SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-12CR03-Y
HSU-18CR03-Y
Please read this operation manual before using the air conditioner.
0010515222
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
Cautions Safety Instructions and Warnings Disposal of the old air conditioner Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully. The User's Guide contains very impor- in order to avoid the risk of child entrapment. tant observations relating to the assembly, operation and maintenance of the air It must be noticed that
Inhaltszusammenfassung zur Seite Nr. 4
Cautions 7. The appliance is not intended for use Do not obstruct or cover the ventilation by young children or infirm persons grille of the air conditoner.Do not put fingers without supervision. or any other things into the inlet/outlet and swing louver. 8. Young children should be supervised to ensure that they do not play with Do not allow children to play with the air the applience. conditioner.In no case should children be allowed to sit on the outdoor unit. 9.Please
Inhaltszusammenfassung zur Seite Nr. 5
Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water
Inhaltszusammenfassung zur Seite Nr. 6
Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT OFF ENFORCEMENT Connect power supply cord Use the proper voltage Do not use power supply cord to the outlet completely extended or connected in halfway STRICT STRICT PROHIBITION ENFORCEMENT ENFORCEMENT Take care not to damage Do not insert objects into the air Do not use power supply cord the power supply cord. in
Inhaltszusammenfassung zur Seite Nr. 7
Parts and Functions Indoor unit air ionization purify layer Outlet (inside) Inlet Air filter(inside) Vitamin C layer+ Bacteria-killing medium sets Inlet grille (inside) display board(inside) Horizontal flap Anion generator (inside) (adjust up and down air flow Don't adjust it manually) Vertical blade(inside) (adjust left and right air flow) Power plug Outdoor unit 1 3 OUTLET CONNECTING PIPING AND ELECTRICAL WIRING 2 4 INLET DRAIN HOSE 5
Inhaltszusammenfassung zur Seite Nr. 8
Parts and Functions 33 34 16 11 15 22 21 17 19 10. ON/OFF button Used for unit start and stop. 11. TIMER ON display 12. FAN SPEED display LOW MED HI AUTO 13. LOCK display PURIFY 14. SWING UP/DOWN display 15. SLEEP display 16. HEALTH display FRESH 28 17. Operation mode display Operation mode AUTO COOL DRY FAN POWER/SOFT Remote controller Display board 18.Singal sending display 19. POWER/SOFT display 20. Left/right air flow display 21. TEMP display Remote controller: to display the TEMP. setting
Inhaltszusammenfassung zur Seite Nr. 9
Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: FRESH 1. Press CLOCK button,"AM" or "PM" flashes. 2. Press or to set correct time. Each press will increase or decrease POWER/SOFT 1 min. If the button is kept depressed, time will change quickly. 3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working. Remote controller's operati
Inhaltszusammenfassung zur Seite Nr. 10
Operation HEALTH operation Display board 1.Unit start Press ON/OFF on the remote controller, unit starts. Remote controller 2.Health anion function Press Purify button. is displayed on the remote controller and is displayed on the display board . Air conditioner starts air ionization purify and health anion function operation. For twice press, and disappear,the operation stops. When indoor fan motor is running, it has air ionization purify and healthy process function.
Inhaltszusammenfassung zur Seite Nr. 11
Operation Auto Operation Display board 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select Auto operation 3.Select temp.setting PURIFY Press TEMP. button Every time the button is pressed, temp.setting FRESH increase 1oC,if kept depressed, it will increase rapidly Every time the button is pressed, temp.setting POWER/SOFT de
Inhaltszusammenfassung zur Seite Nr. 12
Operation Cool Operation Display board 1. Unit start Press ON/OFF on the remote controller, unit starts. Remote controller 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select COOL operation 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting PURIFY increase 1oC, if kept depressed, it will increase rapidly FRESH Every time the button is pressed, temp.setting decrease 1oC
Inhaltszusammenfassung zur Seite Nr. 13
Operation Dry Operation Display board 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select DRY operation PURIFY 3.Select temp.setting Press TEMP. button FRESH Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly POWER/SOFT Every time the button is pressed, temp.setting decr
Inhaltszusammenfassung zur Seite Nr. 14
Operation Fan Operation Display board 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN Then Select FAN operation PURIFY 3.Fan speed selection Press FAN button. For each press, fan speed changes as FRESH follows: Remote controller: POWER/SOFT LOW MED HI 4.Unit stop Press ON/OFF button, the unit stops. About FAN operation In FAN opera
Inhaltszusammenfassung zur Seite Nr. 15
Operation Air Flow Direction Adjustment 1.Status display of air sending Horizontal flap Vertical blade Pos.1 Pos.1 Pos.2 Pos.2 PURIFY Pos.3 Pos.3 FRESH Pos.4 Pos.4 POWER/SOFT Pos.5 Pos.5 Pos.6 Pos.6 (Auto swing) Pos.7 Pos.8 2.Up and down air flow direction For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN Pos.1 Pos.2 Pos.3 Pos.4 Pos.6 remote controller: AUTO: Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 remote contro
Inhaltszusammenfassung zur Seite Nr. 16
Operation Sleep Operation Display board Operation Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP SLEEP operation starts SLEEP operation stops mode and bring you a sound sleep. Approx.6hrs Use of SLEEP function O Rises 1 C 1 hr After the unit starts, set the operation status, O then press SLEEP button before which the Rises 1 C 1 hr clock must be adjusted and time being set. Unit stop Temp.setting Operation Mode In COOL, DRY mode 1. In COOL,DRY mode 1
Inhaltszusammenfassung zur Seite Nr. 17
Operation Timer On/Off Operation Display board Set clock correctly before starting TIMER operation. Remote Controller 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "w
Inhaltszusammenfassung zur Seite Nr. 18
Operation Timer On-Off Operation Display board Set clock correctly before starting Remote Controller TIMER operation. 1. After unit starts, select your desired operation mode . Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON - OFF). " "will flash. 3.
Inhaltszusammenfassung zur Seite Nr. 19
POWER/SOFT Operation Operation POWER Operation Remote controller When you need rapid cooling, you can use this function. Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed, display changes as follows: BLANK POWER SOFT Stop the display at In POWER operation status: FRESH In COOL mode, compressor runs in high frequency for 15 min then returns to original status setting. To cancel POWER operation Press POWER/SOFT button twice ,POWER/SOFT disappears. SOFT Operati
Inhaltszusammenfassung zur Seite Nr. 20
Operation Health airflow Operation 1.Press ON/OFF to starting Remote controller The liquid crystal will display the working state of last time (Except timer, sleeping, power/soft and health airflow). Setting the comfort work conditions. 2.The setting of health airflow function 1).Press the button of health airflow, appears on the display. The nether inlet and outlet grills of the air condit- ioner are closed and the airflow is blown horizontally from the above inlet and outlet grills. Avo