Inhaltszusammenfassung zur Seite Nr. 12
ENGLISH ELECTRICAL REQUIREMENTS cont. WARNING • Electrical shock hazard • Do not use a plug adapter, extension cord, • Plug into a mating, grounded 3 prong surge protector, or multi-outlet adapter outlet. • Failure to follow these instructions can • Do not remove the ground prong from the result in injury, fire, or electrical shock. power supply cord. IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you hav
Inhaltszusammenfassung zur Seite Nr. 13
ELECTRICAL REQUIREMENTS cont. TO TEST YOUR POWER SUPPLY CORD: 1. Plug power supply cord into a mating, grounded 3 prong outlet. (See Fig.3) Fig. 3 2. Press RESET (on some devices, a green light will turn on). 3. Pr ess TEST (listen for click; Reset button will trip, and on some devices, a green light will turn off). 4. Press and release RESET (listen for click; Reset button will latch, and on some devices, a green light will turn on). The power supply cord is ready for operation. NOTE: T
Inhaltszusammenfassung zur Seite Nr. 14
ENGLISH UNPACKING THE AIR CONDITIONER WARNING EXCESSIVE WEIGHT HAZARD When moving or lifting the air conditioner, use two or more people. Wear gloves when handling the air conditioner to protect against possible sharp edges and metal fins. REMOVE PACKAGING MATERIALS Remove packaging materials. Save the carton and the foam packaging for storing the unit when • not in use. NOTE: T here are NO internal packing materials to remove—Do Not open the cabinet. Handle the air conditioner gently.
Inhaltszusammenfassung zur Seite Nr. 15
PREPARING THE AIR CONDITIONER cont.: ESA415 / ESA418 Assemble and install side curtains and top channel (See Fig.7) FOR MODELS: ESA415M ESA418M 7/16" Self Tapping Screws Fig. 6 Top Channel Front 1. Install the top channel with four (4) 7/16” self-tapping screws. (See Fig.6) 2. Slide left-hand curtain assembly into left side of top and bottom channels. Repeat for right- hand curtain assembly. (See Fig.7) 3. Fasten curtain retainer strips to the sides of the cabinet with eight (8) 7/16” self-t
Inhaltszusammenfassung zur Seite Nr. 16
ENGLISH PREPARING THE AIR CONDITIONER cont.: ESA415 / ESA418 1. Measure the width of the window opening. (See Fig.8) 2. Mark the center line on the inside of the windo wsill with a pencil. (See Fig.9) WIDTH OF CENTER LINE WINDOW OPENING HEIGHT Fig. 8 Fig. 9 WIDTH WIDTH WIDTH CENTER NOTES AND WARNINGS: • Be sure your air conditioner does not fall out of the opening during installation or removal. • A gr ounded electrical outlet must be within 4 ft. (122 cm) of where the power supply cord exit
Inhaltszusammenfassung zur Seite Nr. 17
PREPARING THE WINDOW: ESA415 / ESA418 2. Expand bo th curtains so they contact the side window frame. Install four (4) 1” wood screws, two (2) in the upper corners of the curtains and two (2) in the lower corners of the curtain. (See Fig.11) 3. Use thr ee (3) 1” wood screws to secure the cabinet, 1 to the window sash, 2 to the window sill. (See Fig.11) Fig. 11 4. Install 2-1/2” leveling bolts to the left and right brackets. (See Fig.12) Window Sash 5. Secur e cabinet to left and right bra
Inhaltszusammenfassung zur Seite Nr. 18
ENGLISH COMPLETING THE INSTALLATION: ESA415 / ESA418 COMPLETE THE INSTALLATION Fig. 14 1. Uncoil the included foam seal. (See Fig.14) 2. Insert the foam seal behind the top of the lower window sash and against the glass of the upper window. (See Fig.15) (A) Top of lower (B)Foam seal A. Top of lower window sash window sash B. Foam seal Fig. 15 3. Place the window lock bracket as shown. Use a 1⁄8” drill bit to drill a starter hole through the hole in the window lock bracket and into the u
Inhaltszusammenfassung zur Seite Nr. 19
PREPARING THE AIR CONDITIONER: ESA424 Assemble and install side curtains and top channel (See Fig.19) FOR MODEL: ESA424 7/16" Self Tapping Screws Fig. 19 Top Channel Front 1. Install the top channel with four (4) 7/16” self-tapping screws. (See Fig.19) 2. Slide left-hand curtain assembly into left side of top and bottom channels. Repeat for right- hand curtain assembly. (See Fig.20) 3. Fasten curtain retainer strips to the sides of the cabinet with six (6) 7/16” self-tapping screws. (3) Self
Inhaltszusammenfassung zur Seite Nr. 20
ENGLISH PREPARING THE AIR CONDITIONER: ESA424 1. Measure the width of the window opening. (See Fig.21) 2. Mark the center line on the inside of the windo wsill with a pencil. (See Fig.22) WIDTH OF CENTER LINE WINDOW OPENING HEIGHT Fig. 21 Fig. 22 WIDTH WIDTH WIDTH CENTER NOTES AND WARNINGS: • Be sure your air conditioner does not fall out of the opening during installation or removal. • A gr ounded electrical outlet within 4 ft. (122 cm) of where the power supply cord exits the air conditio
Inhaltszusammenfassung zur Seite Nr. 1
Room Air Conditioner
Climatiseur individuel
Aire acondicionado
de uso doméstico
User & Care Guide
ESA415M
Guide d'utilisation et d'entretien
ESA418M
ESA424K
Guía de uso y cuidado
Design may vary by model number. La configuration peut varier selon le El diseño puede variar conforme al
numéro de modèle. número de modelo
This user manual is to be only use for Ce guide d'utilisation doit être Este manual del usuario sólo se debe
electronic control 14,500 BTU, 18,000 utilisé strictement avec les
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
PRODUCT REGISTRATION Thank you for purchasing our Haier product. This easy-to-use manual will guide Model number you in getting the best use of your product. Remember to record the model and serial Serial number numbers. They are on a label on the side of your unit. Date of purchase Staple your receipt to your manual. You will need it to obtain warranty service. ENGLISH
Inhaltszusammenfassung zur Seite Nr. 4
ENGLISH TABLE OF CONTENTS SAFETY INFORMATION............................................................................................................. 2 Important Safety Precautions ................................................................................................ 2-3 Operational Safety & Warnings .................................................................................................. 4 INSTALLATION REQUIREMENTS .......................................................
Inhaltszusammenfassung zur Seite Nr. 5
IMPORTANT SAFETY PRECAUTIONS WARNING THE INFORMATION IN THIS USE & CARE GUIDE MUST BE FOLLOWED TO MINIMIZE THE RISK OF PERSONAL INJURY, FIRE, ELECTRIC SHOCK OR OTHER UNSAFE CONDITIONS. THE INSTRUCTIONS IN THIS USE & CARE GUIDE ARE NOT MEANT TO INCLUDE EVERY POSSIBLE CONDITION OR SITUATION THAT MAY OCCUR. USE CAUTION AND CARE WHEN INSTALLING, OPERATING AND CLEANING THE AIR CONDITIONER. 1. Use this air conditioner only for its intended application as described in this Use & Care Guide.
Inhaltszusammenfassung zur Seite Nr. 6
ENGLISH IMPORTANT SAFETY PRECAUTIONS 8. This air conditioner contains R410a refrigerant and requires certified technicians to use the proper equipment, tools and safety standards that are approved for this refrigerant. Use only equipment certified for R410a refrigerant. In addition, under federal law, all refrigerant must be properly removed from the air conditioner prior to its disposal. READ AND FOLLOW THE SAFETY INSTRUCTIONS CAREFULLY. SAVE THESE INSTRUCTIONS SAFETY INFORMATION PAGE
Inhaltszusammenfassung zur Seite Nr. 7
OPERATIONAL SAFETY & WARNINGS 1. This air conditioner contains no consumer serviceable parts. If you have problems or questions regarding the operation of your air conditioner always call Haier Customer Service: 1-877-337-3639. 2. Be sure that the air conditioner is properly and securely installed in the window according to the installation instructions included in this Use & Care Guide. 3. DO NOT drill any holes in the base or sides of the air conditioner. 4. DO NOT place fingers or ob
Inhaltszusammenfassung zur Seite Nr. 8
ENGLISH ON/OFF MODE SPEED TIMER TEMP/TIME TEMP/TIME TOOLS AND PARTS Read and follow the instructions provided with any tools listed here. TOOLS NEEDED Phillips head screwdriver Socket wrench & sockets Pliers Flat-blade screwdriver Tape measure Adjustable wrench Scissors Cordless drill and 1/8” bit Level Pencil PARTS SUPPLIED: Check that all parts for your specific air conditioner are included in the parts package. NOTE: If parts are missing, call Haier Customer Service: 1-87
Inhaltszusammenfassung zur Seite Nr. 9
LOCATION REQUIREMENTS IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. The site of installation should provide: • A grounded electrical outlet within 4 ft. (122 cm) of where the power cord exits the air conditioner. NOTE: Do no t use an extension cord, plug adapter, surge protector or multi-outlet adapter. • Free movement of air in the room to be cooled. • A
Inhaltszusammenfassung zur Seite Nr. 10
ENGLISH ELECTRICAL REQUIREMENTS WARNING ELECTRICAL SAFETY and WARNINGS 1. DO NOT cut or remove the grounding prong on the attached power supply cord. Doing so may cause sparks or fire, and voids all warranties. For safety purposes the air conditioner must be properly grounded. 2. To avoid a fire hazard or possible electric shock, DO NOT use an adapter plug, extension cord, surge protectors, or multi-outlet adapters with the air conditioner. 3. T he power supply cord is equipped with a 3-p
Inhaltszusammenfassung zur Seite Nr. 11
ELECTRICAL REQUIREMENTS cont. POWER SUPPLY CORD (See Fig.1) Wiring Requirements Fig. 1 For model ESA415M ESA415 ESA418 ESA424 • 115-volt (103.5 minimum to 126.5 maximum) ESA415M • 15-amp time-delay grounded fuse or circuit breaker • Use on single outlet circuit only. 115V 230V 230V 15 Amp 15 Amp 20 Amp For model ESA418M ESA415 ESA418 ESA424 • 230/208 volt (187 min. to 253 max.) • 15-amp time-delay fuse or circuit breaker ESA418M • Use on single outlet circuit only. 115V 230V 230V 15 Amp 1