more than 10cm
more than 10cm
more than 10cm
more than 15cm
Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Necessary Tools for Installation
1.Driver 5.Torque wrench(17mm,22mm,26mm) 9.Nipper 12.Reamer
2.Hacksaw 6.Pipe cutter 10.Gas leakage detector or
3.Hole core drill 7.Flaring tool soap-and-water solution
4.Spanner(17,19 and 26mm) 8.Knife 11.Measuring tape
Drawing for the install
Inhaltszusammenfassung zur Seite Nr. 2
HSU-09C03/VA(ZXF) HSU-12C03/VA(ZXF) HSU-18C03/V(ZXF) HSU-12H03/VB(ZXF) HSU-22C03/V(ZXF) HSU-22C03/V(ZF) HSU-22H03/V(ZF) HSU-22H03/V(ZXF) HSU-24C03/V(ZXF) HSU-09H03/VA(ZXF) HSU-12H03/VA(ZXF) HSU-18H03/V(ZXF) HSU-12H03/V(ZXF) HSU-24C03/V(ZF) HSU-24H03/V(ZF) HSU-24H03/V(ZXF) HSU-24HK0307 HSU-24HD0307 140 500 140 140 415 140 113.5 583 113.5 Floor fixing dimensions Floor fixing dimensions Floor fixing dimensions of the outdoor unit of the outdoor unit of the outdoor unit (Unit:mm) (Unit:mm) (Unit:mm)
Inhaltszusammenfassung zur Seite Nr. 3
Indoor unit Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. 3. F
Inhaltszusammenfassung zur Seite Nr. 4
Indoor unit 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Heat insulation material Piping signal wire Drain hose Lid for right piping Lid for left pip
Inhaltszusammenfassung zur Seite Nr. 5
1) (L) 2(N 1) (L) 2(N 1(L) 2(N) Indoor unit 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. Outdoor unit Indoor unit Indoor unit Indoor un
Inhaltszusammenfassung zur Seite Nr. 6
Outdoor unit 6.Easily-demount cleaning of indoor unit claw of the clip 1.Top inlet can be taken down Open the inlet grille, press the claw of the clip on the unit,then take down the top inlet.(according to figure 1) 2.Vertical flap can be taken down Figure 1 Overturn the vertical flap, press the claw of the clip ,then take Figure down vertical flap.(according to figure 2) 2 3.Horizontal louvers can be taken down After taking down vertical flap.Horizontal louvers are appeared,draw the middle lo
Inhaltszusammenfassung zur Seite Nr. 7
Outdoor unit 5.Installation instruction on the outdoor part of the fresh air device 1.Remove the four screws of fresh air box from the back cover. 2.Use six screws to fix fresh air box onto the designated position on the outdoor unit. 3.Remove two screws of the pipe junction of the fresh air box, then insert the flared departure of the change for fresh air tube into the pipe junction and then fix with the screws. 4.Use four screws to fix the fresh air box onto the back cover, as illustrated:
Inhaltszusammenfassung zur Seite Nr. 8
1.Power Source Installation The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible. 2.Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. A Pipe diameter( ) Size A(mm) Liquid side 6.3