Inhaltszusammenfassung zur Seite Nr. 1
Room Air-conditioner indoor units
Console Type
OPERATION AND INSTALLATION MANUAL
AF072XCEAA
AF092XCEAA
AF122XCEAA
AF142XCEAA
No.0010577698
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
Inhaltszusammenfassung zur Seite Nr. 2
Table of Contents Cautions 1-4 5 Parts and Functions Operation hints 6 Maintenance 7 Trouble shooting 8 Installation Manual of Room Air Conditioner 9-14
Inhaltszusammenfassung zur Seite Nr. 3
Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's information given in the User's Guide inoperative and safe. Unplug the air carefully. The User's Guide contains very conditioner in order to avoid the risk of child important observations relating to the entrapment. assembly , operation and maintenance of the air conditioner. It must be
Inhaltszusammenfassung zur Seite Nr. 4
Cautions Do not obstruct or cover the ventilation 6. The appliance is not intended for use by grille of the air conditioner. Do not put young children or infirm persons without fingers or any other things into the supervision. inlet/outlet and swing louver. 7. Young children should be supervised to ensure that they do not play with the Do not allow children to play with the air applience. conditioner. In no case should children be allowed to sit on the outdoor
Inhaltszusammenfassung zur Seite Nr. 5
Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water
Inhaltszusammenfassung zur Seite Nr. 6
Cautions Use of Air Conditioner WARNING When abnormality such as burnt-small found, immediately Use an exclusive power source with a circuit breaker. stop the operation button and contact sales shop. OFF STRICT ENFORCEMENT Do not use power supply cord Connect power supply cord to the After installed, the unit shall be extended or connected in halfway. outlet completely. tested for electric leakage. PROHIBITION STRICT STRICT ENFORCEMENT ENFORCEMENT Do not use power supply c
Inhaltszusammenfassung zur Seite Nr. 7
Parts and Functions Indoor unit 1 2 3 4 5 1.OUTLET 2.CONTROL PANEL 3.INLET 4.FILTER ( inside ) 5.OUTLET 5
Inhaltszusammenfassung zur Seite Nr. 8
Operation hints than used Power failure resume (please set and apply as necessary) With setting of power failure resume, if sudden power failure occurs, the unit will resume original operation when power is supplied again. Setting method: with ON of remote controller (except TIMER and FAN),repeatedly press SLEEP button 10 times in 5 seconds,after 4 Beep from the buzzer,the unit comes into power failure resume mode. To cancel: press SLEEP button continuously 10times in 5 seconds,the buzzer sounds
Inhaltszusammenfassung zur Seite Nr. 9
Maintenance Cleaning of the unit Turn off the power switch Do not touch with wet hand Do not clean with hot water or solvent Take off the air inlet grill First switch off the power supply,take off the screw cap,loosen the screw with cross screwdriver . Clean the filter Use water or vacuum cleaner to remove dust. If it is too dirt, clean with detergent or neutral soap water. Rinsing with fresh water, dry the filter and re-assemble. Caution: Do not wash filter in hot water above 40∞C, which wi
Inhaltszusammenfassung zur Seite Nr. 10
Trouble shooting Before asking for service, check the following first. Phenomenon Cause or check points The system does not restart When unit is stopped, it won't restart immediately until 3 minutes have elasped immediately. to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing Noise is heard: or gurgling noise may be heard. At first 2-3 minutes
Inhaltszusammenfassung zur Seite Nr. 11
more than more than Installation Manual of Room Air Conditioner Installation of indoor unit selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place ,away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evently to every corner of the room. Place near power supply socket.Leave enough space around the unit. Fig1 Place ,robust not causing vibration,where the body can be supported sufficiently. 330 To pre
Inhaltszusammenfassung zur Seite Nr. 12
Installation Manual of Room Air Conditioner Fixing of the unit Indoor side Outdoor side 1. Position of the wall hole Wall hole should be decided according to installation Wall hole Thickness of wall place and piping direction.(refer to installation drawings). 70mm 2. Making a wall hole Drill a hole of 120X70mm dia. with a little slope towards outside. (Cross section of wall hole) 3. Piping connection (1)Schematic diagram for unit connection Flared pipe connection 3-way Valve Indo
Inhaltszusammenfassung zur Seite Nr. 13
Installation Manual of Room Air Conditioner Piping connection of the indoor unit 1. Arrangement of piping and drainage pipe After opening inlet grill,you will see a control box. Remove the cover before working. Cut away, with a hammer or a saw, the lid for piping according to piping direction. Insulation material Drain hose Copper tube Connecting electric cable for indoor and outdoor unit According to the piping method, connect the piping on indoor unit with union of connection pipe. A
Inhaltszusammenfassung zur Seite Nr. 14
1(L) Installation Manual of Room Air Conditioner Electric wiring : Process of wire connections 1. Loop terminal After removing the screw, fix the wire ring on the screw, reinsert the screw into the block terminal and then tighten the screw. 2. Straight terminal After loosening the screw, inset the wire end into the block terminal and then tighten the screw. Slightly pull the wire to see if it is tightly fixed. 3. Wire capping After completion of connection, capping clips mu
Inhaltszusammenfassung zur Seite Nr. 15
Installation Manual of Room Air Conditioner Others 1.Power supply requirements: Voltage: single-phase1PH,220-230V*,50Hz Dedicated electrical cable should be installed by a qualified technician in accordance with the state regulation for electrical engineering. The power source must be grounded. A circuit breaker must be installed Electrical cables should be connected by ìYî method. Damaged or wornelectrical cable must be replaced by authorized after sales agents. The power plug should be connec
Inhaltszusammenfassung zur Seite Nr. 16
Resumable failures are marked with " ", the others are not resumable failures. Resumable failure will disappear when the failure is eliminated and its failure code will disappear automatically within 30 seconds. But the other failure code will disappear only after the unit starts up once again. When failure occurs, the unit only can receive "OFF" signal from the controller. And when the unit is shut off, the failure code will disappear. Failure description Flash times of indoor receiver board
Inhaltszusammenfassung zur Seite Nr. 17
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P.R.C Web Site: http://www.haier.com