Inhaltszusammenfassung zur Seite Nr. 1
Room Air Conditioner
Climatiseur individuel
Aire acondicionado
de uso doméstico
User & Care Guide
HWR05XCM HWE10XCN
Guide d'utilisation et d'entretien
HWE06XCN HWE12XCN
HWE08XCN
Guía de uso y cuidado
°F/°C
Hr
MODE SPEED TIMER
FAN HIGH ON
MED OFF
ENERGY
SAVE
COOL LOW SLEEP
DEHUM AUTO COOL
TEMP/TIME
FILTER
RESET
CLEAN FILTER
POWER
AUTO RESTART
Design may vary by model number. La configuration peut varier selon le El diseño puede variar conforme al
numéro de modèle. número de modelo
This user ma
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
ENGLISH TABLE OF CONTENTS SAFETY INFORMATION............................................................................................................. 2 Important Safety Precautions ................................................................................................ 2-3 Operational Safety & Warnings .................................................................................................. 4 INSTALLATION REQUIREMENTS .......................................................
Inhaltszusammenfassung zur Seite Nr. 4
ENGLISH IMPORTANT SAFETY PRECAUTIONS WARNING THE INFORMATION IN THIS USE & CARE GUIDE MUST BE FOLLOWED TO MINIMIZE THE RISK OF PERSONAL INJURY, FIRE, ELECTRIC SHOCK OR OTHER UNSAFE CONDITIONS. THE INSTRUCTIONS IN THIS USE & CARE GUIDE ARE NOT MEANT TO INCLUDE EVERY POSSIBLE CONDITION OR SITUATION THAT MAY OCCUR. USE CAUTION AND CARE WHEN INSTALLING, OPERATING AND CLEANING THE AIR CONDITIONER. 1. Use this air conditioner only for its intended application as described in this Use & Car
Inhaltszusammenfassung zur Seite Nr. 5
ENGLISH IMPORTANT SAFETY PRECAUTIONS 8. T his air conditioner contains R410a refrigerant and requires certified technicians to use the proper equipment, tools and safety standards that are approved for this refrigerant. Use only equipment certified for R410a refrigerant. In addition, under federal law, all refrigerant must be properly removed from the air conditioner prior to its disposal. For responsible disposal of the product please contact or your local municipality for recycling optio
Inhaltszusammenfassung zur Seite Nr. 6
ENGLISH OPERATIONAL SAFETY & WARNINGS 1. This air conditioner contains no consumer serviceable parts. If you have problems or questions regarding the operation of your air conditioner always call Haier Customer Service: 1-877-337-3639. 2. Be sure that the air conditioner is properly and securely installed in the window according to the installation instructions included in this Use & Care Guide. 3. DO NOT drill any holes in the base or sides of the air conditioner. 4. DO NOT place finger
Inhaltszusammenfassung zur Seite Nr. 7
ON/OFF MODE SPEED TIMER TEMP/TIME TEMP/TIME ENGLISH TOOLS AND PARTS Read and follow the instructions provided with any tools listed here. TOOLS NEEDED Phillips head screwdriver Level Drill and 1/8” bit Scissors Tape measure Pencil PARTS SUPPLIED: Check that all parts for your specific air conditioner are included in the parts package. NOTE: If parts are missing, call Haier Customer Service: 1-877-337-3639. 5,000 BTU 6,000 BTU 10,000 BTU IMAGE PART 8,000 BTU 12,000 BTU Top channel 1
Inhaltszusammenfassung zur Seite Nr. 8
ENGLISH LOCATION REQUIREMENTS IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. THE LOCATION SHOULD PROVIDE: • A grounded electrical outlet within 6 ft. (183 cm) of where the power supply cord exits the air conditioner, for models: HWR05XCM HWE06XCN HWE08XCN A grounded electrical outlet within 4 ft. (122 cm) of where the power supply cord exits the air
Inhaltszusammenfassung zur Seite Nr. 9
ENGLISH ELECTRICAL REQUIREMENTS WARNING ELECTRICAL SAFETY and WARNINGS 1. DO NOT cut or remove the grounding prong on the attached power supply cord. Doing so may cause sparks or fire, and voids all warranties. For safety purposes the air conditioner must be properly grounded. 2. To avoid a fire hazard or possible electric shock, DO NOT use an adapter plug, extension cord, surge protectors, or multi-outlet adapters with the air conditioner. 3. The power supply cord is equipped with a 3-pro
Inhaltszusammenfassung zur Seite Nr. 10
ENGLISH ELECTRICAL REQUIREMENTS cont. Fig. 3 REQUIRED GROUNDING METHOD (See Fig.3) This air conditioner must be grounded. This air conditioner is equipped with a power supply cord that has a 3 prong grounding plug. The power supply cord must be plugged into a mating, grounded 3 prong outlet, and grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to contact a qualified electrician and ensure that a properly grou
Inhaltszusammenfassung zur Seite Nr. 11
ENGLISH ELECTRICAL REQUIREMENTS cont. WARNING • Electrical shock hazard • Do not use a plug adapter, extension cord, • Plug into a mating, grounded 3 prong surge protector, or multi-outlet adapter outlet. • F ailure to follow these instructions can • Do not remove the ground prong from the result in injury, fire, or electrical shock. power supply cord. TO TEST YOUR POWER SUPPLY CORD: 1. Plu g power supply cord into a mating, grounded 3 prong outlet. Fig. 5 (See Fig.5) 2. Press RESET (on
Inhaltszusammenfassung zur Seite Nr. 12
ENGLISH UNPACKING THE AIR CONDITIONER WARNING EXCESSIVE WEIGHT HAZARD When moving or lifting the air conditioner, use two or more people. Wear gloves when handling the air conditioner to protect against possible sharp edges and metal fins. REMOVE PACKAGING MATERIALS Remove packaging materials. Save the carton and the foam packaging for storing the unit when • not in use. NOTE: There are NO internal packing materials inside the air conditioner to remove―Do Not open the cabinet. Handle t
Inhaltszusammenfassung zur Seite Nr. 13
ENGLISH PREPARING THE AIR CONDITIONER cont. INSTALL SIDE CURTAINS NOTE: Attach side curtains to the air conditioner before placing the unit in the window. 1. Place the tabbed side of the side curtain in the track on the right-hand side of the air conditioner cabinet. (See Fig.9) Fig. 9 Fig. 10 TABBED SIDE OF LOCK EDGE SIDE SIDE CURTAIN OF SIDE CURTAIN 2. Slide the tabbed side of the side curtain down over Fig. 11 all 3 tracks until the curtain is aligned with the top and bottom of th
Inhaltszusammenfassung zur Seite Nr. 14
ENGLISH PREPARING THE WINDOW 1. Measure the width of the window opening. (See Fig.13) 2. Mark the center line on the inside of the windowsill with a pencil. (See Fig.14) WIDTH OF CENTER LINE WINDOW OPENING Fig. 13 HEIGHT Fig. 14 WIDTH WIDTH WIDTH CENTER NOTES AND WARNINGS: Be sure your air conditioner does not fall out of the window opening during installation • or removal. Do not block the air discharge or air intake areas on the front panel. • Do not block the louvers on the outsid
Inhaltszusammenfassung zur Seite Nr. 15
ENGLISH COMPLETING THE INSTALLATION Fig. 17 ATTACH SIDE CURTAINS TO WINDOW 1. Pull the left-hand curtain and frame out until it fits flush to the side of the window frame. (See Fig.17) 2. Use a 1/8” drill bit to drill a starter hole through the top hole in the side curtain and into the window sash. 3. Insert one (1) 1" wood screws through the top hole of the left hand curtain and into the window sash. (See Fig.18) 4. Repeat for the right-hand curtain. 5. Use a 1/8" drill bit to drill a st
Inhaltszusammenfassung zur Seite Nr. 16
ENGLISH STARTING THE AIR CONDITIONER °F/°C Hr MODE SPEED TIMER TIMER MODE SPEED FAN HIGH ON ENERGY MED OFF SAVE COOL LOW SLEEP DEHUM AUTO COOL TEMP/TIME FILTER RESET TEMPERATURE / TIME FILTER RESET CLEAN FILTER CLEAN FILTER INDICATOR POWER POWER AUTO RESTART Operating your air conditioner properly helps you to obtain the best possible results. This section explains how to operate this air conditioner. IMPORTANT: When you turn off the air conditioner , either at the control panel or with the re
Inhaltszusammenfassung zur Seite Nr. 17
ENGLISH STARTING THE AIR CONDITIONER cont. 1. Carefully remove the clear plastic film from the control panel. 2. Press POWER once to turn on the air conditioner. NOTE: W hen the air conditioner is first plugged in, the LED display will show “88” for 3 seconds. After the air conditioner is turned on for the first time, the display will show the ° temperature 72 F and the fan is automatically set to Low speed and the Mode indicator will show ENERGY SAVE. NOTE: To switch the temperature display
Inhaltszusammenfassung zur Seite Nr. 18
ENGLISH STARTING THE AIR CONDITIONER cont. SPEED 1. Press FAN SPEED until you see the indicator light come on next to the desired setting. 2. Choose High, Med, Low or Auto Cool °F/°C Hr HIG H ―For maximum cooling MED ―For normal cooling LOW ―For minimum cooling MODE SPEED TIMER AUTO COOL – A djusts the fan speed automatically to provide ideal cooling based on the room temperature. FAN HIGH ON TIMER ENERGY MED OFF SAVE To set the air conditioner to turn off between 1 hour and 24 hour
Inhaltszusammenfassung zur Seite Nr. 19
ENGLISH STARTING THE AIR CONDITIONER cont. TO CLEAR TIMER PROGRAM: NOTE: Air conditioner can be either on or off. Press TIMER until Timer indicator light turns off. TO VIEW OR CHANGE THE REMAINING TIME (IN HOURS): TIMER OFF 1. Press the TEMP/TIME up or down arrow button to increase or decrease the time. 2. After 5 seconds, the display will show the remaining time to Timer OFF. TIMER ON 1. The display will show the remaining time. 2. Press the TEMP/TIME up or down arrow button to increase or decr
Inhaltszusammenfassung zur Seite Nr. 20
ENGLISH STARTING THE AIR CONDITIONER cont. FILTER RESET This feature automatically notifies you that the air filter must be cleaned. The indicator light will come on after 240 hours of operation. Clean the air filter (refer to Care and Cleaning), place it back in the front panel, and press the Filter Reset button. The light will turn off. USING THE REMOTE CONTROL NOTE: The raised dots are Braille for the visually impaired. (See Fig.22) ON/OFF Remote control may differ in appearance from the image s