Inhaltszusammenfassung zur Seite Nr. 1
Dynamix HP-51M User Manual EN-V1.00
Dynamix HP-51M
Dynamix HP-51M
HomePNA3.1 Coax MDU Master Bridge
User’s Guide
User’s Guide
Version 1.0
Jul. 2008
Inhaltszusammenfassung zur Seite Nr. 2
S TATEMENT TATEMENT S This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
Inhaltszusammenfassung zur Seite Nr. 3
Dynamix HP-51M User Manual EN-V1.00 TA AB BL LE E O OF F C O ON NT TE EN NT TS S T C INTRODUCTION __________________________________________________________ 1
INTRODUCTION Features _________________________________________________________________________ 1
Glossary _________________________________________________________________________ 1
INSTALLATION ___________________________________________________________ 2
INSTALLATION Packing List ________________________________________
Inhaltszusammenfassung zur Seite Nr. 4
Allowed Source _______________________________________________________________________ 20
Telnet/Http/Snmp Setup _______________________________________________________________ 21
System Log _____________________________________________________________________________ 22
System Time ____________________________________________________________________________ 22
Static MAC _____________________________________________________________________________ 23
Reboot System__________________________
Inhaltszusammenfassung zur Seite Nr. 5
Dynamix HP-51M User Manual EN-V1.00 swqosrate____________________________________________________________________________ 38
swqostc _____________________________________________________________________________ 38
swsmac _____________________________________________________________________________ 38
swtagvlan ____________________________________________________________________________ 39
tftp __________________________________________________________________________________ 39
time
Inhaltszusammenfassung zur Seite Nr. 6
Inhaltszusammenfassung zur Seite Nr. 7
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 1 INTRODUCTION INTRODUCTION This chapter describes the features of your HomePNA3.1 over Coax to Ethernet Master (Management) Bridge -- HP-51M. Refer to “HomePNA3.1 over Coax” as HCNA from this point. Features ♦ One HCNA Port for Driving HomePNA3.1 Signal into Existing Coaxial Cable ♦ One TV/Antenna Port for TV Set Connection or for TV Signal from VHF/UHF Antenna/CATV ♦ Two Fast Ethernet Port with Auto-Detect MDIX Function(Auto Crosso
Inhaltszusammenfassung zur Seite Nr. 8
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 2 INSTALLATION INSTALLATION This chapter describes the installation procedure for your bridge. Packing List Your package should come with the equipment listed below, ♦ One Main Unit (HCNA to Ethernet Master Bridge) HP-51M ♦ One DC 5V Power Adaptor ♦ One F-Type Coaxial Cable (RG-59U) ♦ One RJ-45 Ethernet Cable (CAT-5) Rear Panel Figure 1: Rear Panel of HP-51M Connectors 1. DC5V: Connect to the power adapter plug. 2. LAN
Inhaltszusammenfassung zur Seite Nr. 9
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Connecting the Cables To establish a new coax networking system by HP-51M, reroute the CATV/Antenna signal source over coax toward HP-51M ‘TV/Antenna’ port and connect HP-51M ‘HCNA’ port to the original coax entrance to building. HP-51M works as a Combiner for TV and HCNA signal. In each Dwelling Unit, use the HCNA EP to extract the TV signal and Ethernet packets. See Figure 2 for the detail cabling in one MDU, HP-51S Satellite/CAT V
Inhaltszusammenfassung zur Seite Nr. 10
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide You can also use other Combiner or Mixer-Splitter with HP-51M to build the same system, see the following Figure 3 for different cabling, Satellite/CATV VHF/UHF Mixer Combiner EP HP-51M Splitter M/C Optical Fiber ISP Figure 3: Different Cabling of HP-51M NOTE: After power up HP-51M, the led ‘SynMode’ will always be glowing, and led ‘Link/Act’ will light up for at least one EP is detected on the HCNA network. A dimmed led ‘Lin
Inhaltszusammenfassung zur Seite Nr. 11
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 3 CONFIGURATION CONFIGURATION This chapter describes the configuration procedure for your bridge. Configuration Methods To access and configure your bridge, choose one of the following methods: ♦ Use Web Browser ♦ Use Telnet Program ♦ Use SNMP Manager or MIB Browser Use Web Browser Web browser is the easiest tool to configure the bridge. The factory default IP address of HP-51M is ‘192.168.1.1’ and the default subnet mask is
Inhaltszusammenfassung zur Seite Nr. 12
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide System Setup (TCP/IP Properties) The main window contains the left sub-window for the items to be configured, and the right sub-window displays the contents for the selected item. Click your mouse on the item in the left window will pop out the corresponding item-window in the right side. Click on the ‘Apply’ button (or ‘OK’ button in some screens) will submit your new setting into the bridge and will take effect immediately. System As
Inhaltszusammenfassung zur Seite Nr. 13
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide manage other connected Slave EPs. The HCNA MAC exists only in HCNA (coax) domain, and is unaware for any EP end-user. System manager use system IP address and Ethernet MAC address to access HP-51M. Each HP-51M device should be stamped with both Ethernet MAC and HCNA MAC for identification. Figure 4: EP Management Architecture Firmware/Driver Files HP-51M flash ROM is capable of storing the following files: 1. System bootcode (OS bootl
Inhaltszusammenfassung zur Seite Nr. 14
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Each row represents for one EP, here we have one Master (Local) HCNA device (on the top) and 7 extra Slave EP devices shown on the window. The first two are EPs based on 3010, follows three Smart EPs based on 3110 (or called Configurable EPs), and the last two EPs that are powered off. Smart EP Denote an EP whose Ethernet properties are configurable. Based on 3110 chipset, with built-in simple management function, its Ethernet settings
Inhaltszusammenfassung zur Seite Nr. 15
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Config : configure Master’s/Smart EP’s both HomePNA and Ethernet properties or EP’s sole HomePNA properties. Del : Delete the off-line EP’s profile, to save the EP properties profile space of HP-51M. Test : run the built-in diagnostic functions. Refer “Diagnosis” for more details. Click on each device’s ‘HPNA’ button can open the window to configure its HomePNA properties. Click on ‘Ether’ button to configure its Ethern
Inhaltszusammenfassung zur Seite Nr. 16
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide HCNA driver with the new values (replace the running working values with the new setting ones) before any connected EP can access the network controlled by HP-51M. Privacy Mode Usage Example For example, first activate the ‘Privacy Mode’ by apply the ‘ON’ setting and change the ‘Privacy Key’ to ‘0x1234’. HP-51M will request to upgrade the Master’s HCNA driver, and all allowable EP’s HCNA driver. Click the ‘Apply’ button will change the
Inhaltszusammenfassung zur Seite Nr. 17
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Here we have one banned EP shown in red background after upgrade, Then power on the 2 extra off-line EPs, they will also be banned since their ‘Privacy Mode/Key’ (as default ‘OFF’/‘0x0’) doesn’t match with the Master’s (now key is ‘ON’/‘0x1234’ ). 11
Inhaltszusammenfassung zur Seite Nr. 18
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide EPs are classified by the shown background color, green for allowed EP, red for banned EP. Privacy Mode/Key Summary EP can’t communicate with each other regardless of the settings of ‘Privacy Mode’ and ‘Privacy Key’. EP could access the coax network controlled by HP-51M only if EP has the right ‘Privacy Mode’ and ‘Privacy Key’. Please refer the following diagram for more details, Master Privacy Mode On Off EP Pr
Inhaltszusammenfassung zur Seite Nr. 19
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Yellow: For Master, it has inconsistent ‘Privacy Mode/Key’ settings. You may upgrade the Master’s driver to synchronize its working values. (to replace the running working values with the setting ones). Red: For banned EP, either ‘Privacy Mode/Key’ in EP is not matched or the ‘Host Limit’ value in EP is 0. HP- 51M will refuse to serve this EP. EP HomePNA Properties (HPNA) EP (either Smart or not) conforms to the following HomePNA set
Inhaltszusammenfassung zur Seite Nr. 20
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Service and Speed/Duplex Change ‘Service’ to enable or disable the port. This setting open or close the related Ethernet switch port in EP. Default setting in field ‘Speed/Duplex’ is ‘Auto’ states for auto-negotiation. Bandwidth Control Consider port HCNA as the network backbone and refer the following diagram to set up bandwidth control parameters in EP’s Ethernet switch (Regards as Hardware bandwidth control, works for both upstrea