KV - 2000 Series
User’s Manual
Rev. Original
FCC Notes:
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions manual, may cause interference to radio
communications. It has been tested and found to comply with
limits for a Class A digital device pursuant to subpart J of
Part 15 of FCC Rules, which are designed to provide reasonable protection
Inhaltszusammenfassung zur Seite Nr. 2
ALERT TO OUR HONORABLE CUSTOMERS: Please always read thoroughly all the instructions and documents delivered with the product before you do anything about it. Don’t take any premature action before you have a full understanding of the consequences. This product contains inside a Lithium battery. Please always follow local environmental protection laws / regulations for disposal of used batteries and always replace only with battery of same type. DAILY MAINTENANCE GUIDE For regular c
Inhaltszusammenfassung zur Seite Nr. 3
memory card or HDD. THE STANDARD FEATURES CPU: AMD LX700; HDD: option; RAM: 128 MB upgradeable to 1 GB. Ethernet Networking: The standard network port works with both 10 Base T and 100 Base T. Serial Ports: There are 2 serial ports in a KV-2000 system. Each COM port is capable of providing independently a +5 V DC. All these DC supplies are achieved through internal jumper setting and they are all defaulted to give no DC supply at delivery. Parallel Port: Each KV system is equipped wit
Inhaltszusammenfassung zur Seite Nr. 4
INSTALLATION GUIDES IMPORTANT Please do not connect the power cord or turn on the main unit until you have fully read the installation guides and followed the instructions!!! TECHNICAL ENHANCEMENTS Applicable technical enhancements in KV-2000 series include serial COM port power supply settings, RTC battery replacement, VGA port power supply setting, DRAM upgrades. All these technical enhancement operations require consultation from Posiflex authorized dealers and should be handled on
Inhaltszusammenfassung zur Seite Nr. 5
ANNEX: WALL MOUNT APPLICATION The wall mount option kit contains 2 pcs of plastic cotters, 2 pcs of self-tapping screws and 1 pc of metal wall mount bracket as drawn in template below. Select a flat surface on wall of adequate strength and with proper ventilation and space condition. Apply the below printed drilling template on the wall surface. Drill 2 holes in horizontal layout as marked as dashed crosses in the template that is 5.3” or 135 mm wide (center to center). Hole diameter shou
Inhaltszusammenfassung zur Seite Nr. 6
Ant. LAN LPT 1 Mouse COM 2 MIC. USB 1 USB 3 Line out DC12V KB USB 0 USB 2 VGA COM 1 GND ANNEX
Inhaltszusammenfassung zur Seite Nr. 7
AUDIO PORT The audio output port must be connected either the earphone or a pair of speakers with booster or amplifier if used. CF MEMORY CARD (OPTION) When there is an optional CF memory card delivered with the KV system, there will be no HDD installed in the system. These 2 devices conflict to each other on system resources configuration and must not exist in a system in the same time. The optional CF memory card should be inserted into the CF slot in front of the system after protec
Inhaltszusammenfassung zur Seite Nr. 8
operation. The power supply cable should first be connected to the power inlet (but NOT the wall socket). OPERATING SYSTEM RECOVERY When the operating system in the optional CF card collapses, the most convenient way is to purchase from your system integrator a separately prepared functional new CF card for replacement. Once the software system on HDD collapses, it is possible to restore the operating system onto a physically intact HDD with use of the Recovery CD that comes with the
Inhaltszusammenfassung zur Seite Nr. 9
USING THE KV SYSTEM BEFORE POWER ON – A Check List It is very important that you check the following operational points: Ventilation This terminal must NOT be operated in an environment with restricted ventilation. There must be at least 25 mm air clearance around any top or side ventilation holes with a free flow of air around the unit at ALL times for the installation. Operating Environment The equipment must not site in direct sunshine, near a heater or in a damp and must be free
Inhaltszusammenfassung zur Seite Nr. 10
USB There are 4 standard USB type A female connectors in the connection area. All support the Universal Serial Bus Specification standard 2.0 and also 1.1 compatible. Part 8