Inhaltszusammenfassung zur Seite Nr. 1
System Controller WV-CU550C
IRIS
RESET CLOSE OPEN
1 2
3
4
5
6
7 8
9
ZOOM FOCUS
TELE
NEAR
MON
CAM
0
SLOW
WIDE
FAR
ESC
SET
ALARM
BUSY
F1
F2
F3
F4
UP
ACK FOWARD
BACK
RESET
SEQ SEQ ALT
LEFT
RIGHT
AUX
DEC INC
1 2 -1CAM +1CAM STOP
DOWN
System Controller
Operating Instructions
Model No. WV-CU550C
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
Inhaltszusammenfassung zur Seite Nr. 2
CONTENTS IMPORTANT SAFETY INSTRUCTIONS ......................................................................................................................................... 3 PREFACE ....................................................................................................................................................................................... 4 FEATURES ......................................................................................................................
Inhaltszusammenfassung zur Seite Nr. 3
IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not use near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polarize
Inhaltszusammenfassung zur Seite Nr. 4
PREFACE The WV-CU550C System Controller, when combined with the optional WJ-SX550C Matrix Switcher and WJ-AD550 Extension Unit, allows for flexible control of 128 cameras and 16 monitors. When used in a system with either Receivers (WV-RC100 or WV-RC150) or with Panasonic’s Combination cameras, the WV- CU550C can control camera functions such as zoom and focus and can also control accessory equipment such as Pan/Tilt Heads. In addition, the WV-CU550C can control sequential switching in systems p
Inhaltszusammenfassung zur Seite Nr. 5
PRECAUTIONS • Refer all work related to the installation of this • Do not use strong or abrasive detergents when product to qualified service personnel or system cleaning the appliance body. installers. Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild detergent • Do not attempt to disassemble the appliance. and wipe gently. To prevent electric shock, do not remove screws or covers. • Do not operate the appliance beyond its specified There are n
Inhaltszusammenfassung zur Seite Nr. 6
4 3 2 1 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS Front View q w e r t ALARM BUSY F1 F2 F3 F4 !8 UP !9 ACK BACK FORWARD IRIS RESET SEQ SEQ ALT PRESET CLOSE OPEN 1 2 3 LEFT RIGHT y @1 4 5 6 AF @0 AUX DEC INC ZOOM FOCUS 7 8 9 DOWN 12 –1CAM +1CAM STOP TELE NEAR MON CAM 0 WIDE FAR SLOW ESC SET System Controller WV-CU550C !7 !6 !5 !4 !3 !2 !1 !0 o i u Rear View DATA CONTROLLER CONTROLLER IN OUT UNIT NO. MODE 1-8 TERM 0 ON OFF ON OFF #1 #2 #3 #4 #5 #6 6 9 8 7 6 5
Inhaltszusammenfassung zur Seite Nr. 7
q Alarm Indicator (ALARM) !1 Camera (Set) Key [CAM (SET)] Blinks to indicate that an alarm condition exists. CAM: Used for camera selection. To select a camera, It changes to steady light when the alarm is reset auto- enter the desired camera number with the Numeric matically. keys, and then press the CAM key. To turn the indicator off, press the ACK RESET button. SET: This key, in combination with the Numeric keys, is w Busy Indicator (BUSY) used to enter numeric input, such as operator ID Ligh
Inhaltszusammenfassung zur Seite Nr. 8
!7 Auxiliary Button (AUX 1,2) #4 Mode Selection Switch (MODE) These buttons toggle the auxiliary switches in the These switches are used to set the mode of the System Receiver on and off. Controller connected to the Matrix Switcher. Set the The auxiliary switches can be used, for example, to switches as shown below. activate equipment connected to the receiver, such as lamps and buzzers. MODE !8 Alternate Button (ALT) Normal Mode This button activates the alternate function of dual-func- ON12 3
Inhaltszusammenfassung zur Seite Nr. 9
INSTALLATION The installation described below should be made by qualified service personnel or system installers and should conform to all local codes. Replacing the Side Panels with the optional WV-Q62 Rack Mounting Brackets 1. Remove both the left and right side panels of the System Controller by removing four screws. 2. Remove the Palm-rest located on the front of the System Controller by removing two screws. 3. Place the Rack Mounting Brackets on both sides of the System Controller and tig
Inhaltszusammenfassung zur Seite Nr. 10
SYSTEM INFORMATION Please note that the following functions were added to Version Information improve the operation of the combination cameras. WJ-SX550 Series Matrix Switcher The onscreen display indicates the version in “Cold Start” or “Normal Start” during the power up procedure. Additions Matrix Switcher Selection of Pan/Tilt Speed The Pan/Tilt speed can be changed by selecting a mode in Model WJ-SX550B the menu (A1) displayed on the LCD display of the con- "Normal Start" troller. C
Inhaltszusammenfassung zur Seite Nr. 11
SPECIFICATIONS Power Supply: 120 V, AC 60 Hz Power Consumption: Approx. 4 W Data Input/Output: 6-conductor Modular Jack (RS-485, 4-wire) Switching Functions: Program Sequence/Tour Sequence Group Sequence/Backward Sequence Forward Sequence/Inc Dec Camera Functions: Electronic Shutter: On/Off, Shutter Speed Select Electronic Sensitivity Up Mode Select: Auto/Manual/Off Electronic Zoom: On/Off, Zoom Position: Area Select Back Light Compensation: Auto/Preset/Off Lens Functions: Iris: Open/Close/Prese
Inhaltszusammenfassung zur Seite Nr. 12
Panasonic Security and Digital Imaging Company Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, A Division of Matsushita Electric Corporation of America Ontario, L4W 2T3 Canada (905)624-5010 Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Panasonic Sales Company Regional Offices: Division of Matsushita Electricof Puerto Rico Inc. Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Ave. 65 de Infanteria. Km. 9.5 Southern: 1225 Northbrook Parkway, Suite 1-160,