Inhaltszusammenfassung zur Seite Nr. 1
Multi-Functional Cleaning
MODEL: CMPS2
10070560
CMPS2E
10070570
Operating Instructions (ENG)
86305210 –F
02/19/09
Inhaltszusammenfassung zur Seite Nr. 2
MACHINE DATA LOG/OVERVIEW Model: Date of Purchase: Serial Number: Sales Representative: Address: Phone Number: OVERVIEW The Compass 2 is a multi-functional cleaning machine intended for commercial use. The ™ appliance applies chemical at low pressure and uses high pressure to clean with. Then the soiled water is vacuumed back into the recovery tank. CMPS2 86305210 11/21/07 2
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS Machine Data Log/Overview.........................2 GROUP PARTS LIST Table of Contents..........................................3 Control Panel................................................5-1 Decal.............................................................5-3 HOW TO USE THIS MANUAL Solution Tank................................................5-5 Solution-Injector Assembly ...........................5-7 How to use this Manual................................
Inhaltszusammenfassung zur Seite Nr. 4
HOW TO USE THIS MANUAL The SAFETY section contains important information This manual contains the following sections: regarding hazard or unsafe practices of the machine. Levels of hazards is identified that could - HOW TO USE THIS MANUAL result in product or personal injury, or severe injury - SAFETY resulting in death. - OPERATIONS The OPERATIONS section is to familiarize the - MAINTENANCE operator with the operation and function of the - PARTS LIST machine. The HOW TO USE T
Inhaltszusammenfassung zur Seite Nr. 5
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. See Grounding Instructions. Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service. Do not allow machine to be used as
Inhaltszusammenfassung zur Seite Nr. 6
HAZARD INTENSITY LEVEL The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death. CAUTION - Hazards or unsafe practices which could result in minor person
Inhaltszusammenfassung zur Seite Nr. 7
GROUNDING INSTRUCTIONS THIS PRODUCT IS FOR COMMERCIAL USE GROUND-FAULT CIRCUIT-INTERRUPTER ONLY. PROTECTION (120V ONLY) This pressure washer is provided with a ELECTRICAL: (GFCI) built into the plug of the power supply The amp, hertz, and voltage are listed on the data cord. This device provides additional protection label found on each machine. Using voltages above from the risk of electric shock. Should or below those indicated on the data label will cause replacement of the
Inhaltszusammenfassung zur Seite Nr. 8
SAFETY LABEL LOCATION The following WARNING LABEL(S) are found on your cleaning unit. These labels point out important Warnings and Cautions which should be followed at all times. Failure to follow warnings and cautions could result in fatality, personal injury to yourself and/or others, or property damage. Follow these instructions carefully! DO NOT remove these labels. NOTE: If at any time the labels become illegible, promptly replace them. WARNING LABEL 86242230 PRV NO. 500009
Inhaltszusammenfassung zur Seite Nr. 9
TECHNICAL SPECIFICATIONS ITEM DIMENSION/CAPACITY 120V, 14A, 60HZ Electrical 230V, 7A, 50HZ Electric Pump Motor 1/2hp, 1750rpm Solution Pump 700psi (48 bars), Axial plunger 3 Electric Vacuum Motor 2stage, 1.25hp (2.80m /min.) Waterlift 82 in. (208 cm) Solution Capacity 29 gallons (111L) Recovery Capacity 19 gallons (70L) Wheels - Front (2) 6 in. dia. (15.24cm) X 1.5 - Rear (2) 12 in. dia. ( 30.48cm)X 1.75 Dimensions – Weight 205 lb. (93kg) Dimensions – Length 36 in. (91.4cm
Inhaltszusammenfassung zur Seite Nr. 10
HOW THE MACHINE WORKS The Compass 2 is a multi-functional cleaning The function of the chemical system is to ™ machine intended for commercial use. The dispense chemical into the clean water system. appliance applies chemical at low pressure and The chemical system consists of the chemical uses high pressure to clean with. Then the reservoir, chemical cap and a chemical- soiled water is vacuumed back into the metering selector. The chemical reservoir recovery tank. stores and di
Inhaltszusammenfassung zur Seite Nr. 11
COMPONENTS 9 7 1 5 11 3 6 8 2 10 4 1. Control Panel 7. Recovery Tank Lid 2. Solution Tank 8. Recovery Tank Drain Hose 3. Solution Tank Lid 9. Chemical Siphon Caps 4. Solution Tank Drain Hose 10. Electrical Cord 5. Solution Tank Fill Hose 11. High Pressure Hose Storage 6. Recovery Tank CMPS2 86305210 11/21/07 3-3
Inhaltszusammenfassung zur Seite Nr. 12
CONTROLS 4 3 9 7 8 6 5 2 1 1. Caster Lock 5. Solution Accessory Tool Hook-Up 2. Chemical Selector and Metering Valve 6. Vacuum Accessory Tool Hook-Up 3. Pump Circuit Breaker 7. Vacuum Circuit Breaker 4. Pump Switch/Pump Chemical Switch 8. Vacuum Switch 9. Main Switch (230V only) CMPS2 86305210 04/23/08 3-4
Inhaltszusammenfassung zur Seite Nr. 13
CONTROLS 1. SOLUTION ACCESSORY TOOL HOOK-UP Used for various auxiliary-cleaning tools. 2. VACUUM ACCESSORY TOOL HOOK-UP To use accessory tool, remove hose from vac shoe and attach to accessory tool adaptor. 3. VACUUM SWITCH Turns the vacuum motor On and Off. 4. PUMP SWITCH High pressure no chemical, low pressure with chemical. 5. CHEMICAL SELECTOR AND METERING VALVE Meters the amount of chemical being dispensed and selects between chemical A or B
Inhaltszusammenfassung zur Seite Nr. 14
OPERATIONS FILLING THE MACHINE NOTE:Do not put defoamer, solvents spotter or prespray chemicals in the solution tank. 3. Attach the adapter cap and intake hose to the Compass 2 Chemical bottle. Refer to the TM Compass 2 Chemical Label for the desired TM dilution. 1. Always use gloves and eye protection. Never spray solution towards people. 4. Position the Compass 2 machine in t
Inhaltszusammenfassung zur Seite Nr. 15
OPERATIONS 5. Always Spray chemical using low pressure. 7. Turn Chemical off. Pressure clean by rinsing surfaces at high pressure. 6. Use brush or grout tool for heavy soiled areas. 8. Use Squeegee or Gulper tool to remove standing water. CMPS2 86305210 11/21/07 3-7
Inhaltszusammenfassung zur Seite Nr. 16
OPERATIONS UNLOADER VALVE 9. Store and secure hoses and tools neatly. 11. From the factory your Compass 2 is set to spray at 600 psi (high pressure) and 200 psi (low pressure w/chemical injection). To lower pressure turn the unloader valve knob counter clockwise. The valve is accessed from below the machine through a hole in the bottom frame. Only turn the valve a maximum of three revolutions. Note: Lowering the pressur
Inhaltszusammenfassung zur Seite Nr. 17
OPERATIONS Care must be exercised in the use of all chemicals. Chemicals are poisonous and can pose a health risk. Read and follow manfacturers instructions regarding dangers and correct usages. The internal parts of the pump used in the machine are suitable for use with most carpet cleaning chemicals. But they are susceptible to chemical attack from some cleaning substances, such as hydrocarbon solvents and chlorinated bleaches. These non-compatible materials are no
Inhaltszusammenfassung zur Seite Nr. 18
NOTES: 3-10 CMPS2 86305210 11/21/07
Inhaltszusammenfassung zur Seite Nr. 19
MAINTENANCE 3 1 5 7 6 2 4 1. Float Shut-Off 5. Pump 2. Strainer 6. Adjustable Unloader Valve 3. Circuit Breakers 7. Injector Assembly & Coil 4. Vacuum Motor CMPS2 86305210 01/14/08 4-1
Inhaltszusammenfassung zur Seite Nr. 20
MAINTENANCE 1. FLOAT SHUT-OFF 3. CIRCUIT BREAKERS The float shut-off is located inside the Circuit breakers interrupt the flow of power recovery tank. The purpose of the float in the event of an electrical overload. When shut-off is to notify the user that the a circuit breaker is tripped, reset it by recovery tank is full. Remove daily and pressing the exposed button. If a circuit clean any debris for maximum airflow. breaker continues to trip, the cause of the electrical ov