Inhaltszusammenfassung zur Seite Nr. 1
R
VIDEO CASSETTE RECORDER
INSTRUCTIONS
SR-9090U
SR-9090U
REC
REC REC
STOP EJECT OPERATE
CHECK OPERATE
HDR
For Customer Use:
Enter below the Serial No. which is
located on the rear of cabinet. Retain
this information for future reference.
This instruction manual
Thank you for purchasing this JVC product.
is made from 100%
Before operating this unit, please read
Model No. SR-9090U
recycled paper.
the instructions carefully to ensure the
Serial No.
be
Inhaltszusammenfassung zur Seite Nr. 2
SAFETY PRECAUTIONS CAUTION ATTENTION RISQUE D’ELECTROCUTION RISK OF ELECTRIC SHOCK NE PAS OUVRIR DO NOT OPEN ATTENTION: POUR EVITER TOUT RISQUE D’ELECTROCUTION CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, NE PAS OUVRIR LE BOITER. DO NOT REMOVE COVER (OR BACK). AUCUNE PIECE INTERIEURE N’EST NO USER-SERVICEABLE PARTS INDIDE. A REGLER PAR L’UTILISATEUR. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL SE REFERER A UN AGENT QUALIFIE EN CAS DE PROBLEME. Le symbole de l’éclair à l’intérieur d’un trian
Inhaltszusammenfassung zur Seite Nr. 3
Ó OPERATION LOCK By engaging the operation lock system [LOCK], you can prevent accidental or deliberate interference with recording operation or power supply. When this function is activated, all operation buttons are disabled. However, you can still control the recorder with the remote control. SR-9080U REC REC STOP REC EJECT OPERATE CHECK OPERATE HDR RESET/ CANCEL ON SCREEN REW REVERSE PAUSE PLAY FF SHIFT TRACKING V. LOCK TIMER SEARCH DISPLAY LOCK CNT RESET MENU TIME MODE + + – SET + – – FIE
Inhaltszusammenfassung zur Seite Nr. 4
4
Inhaltszusammenfassung zur Seite Nr. 5
CONTENTS 1 INTRODUCTION 7 PLAYBACK AND SPECIAL-EFFECTS PLAYBACK 1-1 Major Features ............................................. 6 7-1 Preparation................................................. 46 1-2 Periodical Maintenance ................................ 7 7-2 Playback..................................................... 46 1-3 Precautions .................................................. 7 7-3 Special-Effects Playback ........................... 47 1-4 Daily Inspection ....................
Inhaltszusammenfassung zur Seite Nr. 6
1 INTRODUCTION 1-1 Major Features 5 Extended timelapse recording for up to 960 hours 5 Tape position search function Recording times are selectable from 2 hours (SP mode), You can automatically search the start of an alarm 6 hours (EP mode) and 24/48/72/120/168/240/480/960 recording or search for a recording made at a specified (Timelapse mode) (when T-120 tape is used). date and time. 5 High-resolution recording 5 Recording check function Delivers horizontal resolution of more than 40
Inhaltszusammenfassung zur Seite Nr. 7
1 INTRODUCTION 1-2 Periodical Maintenance This VCR incorporates precision mechanical parts which will collect dirt over time and ultimately deteriorate and wear out. Over long periods of use, dirt and dust accumulates on the heads, drums and tape transport mechanisms. Dust which penetrates the VCR (especially during outdoor use) also promotes the wear and deterioration of mechanical parts by causing poor contact between tape and heads. This also prevents the VCR from maintaining video and audi
Inhaltszusammenfassung zur Seite Nr. 8
1 INTRODUCTION 1-3 Precautions Video cassette • Only use video cassette bearing the mark. • To prevent accidental erasure of a recorded tape, break the erasure prevention tab on the cassette. To use a cassette with a broken tab, place a piece of cellophane tape over the broken tab. Erasure prevention tab • Video cassettes cannot be used upside down. • Leaving the tape in a partially wound condition for a long Timelapse recording is performed over very time may damage the tape. Rewind the ta
Inhaltszusammenfassung zur Seite Nr. 9
2 CONTROLS AND CONNECTORS 2-1 Front Panel 7 6 5 4 3 SR-9090U REC REC STOP REC EJECT OPERATE OPERATE CHECK HDR RESET/ CANCEL ON SCREEN REW REVERSE PAUSE PLAY FF SHIFT TRACKING V. LOCK TIMER SEARCH DISPLAY LOCK CNT RESET MENU TIME MODE + + – SET + – – FIELD REV FIELD ADV 8 9 10 11 12 13 14 15 2 1 1 [OPERATE] button 9 [REVERSE] button Press to turn the operating mode ON/OFF. When this button Starts reverse playback when pressed in any mode except is ON, the OPERATE indicator t lights and the
Inhaltszusammenfassung zur Seite Nr. 10
2 CONTROLS AND CONNECTORS 2-1 Front Panel 24 25 26 SR-9090U REC REC REC STOP EJECT OPERATE OPERATE CHECK HDR RESET/ CANCEL ON SCREEN REW REVERSE PAUSE PLAY FF SHIFT TRACKING MENU TIME MODE V. LOCK TIMER SEARCH DISPLAY LOCK CNT RESET – + – + – + SET FIELD REV FIELD ADV 16 17 18 19 20 21 22 23 ^ [SEARCH] button w [TIME MODE/SET +/–] buttons Use to search the alarm recorded section or a section • Use to select the recording and playback speed mode. recorded at a specified date and time. In t
Inhaltszusammenfassung zur Seite Nr. 11
2 CONTROLS AND CONNECTORS 2-2 Display 10 1 6 7 8 9 11 12 13 13 2 3 4 5 1 Operation mode display 5 Recording/playback speed display Shows the operation modes. • Normally shows the recording/playback speed mode set with the [TIME MODE] button. • Shows the following indications in the Alarm Search mode. During alarm search: Shows the specified alarm number Fast- Timelapse Playback Recording Rewind forward playback (example: AL12) During alarm scan: Shows the alarm scan mode (ALSC). During date/
Inhaltszusammenfassung zur Seite Nr. 12
2 CONTROLS AND CONNECTORS 2-1 FRONT PANEL 2-3 Rear Panel 4 6 8 1 AC~IN RS-232C AC120V~50/60Hz VIDEO AUDIO Y/C ALARM COM CLOCK SERIES CAM SW ALARM OUT IN REC OUT RESET IN REC IN IN ALARM TAPE WARNING CLOCK SERIES COM RESET END OUT OUT RESET OUT REC OUT REMOTE MIC OUT COM CAM SW ALARM ALARM CLOCK SERIES REC OUT RESET IN REC IN OUT IN ALARM TAPE WARNING CLOCK SERIES 2 3 5 7 10 9 COM RESET END OUT OUT RESET OUT REC OUT 1112 1314 15 1617 20 22 18 19 21 1 [AC IN] connector 9 [Y/C OUT] connec
Inhaltszusammenfassung zur Seite Nr. 13
2 CONTROLS AND CONNECTORS 2-3 Rear Panel ^ [TAPE END OUT] tape end signal output terminal q [SERIES REC IN] series recording/VCR activation Outputs a signal when the tape ends during recording. signal input terminal If the menu switch on the screen is set, signals are output when the signal from an external control device. specified tape reel counter value is exceeded. Select the input signal with the menu switche
Inhaltszusammenfassung zur Seite Nr. 14
3 CONNECTIONS 3-1 Connecting to a Camera CCD Microphone Amplifier Video camera RCA BNC 4pin Microphone M3.5 mini- jack AC~IN RS-232C AC120V~50/60Hz Provided power cord VIDEO AUDIO Y/C CAM SW ALARM ALARM CLOCK SERIES COM RESET IN OUT IN REC OUT REC IN IN ALARM TAPE WARNING CLOCK SERIES COM RESET END OUT OUT RESET OUT REC OUT REMOTE MIC OUT AC 120 V 4pin 50/60 Hz ALARM IN COM BNC RCA Alarm sensor Monitor TV 1 Connect the monitor’s video/audio input connectors to the SR-9090U’s video/audio ou
Inhaltszusammenfassung zur Seite Nr. 15
3 CONNECTIONS 3-2 System Using Sequential Switcher Video camera CCD 1 2 3 4 5 6 Alarm sensor input Alarm sensor 1 2 3 4 5 6 CCD Alarm signal output Sequential switcher Video output Camera switching CCD signal input CCD Microphone CCD CCD RCA BNC Amplifier AC~IN RS-232C AC120V~50/60Hz VIDEO AUDIO Provided Y/C ALARM CLOCK SERIES CAM SW AL
Inhaltszusammenfassung zur Seite Nr. 16
3 CONNECTIONS 3-3 Connecting the Rear Panel Input/Output Terminal Connections [CAM SW OUT] camera switching signal output terminal [ALARM IN] alarm signal input terminal ALARM CAM SW IN COM OUT COM Sequential switcher Sequential switcher alarm output camera switching terminal signal input [ALARM RESET] alarm reset terminal [ALARM REC OUT] alarm recording mode signal output terminal ALARM ALARM ALARM RESET REC OUT COM RESET COM Alarm lamp External Vcc interface Switch Vcc: 5V–12V Switch [
Inhaltszusammenfassung zur Seite Nr. 17
4 ON-SCREEN/MENU SWITCHES 4-1 On-Screen Display Displays the time date (date and time), recording speed, number of alarms and number of power losses (power failures) on screen in the Stop mode, Record mode and Record-Pause mode. During recording, the on-screen data is recorded together with video signals. • The on-screen display position can be moved with the [ON SCREEN] buttons. • The type of data shown and display brightness can be selected on the screen. [ON SCREEN
Inhaltszusammenfassung zur Seite Nr. 18
4 ON-SCREEN/MENU SWITCHES 4-2 Main Menu Display You can display date and time data recorded when an alarm input or power failure occurs, as well as the hour meter (drum rotating time) by selecting the desired item in the main menu. The date/time setting screen, menu switch setting screen for each application, and timer recording program setting screen can also be displayed by selecting the desired item in the main menu. Date/time setting, menu switch setting and hour meter can be checked on th
Inhaltszusammenfassung zur Seite Nr. 19
4 ON-SCREEN/MENU SWITCHES 4-3 Date and Time Setting The time/date generator and timer recording will not function if the time and date are not set. Set the month/day/year, hour/minute and Summer Time Compensation ON/OFF on the CLOCK SET screen. The setting can be checked even on the display. SR-9090U RESET/ CANCEL ON SCREEN REC SHIFT REC STOP REC EJECT OPERATE OPERATE CHECK MENU TIME MODE HDR RESET/ CANCEL ON SCREEN REW REVERSE PAUSE PLAY FF SHIFT TRACKING V. LOCK TIMER SEARCH DISPLAY LOCK
Inhaltszusammenfassung zur Seite Nr. 20
4 ON-SCREEN/MENU SWITCHES 4-3 Date and Time Setting Summer Time Compensation • When setting the time, make sure the item is set to “OFF”. When this unit is shipped, this item is set to “OFF”. Standard time During daylight savings time 1 Set the clock to the actual time. 1 Set the time with a one-hour delay. 2 When daylight savings start, set the 2 After setting the time, set the item to item to “ON”. “ON”. • The time advances one hour on the display. •