Inhaltszusammenfassung zur Seite Nr. 1
4-122-512-13 (1)
LCD Monitor
Instructions for Use
Before operating the unit, please read this manual
thoroughly and retain it for future reference.
LMD-3250MD
© 2008 Sony Corporation
Inhaltszusammenfassung zur Seite Nr. 2
For the customers in the U.S.A and Canada Owner’s Record When you use this product connected to 240 V single The model and serial numbers are located at the rear. phase, be sure to connect this product to a center tapped Record these numbers in the spaces provided below. circuit. Refer to these numbers whenever you call upon your Sony dealer regarding this product. Important safeguards/notices for use in the medical environments Model No. ____________________ 1. All the equipments connected
Inhaltszusammenfassung zur Seite Nr. 3
Caution Symbols on the unit When you dispose of the unit or accessories, you must obey the law in the relative area or country and the Symbol Location This symbol indicates regulation in the relative hospital. Bottom Power switch. Press to turn the monitor For the customers in the USA on. Lamp in this product contains mercury. Disposal of these materials may be regulated due to environmental considerations. For disposal or recycling information, Bottom Power switch. please contact your loc
Inhaltszusammenfassung zur Seite Nr. 4
Important EMC notices for use in the medical environments • The LMD-3250MD needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this instructions for use. � The portable and mobile RF communications equipment such as cellular phones can affect the LMD-3250MD. Warning The use of accessories and cables other than those specified, with the exception of replacement parts sold by Sony Corporation, may result in incr
Inhaltszusammenfassung zur Seite Nr. 5
Guidance and manufacturer’s declaration - electromagnetic immunity The LMD-3250MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD- 3250MD should assure that it is used in such as environment. IEC 60601 test Immunity test Compliance level Electromagnetic environment - guidance level Electrostatic ±6 kV contact ±6 kV contact Floors should be wood, concrete or ceramic tile. If floors are discharge (ESD) covered with synthetic material, t
Inhaltszusammenfassung zur Seite Nr. 6
Guidance and manufacturer’s declaration - electromagnetic immunity The LMD-3250MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD- 3250MD should assure that it is used in such as environment. IEC 60601 test Immunity test Compliance level Electromagnetic environment - guidance level Portable and mobile RF communications equipment should be used no closer to any part of the LMD-3250MD, including cables, than the recommended separation
Inhaltszusammenfassung zur Seite Nr. 7
Recommended separation distances between portable and mobile RF communications equipment and the LMD- 3250MD The LMD-3250MD is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the LMD-3250MD can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (Transmitters) and the LMD-3250MD as recommended below, according to the maximum output po
Inhaltszusammenfassung zur Seite Nr. 8
Table of Contents Precaution ..............................................................9 On Safety ............................................................ 9 On Installation .................................................... 9 About the LCD Display Panel ............................ 9 About the Fluorescent Tube ............................... 9 On Cleaning ....................................................... 9 Disposal of the Unit ......................................... 10 Recomme
Inhaltszusammenfassung zur Seite Nr. 9
the monitor becomes warm, the screen returns to normal. Precaution � If a fixed picture such as a frame of a divided picture or time code, or a still picture is displayed for a long time, an image may remain on the screen and be On Safety superimposed as a ghosting image. � The screen and the cabinet become warm during � Operate the unit on 100-240 V AC only. operation. This is not a malfunction. � The nameplate indicating operating voltage, etc. is located on the AC adaptor. � Should any
Inhaltszusammenfassung zur Seite Nr. 10
Disposal of the Unit Features � Do not dispose of the unit with general waste. Do not include the monitor with household waste. � The fluorescent tube includes mercury. Dispose of the Compliance with medical safety monitor in accordance with the regulations of your standards in America, Canada and local sanitation authority. Europe UL60601-1 for America, CSA C22.2 No.601.1 for Canada and EN 60601-1 for Europe have been obtained Recommendation to Use more than for this monitor. One Unit Th
Inhaltszusammenfassung zur Seite Nr. 11
*1 Accepts DVI-D (digital) input signals Aspect setting Adopting the scan converter allows this monitor to You can set the monitor to 4:3 or 16:9 display mode detect VGA, SVGA, XGA and SXGA digital computer according to the input signal. signals input to the DVI input connector. Scan function To view SXGA signals when the DVI input is selected, 1 You can select the display from among “NORMAL”, use the cable within 3 m (118 /8 inches) in length. “OVER” and “NATIVE” (720P only) except the HD15
Inhaltszusammenfassung zur Seite Nr. 12
Location and Function of Parts and Controls Front Panel 1 2 3 COMPOSITE CONTROL 4 Y/C RGB + COMPONENT CONTRAST – 5 A-1 0 + PHASE A-2 – 6 B-1 + CHROMA B-2 – 7 HD15 + DVI BRIGHT – 8 F1 MENU F2 + qa F3 – 9 F4 ENTER USER MEM RETURN qs a Tally lamp Adjusts the color intensity. You can check the status of the monitor by the color of Press the + button to increase the color intensity or the – the tally lamp. button to decrease it. The tally lamp lights in green according to the setting of h BRIGHT (b
Inhaltszusammenfassung zur Seite Nr. 13
j Input select buttons Press the button to monitor the signal input to each connector. A-1, A-2, B-1 and B-2 buttons are used when an optional input adaptor has been installed in the option slot. COMPOSITE button: to monitor the signal through the COMPOSITE IN connector Y/C button: to monitor the signal through the Y/C IN connector RGB button: to monitor the RGB signal through the connectors for the R/G/B signal input COMPONENT button: to monitor the component signal through the connector
Inhaltszusammenfassung zur Seite Nr. 14
Input signals and adjustable/setting items Input signal 3 3 4 4 Item Video* , B & W* Component* RGB* SDI Computer 3 Y/C* 5 6 SD HD SD HD D1* HD* DVI HD15 1 CONTRAST* a a a a aaaa a a 1 BRIGHT* a a a a aaaa a a 1 CHROMA* a × a a aaaa a a 1 PHASE* a × a a aaaa a a (NTSC) APERTURE a a a a aaaa a a COLOR TEMP a a a a aaaa a a COLOR SPACE a a a a aaaa a a AUTO CHROMA/ a aa ×× × × × ×× PHASE ACC a × × ×××× × × × CTI a × a ×××× × × × V SHARPNESS aa a × a × a ×× × 2 MATRIX* × ×× a ××× × × × COMPONENT L
Inhaltszusammenfassung zur Seite Nr. 15
Side/Rear Panel qs qd qf qa DC +24V qg 5V24V IN +5V qh IN G/Y OUT 5 IN B/PB OUT 6 IN R/PR OUT 1 2 7 EXT IN OUT SYNC 3 8 Y/C IN OUT 9 COMPOSITE IN OUT 0 4 a DC 5V/24V IN connector f B/PB IN connector (BNC) Connect the DC connector of the supplied AC adaptor. Input connector for B of RGB signals and PB (blue color difference) of component signals. b / (power) switch The power is turned on or off. g R/PR IN connector (BNC) The monitor is turned on by pressing side . Input connector for R of RGB si
Inhaltszusammenfassung zur Seite Nr. 16
k Optional input slot For details, refer to the Interface Manual for An optional input adaptor can be installed according to Programmers (saved in the supplied CD-ROM, your system configuration (see page 18). Japanese and English only.) The upper slot is A and the lower slot is B. o DVI-D input connector (DVI-D) Press the A-1, A-2, B-1 or B-2 button to select the Inputs DVI Rev.1.0 applicable digital RGB signal. signal. To view the signals of the SXGA and higher resolution The BKM-243HS (HD/
Inhaltszusammenfassung zur Seite Nr. 17
3 Insert the DC IN connector into the DC 5V/24V IN connector on the bottom of this unit until it locks. Connecting the AC Power Cord Connect the supplied AC power cord as illustrated. Two kinds of AC plug holders are supplied with this unit. Use the AC plug holder that fits the AC power cord most securely. 1 Plug the AC power cord into the AC IN socket on the AC adaptor. Then, attach the AC plug holder to the AC power cord. AC IN socket AC power cord To remove the AC power cord First, pul
Inhaltszusammenfassung zur Seite Nr. 18
Installing the Input Removing the Adaptor Connector Cover Before installing the input adaptor, disconnect the power When the unit is shipped from the factory, a connector cord. cover is attached to the PARALLEL REMOTE connector and the SERIAL REMOTE connector (RJ- 1 Remove the panel of the optional input slot. 45). To use the connector, remove the connector cover as follows. Before removing the connector cover, disconnect the power cord. Connector cover 2 Insert the input adaptor into the s
Inhaltszusammenfassung zur Seite Nr. 19
Selecting the Default Settings + When you turn on the unit for the first time after – + purchasing it, select the area where you intend to use this – + unit from among the options. – MENU + – The default setting values for each area + + – – ENTER 2~3 3 1 5 1 4 1 Turn on the unit with the / (power) switch on 2 the bottom panel. 3 3 The SELECT SETTING screen appears. COLOR COMPONENT NTSC TEMP LEVEL SETUP 1North America S E L E C T S E T T I N G 1NORTH LOW BETA7.5 7.5 2Latin America N O R
Inhaltszusammenfassung zur Seite Nr. 20
2 If LATIN AMERICA is selected: Selecting the Menu PAL&PAL-N area Language L A T I N A M E R I C A P A L & P A L - N _ A R E A Argentina A R G E N T I N A P A R A G U A Y Paraguay U R U G U A Y You can select one of seven languages (English, French, N T S C & P A L - M A R E A Uruguay O T H E R A R E A German, Spanish, Italian, Japanese, Chinese) for NTSC&PAL-M area displaying the menu and other on-screen displays. “ENGLISH (English)” is selected in the default setting. Other a