Inhaltszusammenfassung zur Seite Nr. 1
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09LH13
HSU-12LH13
Please read this operation manual before using the air conditioner
No.001050
Inhaltszusammenfassung zur Seite Nr. 2
Cautions Safety Instructions and Warnings Disposal of the old air conditioner Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully. The User's Guide contains very impor- in order to avoid the risk of child entrapment. tant observations relating to the assembly, operation and maintenance of the air It must be noticed that
Inhaltszusammenfassung zur Seite Nr. 3
Cautions 7. The appliance is not intended for use Do not obstruct or cover the ventilation by young children or infirm persons grille of the air conditoner.Do not put fingers without supervision. or any other things into the inlet/outlet and swing louver. 8. Young children should be supervised to ensure that they do not play with Do not allow children to play with the air the applience. conditioner.In no case should children be allowed to sit on the outdoor unit. 9.Ple
Inhaltszusammenfassung zur Seite Nr. 4
Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water
Inhaltszusammenfassung zur Seite Nr. 5
Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT OFF ENFORCEMENT Connect power supply cord Use the proper voltage Do not use power supply cord to the outlet completely extended or connected in halfway STRICT STRICT PROHIBITION ENFORCEMENT ENFORCEMENT Do not insert objects into the air Do not use power supply cord Take care not to damage inlet or outlet. in a bun
Inhaltszusammenfassung zur Seite Nr. 6
Parts and Functions Indoor unit Display board Inlet Air filter (inside) Anion generator (inside) Inlet grille Vertical flap (Use remote controller to adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) Actual inlet grille may vary from the one shown in the manual according to the product purchased Outdoor unit 1 3 OUTLET CONNECTING PIPING AND ELECTRICAL WIRING 2 4 INLET DRAIN HOSE 5
Inhaltszusammenfassung zur Seite Nr. 7
Parts and Functions 19 18 34 24 16 17 9. HEALTH button Used to set healthy operation. 10. ON/OFF button Used for unit start and stop. 11. TIMER ON display 12. FAN SPEED display LOW MED HI AUTO 13. LOCK display 14. SWING UP/DOWN display 28 FRESH 15. SLEEP display 16. HEALTH display 17.FRESH AIR display STERILIZE 18. Operation mode display Operation mode AUTO COOL DRY FAN 33 Remote controller Display board 19.Singal sending display 20. UV light degerming function display 21. Left/right air flow
Inhaltszusammenfassung zur Seite Nr. 8
Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in FRESH remote controller, clock should be adjusted as follows: 1. Press CLOCK button,"AM" or "PM" flashes. STERILIZE 2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly. 3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working. Remote controller's operatio
Inhaltszusammenfassung zur Seite Nr. 9
Operation HEALTH operation 1.Unit start Press ON/OFF on the remote controller, unit starts. Remote controller 2.Health anion function Press HEALTH button. For each press, is displayed. Air conditioner starts health anion function operation. For twice press, disappears,the operation stops. When indoor fan motor is running, it has healthy process function. (It's available under any mode) FRESH BRIEF INTRODUCTION TO HEALTH ANION FUCTION The anion generator in the air conditioner can g
Inhaltszusammenfassung zur Seite Nr. 10
Operation Auto Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select Auto operation 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting FRESH increase 1 C,if kept depressed, it will increase rapidly STERILIZE Every time the button is pressed, temp.setting decrease 1 C,if kept dep
Inhaltszusammenfassung zur Seite Nr. 11
Operation Cool Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select COOL operation 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting FRESH increase 1oC,if kept depressed, it will increase rapidly STERILIZE Every time the button is pressed, temp.setting decrease 1oC,if kept dep
Inhaltszusammenfassung zur Seite Nr. 12
Operation Dry Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select DRY operation 3.Select temp.setting Press TEMP. button FRESH Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly STERILIZE Every time the button is pressed, temp.setting decrease 1oC,if kept depre
Inhaltszusammenfassung zur Seite Nr. 13
Operation Fan Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select FAN operation 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: FRESH Remote controller: STERILIZE LOW MED HI 4.Unit stop Press ON/OFF button, the unit stops. About FAN operation In FAN operation mode, the unit w
Inhaltszusammenfassung zur Seite Nr. 14
Operation Air Flow Direction Adjustment 1.Status display of air sending Vertical flap Horizontal louvers Pos.1 Pos.1 Pos.2 Pos.2 Pos.3 Pos.3 FRESH Pos.4 Pos.4 STERILIZE Pos.5 Pos.5 Pos.6 Pos.6 (Auto swing) Pos.7 Pos.8 2.Up and down air flow direction For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN: Pos.1 Pos.2 Pos.3 Pos.4 Pos.6 remote controller: AUTO: Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 remote con
Inhaltszusammenfassung zur Seite Nr. 15
Operation Sleep Operation Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. SLEEP operation starts SLEEP operation stops Use of SLEEP function Approx.6hrs After the unit starts, set the operation status, then press SLEEP button before which the Rises 1OC 1 hr clock must be adjusted and time being set. Operation Mode Rises 1OC 1 hr 1. In COOL,DRY mode 1 hours after SLEEP mode starts, temp. will Unit stop Temp.setting be
Inhaltszusammenfassung zur Seite Nr. 16
Operation Timer On/Off Operation Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Remote Controller Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash. 3.T
Inhaltszusammenfassung zur Seite Nr. 17
Operation Timer On-Off Operation Set clock correctly before starting TIMER operation. Remote Controller 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON - OFF). " "will flash. 3.Time setting Press H
Inhaltszusammenfassung zur Seite Nr. 18
Operation Emergency and Test Operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature. When machine is running in emergency, the set value of temperature and wind speed couldn't be altered; meanwhile, i
Inhaltszusammenfassung zur Seite Nr. 19
Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch. OFF 20
Inhaltszusammenfassung zur Seite Nr. 20
Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral Do not use water, wipe the controller with a detergent diluted with water.Wring the water dry cloth.Do not use glass cleaner or chemical out of the cloth before wiping.then wipe off cloth. the detergent completely. Do not use the following for cleani