Product Specifi cations WM
Weight Capacity 79 kg (175 lbs)
Mounting Options Verical Mount:
Wall plate attaches to vertical wall
surfaces. Includes fasteners for wood
(16” or 24” centered studs) or concrete
wall mounting. For mounting to metal
studs or other surfaces, customer must
supply fasteners.
Standards Monitor Attachment:
Attaches to mo
Inhaltszusammenfassung zur Seite Nr. 2
AB C 1x 1x 1 4x 4x 4x LONG SPACER A M4x20mm 2 4x 4x M4x40mm M8x80mm LONG SPACER B 4x 4x M5x20mm 4x SHORT SPACER A 4x 4x 3 M5x40mm SHORT SPACER B 4x 8x M6x20mm WASHER A 4x 4x 4x M6x45mm 4 WASHER B 4x 2x M8x25mm PENTA SCREW 1x 2x 4x 5 TOOL PENTA LOCKING SCREW M8x50mm Ø 3/16" (5 mm) Ø 3/8" (10 mm) Wood Concrete Stud Finder 13mm 888-60-182P-01 rev.D 01/07 2 of 22 1 2
Inhaltszusammenfassung zur Seite Nr. 3
Components: Display Brackets Rail Fasteners CAUTION: A stable, safe installation depends on using the correct combination of fasteners, and while Ergotron tries to provide fasteners to accommo- date most large displays, with new displays always entering the market, it is possible that your display may require special fasteners that were not included with this product. If you believe your display requires special fasteners and you need help d
Inhaltszusammenfassung zur Seite Nr. 4
1 a b Ø TOP c 888-60-182P-01 rev.D 01/07 4 of 22
Inhaltszusammenfassung zur Seite Nr. 5
If a stand is already attached to * * * your display, remove it according to display manufacturer directions. Place the display on a clean, fl at, padded surface or, if you prefer, lean the displ ay against a stable, vertical surface. 1 1 1 Choosing Display Bracket Fasteners Notice that several sizes of screws and spacers have been provided for mounting the Tilt Mount brackets to your large display. The instructions and illustrations in this Reference Guide will help
Inhaltszusammenfassung zur Seite Nr. 6
a bc 2 3 888-60-182P-01 rev.D 01/07 6 of 22
Inhaltszusammenfassung zur Seite Nr. 7
2 2 2 Compare this measurement Compare this measurement to the recommended screw (based on display back type and diameter), taking into consideration the need for a minimum amount of thread engagement (the minimum thread engagement is the same as the diameter of the screw, for instance, the minimum thread engage- ment for an 8mm diameter screw is 8mm). If the screw is longer than your display’s mounting hole depth, you will need to compensate by using one of the provide
Inhaltszusammenfassung zur Seite Nr. 8
4 TOP MINIMUM THREAD ENGAGEMENT 888-60-182P-01 rev.D 01/07 8 of 22
Inhaltszusammenfassung zur Seite Nr. 9
4 4 4 ATTACH BRACKETS TO DISPLAY a Place Display Brackets (with pre-de- a termined fasteners) on back of display: a (y) The display brackets (y) should be centered verti- cally on the back of the dis- play - the distance between (y) the top of the bracket (y1) and the top of the display (y1) should be the same as the distance between the bot- tom of the bracket (y2) and (y1) the bottom of the display. (y2) (y2) (x) The display brackets should be mounted to th
Inhaltszusammenfassung zur Seite Nr. 10
WOOD CONCRETE 5 Ø 3/8" (10 mm) Ø 3/16" (5 mm) 12 14 Mounting to structures other than those specifi ed has not been evaluated by UL. 888-60-182P-01 rev.D 01/07 10 of 22
Inhaltszusammenfassung zur Seite Nr. 11
5 5 5 WALL PLATE MOUNTING INSTRUCTIONS Ergotron provides fasteners for mount- ing the Wall Mount to the following wall confi gurations: Wall Type I - Solid Wood Studs (2”x4”) 16” or 24” (406mm / 610mm) on center. Wall Type II - Solid Concrete (3000 psi) - requires minimum material thickness of 4” (102mm); if concrete is covered with a layer of drywall, plaster or similar material, maximum allowed thickness of covering is 5/8”(16mm). If mounting to wall con
Inhaltszusammenfassung zur Seite Nr. 12
WOOD a b 6 c d Ø 3/16" (5 mm) 16 888-60-182P-01 rev.D 01/07 12 of 22
Inhaltszusammenfassung zur Seite Nr. 13
6 6 6 ATTACH RAIL TO WALL Solid Wood Studs WARNING: Ensure that the wall structure is capable of supporting four times the total weight of mounted equipment. Mounting to wall surfaces that do not meet this criteria may result in an unstable, unsafe condition which could lead to personal injury and/or property damage. Consult a construction professional if you * have any doubt about what this means in regard to your particu- lar application. * Before proceeding w
Inhaltszusammenfassung zur Seite Nr. 14
CONCRETE a 6 b c 3-1/8" (80 mm) Ø 3/8" (10 mm) d 2x 16 888-60-182P-01 rev.D 01/07 14 of 22
Inhaltszusammenfassung zur Seite Nr. 15
6 6 6 ATTACH RAIL TO WALL Solid Concrete Before proceeding with this * * * installation, consult the manufac- turer of your display for recommen- dations on choosing a mounting location that will ensure optimum performance. Location consider- ations might include: mounting height - based on size of display, viewing angle - based on room di- mensions, access to power outlets, cable connections for speakers/ac- cessories, protection from light, a heat and vibration,
Inhaltszusammenfassung zur Seite Nr. 16
7 a 4x 4x b 888-60-182P-01 rev.D 01/07 16 of 22
Inhaltszusammenfassung zur Seite Nr. 17
7 7 7 a Hold Rail against wall and start a a screws with washers. b Tighten screws with 13mm socket b head (power tool is recommended) b in the following sequence: 1st-lower right; 2nd-upper left; 3rd-lower left; 4th-upper right. DO NOT OVERTIGHTEN SCREWS! For solid concrete applications, torque screws to 60 in-lbs (6.8 N m). Screws must be fully seated in order to support applied load! The minimum torque for screws in solid wood studs is 60
Inhaltszusammenfassung zur Seite Nr. 18
8 Center of Display and Center of Studs Aligned - ALLOWED a Center of Display Located Over Center of Stud - ALLOWED b Center of Display Located Past Center of Stud - NOT ALLOWED 888-60-182P-01 rev.D 01/07 18 of 22
Inhaltszusammenfassung zur Seite Nr. 19
8 8 8 HANG DISPLAY ON RAIL a Hang the display on the rail, a a positioning it so that the center of the display is aligned between the studs (indicated by tape strips). If necessary, the display can be positioned off cen- ter as long as the center of the display doesn not extend beyond the center of either stud - see illustration! b b Once the display is in a suitable position along the rail, push forward b at the bottom of the display bracket assembly, to
Inhaltszusammenfassung zur Seite Nr. 20
9 ab 2x 2x LOCKING SCREW SECURITY SCREW 9 9 9 At the bottom of each of the display brackets, install and tighten either a Security Screws with Pentagon tool* a a b Locking Screws with Phillips screw- b driver b The Pentagon tool has a special fi ve- * sided tip designed to deter theft - keep * * it in a safe place so that is available whenever needed. 888-60-182P-01 rev.D 01/07 20 of 22