr. 2
! ! WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC TO REDUCE THE RISK OF INJURY TO PERSONS SHOCK OR INJURY TO PERSONS, OBSERVE IN THE EVENT OF A RANGE TOP GREASE THE FOLLOWING: FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the 1. SMOTHER FLAMES with a close-fitting lid, cookie manufacturer. If you have questions, contact the sheet or metal tray, then turn off the burner. manufacturer at the address or telephone number BE CAREFUL TO PREVENT BURNS. IF THE
Inhaltszusammenfassung zur Seite Nr. 3
- WP29M SERIES RANGE HOOD SYSTEM - INTERIOR BLOWERS Model 647 Model 634 or 644 Model 437 Model 441 (High capacity roof cap) (10’’ Round wall cap) (7” Round wall cap) (roof cap) Model 418 Model 415 (10” round adjustable elbow) (7” round adjustable elbow) Model 421 (10” Round Vertical In-line damper — Optional) Model 407 (7” round duct—2 ft. sections) Model 410 (10” round duct—2 ft. sections) Model 427 Model 423 Model 424 Model 454 Model 453 (4½” x 18½” (4½” x 18½” (4½” x 18½” (4½” x 18½” (4½”
Inhaltszusammenfassung zur Seite Nr. 4
- WP29M SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLOWERS Model 441 Model 437 Model ILB9 (800 cfm) (10” Round wall cap) (High capacity roof cap) Model EB12 (1200 cfm) or ILB11 (1100 cfm) or EB15 (1500 cfm) in-line blower exterior blower Model EB6 (600 cfm) (includes two 8” x 12” to or EB9(900 cfm) 10’’ round transitions) exterior blower Model 441 (10” Round Model 643 wall cap) (8” Round wall cap) Model ILB6 (600 cfm) in-line blower (includes two 4½” x 18½” to 10’’ round transitions) Mode
Inhaltszusammenfassung zur Seite Nr. 5
1. SELECT BLOWER OPTION AND INSTALLATION TYPE 1.1 NON-DUCTED INSTALLATION For a non-ducted installation, we recommend using interior blower Best model P6 for effectiveness. (Blower sold separately.) The non-duct kit ANKWP Series (sold separately) must be installed. This kit fits hood from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKWP Series. 1.2 DUCTED INSTALLATION For a ducted installation, either an interior or exterior blower or in-line
Inhaltszusammenfassung zur Seite Nr. 6
2. MEASURE INSTALLATION Dimensions for the most common installation are shown beside. Ceiling The minimum hood distance above cooktop must not be less Cabinet, soffit, than 24’’. A maximum of 30” above cooktop is highly Top of wood decorative flue or A recommended for best capture of cooking impurities. mounting strip non-duct kit flue A + 0.25’’ (6 mm) Distances over 30” are at the installer and users discretion. Hood Minimum distance between the hood and cooktop: 24’’ (610 mm) Recommended m
Inhaltszusammenfassung zur Seite Nr. 7
4. REMOVE THE FILTERS AND THE GREASE DRIP RAIL(S) 1 A. Remove tape on filters. Remove filters from hood and set aside. NOTE: It is recommended to start with the central one. B. Remove tape on grease drip rail (1). Lift out grease drip rail and set aside. NOTE: The 60-inch width hood has 2 grease drip rails. HD0175 5. REMOVE THE PAN Using a Phillips no. 2 or Robertson no. 2 screwdriver, remove the screws retaining the pan (shaded part on illustration beside) to the hood. Remove the pan and set
Inhaltszusammenfassung zur Seite Nr. 8
8. INSTALL THE HOOD Rest the top back cavity of the hood on the wood mounting strip. CAUTION Hold the hood until it is completely secured to the wood mounting TOP OF HOOD (INSIDE VIEW) strip. MOUNTING SCREWS LOCATION Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4” (for 30” and 36” width hoods) or (6) screws (for 42” width and wider hoods) provided at locations shown. Drill (2) 3/16’’ size holes into the drywall for wall anchors through the BACK OF HOOD (INSIDE VIEW) existing
Inhaltszusammenfassung zur Seite Nr. 9
13.INSTALL THE BLOWER (INTERIOR OR EXTERIOR BLOWER) Refer to instructions included with blower. Once the blower is installed, plug the blower cord (A) into the female receptacle and the power supply cord (B) onto the male connector inside the hood. AB ! WARNING Do not plug the two cords into each other. HE0078 14.REINSTALL THE PAN Using a Phillips no. 2 or Robertson no. 2 screwdriver and the retaining screws, reinstall the pan (previously removed in step 6) inside the hood (shaded part on illust
Inhaltszusammenfassung zur Seite Nr. 10
16.LIGHT BULBS REPLACEMENT WARNING ! In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures. This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included). ! WARNING In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing them. 12 3 1. To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.
Inhaltszusammenfassung zur Seite Nr. 11
18.OPERATION Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter. 2 1 3 4 HC0030 1. ON/OFF Blower switch 3. ON/OFF Halogen light switch 2. Blower speed control 4. Light intensity control Blower The blower is operated using two (2) controls. Use the ON/OFF switch (item 1 on picture above) to start and stop th
Inhaltszusammenfassung zur Seite Nr. 12
SERVICE PARTS 7 4 8 1 3 5 6 2 11 12 10 9 14 13 HL0083 WP29XX4 MODEL KEY PART QTY. (HOOD WIDTH) NO. NUMBER DESCRIPTION 30’’ 36’’ 42’’ 48’’ 54’’ 60’’ 1 SV16569 LAMP SHELL, SOCKET AND TRIM ASS’Y 44 46 66 2 SV05921 SHIELDED HALOGEN BULBS (50 W, 120 V, PAR16, GU-10) 4 4 4 6 6 6 3 SV03501 ROTARY CONTROL 22 22 22 4 SV07689TOGGLE SWITCH 22 22 22 5 SV16966 PLASTIC CONTROL FRAME AND KNOB ASS’Y 11 11 11 6 SV07688 KNOB 22 22 22 7 SV13924 MALE CONNECTOR 11 11 11 8 SV13923 FEMALE CONNECTOR 11 11 11 SV16793 GR