Inhaltszusammenfassung zur Seite Nr. 1
RCT-MLT-II Remote Control Kits
- Installation and Operating Instructions -
INTRODUCTION FCC REQUIREMENTS
The remote control system can be operated thermostati-
WARNING: CHANGES OR MODIFICATIONS TO
cally or manually from the transmitter. The system oper-
THIS UNIT NOT EXPRESSLY APPROVED BY
ates on radio frequencies (RF) within a 20 foot range. Can
THE PARTY RESPONSIBLE FOR COMPLIANCE
be used with DSI, IPI or Standing Pilot systems.
COULD VOID THE USER’S AUTHORITY TO OPER-
This remote control
Inhaltszusammenfassung zur Seite Nr. 2
TP TH TP TH Wire Colors INSTALLATION INSTRUCTIONS • Gas Valve - Millivolt or Installing Electrical Service to the Junction Box Electronic Ignition .............................................. Red WARNING: TURN ELECTRICAL POWER OFF AT • Fan/Blower - 110 VAC .........................Plug from Fan THE CIRCUIT BREAKER BEFORE BEGINNING • Flame Controller - HI/LO solenoid ..................Orange THIS INSTALLATION. RECEIVER WIRING INSTRUCTIONS NOTE: Some appliances do not have a cover plate.
Inhaltszusammenfassung zur Seite Nr. 3
GAS CONTROL KNOB VALVE SCREW NUT WASHER VARIABLE REGULATOR WASHER VARIABLE SOLENOID REGULATOR VARIABLE JAM NUT FLAME CONTROL REGULATOR PLUNGER SOLENOID Figure 4. 3. Plug the remote receiver into the 110/120 VAC power NOTE: All steps required for installation of the supply. fl ame controller MUST be done by a qualifi ed gas 4. Light the fi replace as directed in the Owner’s Manual. service technician. 5. Set the manifold pressure on the gas valve by rotating the fl ame control solenoid. Adjust un
Inhaltszusammenfassung zur Seite Nr. 4
The remote receiver has a 3-position slide switch: OFF/ TRANSMITTER REMOTE/ON (see Figure 6). Important: Before operating remote control, transmit- ter and receiver must have matching security codes. (Receptacle on back) See section ‘Matching Security Codes’. LEARN 110/120 VAC, 3A Important: Review ‘Thermo-Updating/Communication- Safety Features’ under ‘Transmitter Safety Features’ section. Communication Safety features shut down the REMOTE RECEIVER Line cord fi replace system when a potential
Inhaltszusammenfassung zur Seite Nr. 5
1. LOW - Battery power low. Replace batteries within two weeks. 2. TIMER - Indicates time remaining before system shuts off, when timer-programmed, 9 - hour maximum setting. 3. MODE - Indicates operation MODE of system. ON indicates the system is on, either manually or thermostatically. THERMO indicates the system will automatically cycle ON/OFF, depending on programmed SET temperature. OFF indicates the entire system is turned off. 4. SET - Indicates desired SET room temperature for THERMO
Inhaltszusammenfassung zur Seite Nr. 6
NOTE: To prevent repeated thermo-cycling of the gas appliance, the sensing unit in the transmitter will only ac- tivate the remote receiver when the temperature change exceeds 2º F (1º C) above or below the SET (desired) temperature. When the transmitter is in the THERMO mode, it should be kept away from direct sources of heat such as fi re- places, incandescent lighting and direct sunlight. Leaving the transmitter in direct sunlight, for example, will cause it to read the room temperature
Inhaltszusammenfassung zur Seite Nr. 7
Adjusting the Flame Height - Should the receiver NOT receive a transmitter signal every 15 minutes (COMMUNICATION-SAFETY fea- Operates in ON or THERMO mode ture), the RECEIVER will begin a 2 HOUR (120 minute) This remote control system allows the user to control countdown timing function. If during this 2 hour period, the height of the FLAME when the gas valve is factory the receiver does not receive a signal from the transmit- equipped with a FLAME CONTROLLER. ter, the RECEIVER will shut d
Inhaltszusammenfassung zur Seite Nr. 8
6. Advance the SET temperature on the transmitter to a Timer Operation temperature of at least 2º F (1º C) above the ROOM The countdown timer will operate in either the manual ON temperature displayed on the LCD screen and the or THERMO mode. Once the fi replace system is in an system fl ame will ignite. operating mode, set the countdown timer to turn off in 15 7. Set the SET temperature to at least 2º F (1º C) below minutes. The timer function will allow operation to continue the room tempe
Inhaltszusammenfassung zur Seite Nr. 9
NEUTRAL HOT IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR I S TRANSFORMER WHITE 3VAC ORANGE GROUND TO FIREPLACE PLUG IN CHASSIS JUMPER WIRE BATTERY PACK (TO BROWN) THERMOSTAT WIRE ASSEMBLY VALVE Figure 9. Intermittent Pilot Ignition (IPI) Wiring Diagram PIEZO PILOT THERMOSTAT WIRE ASSEMBLY THERMOCOUPLE RED VALVE Figure 10. Standing Pilot Ignition Wiring Diagram 9 RED WHITE ORANGE GREEN
Inhaltszusammenfassung zur Seite Nr. 10
INTERMITTENT IGNITION MODULE PILOT I PLUG-IN 3VAC IGNITOR 3V TRANSFORMER ON/OFF S WALL SWITCH FLAME SPARKER/ SENSOR IGNITION MODULE (3V) WHT ORG VALVE LOW VOLTAGE GROUND TO SEE NOTE 1 FIREPLACE CHASSIS GROUND REMOTE CONTROL HOT NEUTRAL WHITE WIRE CAN BE PLUGGED INTO ANY OF #1-#5 BLACK WIRE CAN BE LOCATIONS PLUGGED INTO ANY OF PIGGYBACK ON THE #1 - #5 LOCATIONS ON/OFF SWITCH NEUTRAL SIDE ON THE HOT SIDE TRANSFORMER 3VAC PLUG IN VALVE Figure 11. Intermittent Pilot Ignition (IPI) Wiring Diagram BL
Inhaltszusammenfassung zur Seite Nr. 11
Remote Control Wiring Diagrams IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR I REMOTE RECEIVER S TRANSFORMER WHITE 3 VAC ORANGE GROUND TO FIREPLACE PLUG IN CHASSIS JUMPER WIRE (TO BROWN) BATTERY PACK VALVE Figure 13. Remote Control Intermittent Pilot Ignition (IPI) Wiring Diagram PILOT PIEZO THERMOCOUPLE RED VALVE REMOTE RECEIVER Figure 14. Remote Control Standing Pilot Ignition Wiring Diagram 11 BLACK RED WHITE ORANGE GREEN