Inhaltszusammenfassung zur Seite Nr. 1
Advanced Hybrid System
Installation Manual
KX-TES824
Model KX-TEM824
Thank you for purchasing a Panasonic Advanced Hybrid System.
Please read this manual carefully before using this product and save this manual for future use.
Inhaltszusammenfassung zur Seite Nr. 2
System Components System Components Table Model Description Main Unit KX-TES824 Advanced Hybrid System: 3 to 8 Outside (CO) Lines, 8 to 24 Extensions KX-TEM824 Advanced Hybrid System: 6 to 8 Outside (CO) Lines, 16 to 24 Extensions Optional Service Cards KX-TE82461 4-Port Doorphone Card KX-TE82474 8-Port SLT Extension Card KX-TE82480 2-Port Analogue CO Line and 8-Port SLT Extension Card KX-TE82483 3-Port Analogue CO Line and 8-Port Hybrid Extension Card KX-TE82491 Message Expansion Card for DIS
Inhaltszusammenfassung zur Seite Nr. 3
Abbreviations in this manual Proprietary Telephone: PT Single Line Telephone: SLT Direct Station Selection: DSS Compatible Proprietary Telephones KX-T7700, KX-T7300, and KX-T7000 series PTs KX-T7710 SLT KX-T7740, KX-T7340, and KX-T7040 DSS Consoles For the equipment that can be connected to the PBX, refer to "1.2.2 System Connection Diagram". Notice Certain models may not be available in your country/area. Certain optional service cards, PTs, and features may not be available in you
Inhaltszusammenfassung zur Seite Nr. 4
Important Safety Instructions When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Read and understand all instructions. 2. Follow all warnings and instructions marked on the product. 3. Unplug the product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Clean with a damp cloth. 4. Do not use this product near water, for example,
Inhaltszusammenfassung zur Seite Nr. 5
Precautions Keep the unit away from heating appliances and devices that generate electrical noise such as fluorescent lamps, motors and televisions. These noise sources can interfere with the performance of the PBX. ˚C This unit should be kept free of dust, moisture, high temperature (more than 40 ) and vibration, and should not be exposed to direct sunlight. If you are having problems making calls to outside destinations, follow this procedure to test the outside (CO) lines: 1. Discon
Inhaltszusammenfassung zur Seite Nr. 6
Notes When disposing of any of the above products, all batteries must be removed. Follow the applicable laws, regulations, and guidelines in your country/area regarding disposal of batteries. When replacing a battery, use only the same battery type, or an equivalent recommended by the battery manufacturer. Notice Regarding removing or replacing a battery in the circuit board, consult your dealer. For users in Finland, Norway and Sweden only This unit may only be installed in a room or
Inhaltszusammenfassung zur Seite Nr. 7
Note The serial number of this product can be found on the label affixed to the unit. You should record the model number and the serial number of this unit as a permanent record of your purchase to aid in identification in the event of theft. MODEL NO. SERIAL NO. DATE OF PURCHASE NAME OF DEALER DEALER'S ADDRESS DEALER'S TEL. NO. The KX-TES824E, the KX-TES824NE, the KX-TES824GR, the KX-TES824CE/ KX-TEM824CE, and the KX-TES824PD/KX-TEM824PD are designed to interwork with the Analogue Public
Inhaltszusammenfassung zur Seite Nr. 8
Introduction About the Installation Manual This Installation Manual is designed to serve as an overall technical reference for Panasonic Advanced Hybrid System, KX-TES824 and KX-TEM824. It explains how to install the hardware and programme this PBX using KX-TE Maintenance Console. The Installation Manual is divided into the following sections: Section 1 System Outline Provides general information on the PBX, including the system capacity and specifications. Section 2 Installation Provides deta
Inhaltszusammenfassung zur Seite Nr. 9
Precautions for Users in the United Kingdom FOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY. This appliance is supplied with a moulded three-pin mains plug for your safety and convenience. A 5 amp fuse is fitted in this plug. Should the fuse need to be replaced, please ensure that the replacement fuse has a rating of 5 amps and that it is approved by ASTA or BSI to BS1362. Check for the ASTA mark or the BSI mark on the body of the fuse. If the plug contains a removable fuse cove
Inhaltszusammenfassung zur Seite Nr. 10
How to replace the fuse: Open the fuse compartment with a screwdriver and replace the fuse and fuse cover. The equipment must be connected to direct extension lines, and a payphone should not be connected as an extension. 999 and 112 can be dialled on the apparatus after accessing the Exchange line for the purpose of making outgoing calls to the BT emergency services. During dialling, this apparatus may tinkle the bells of other telephones using the same line. This is not a fault and w
Inhaltszusammenfassung zur Seite Nr. 11
Table of Contents 1 System Outline......................................................................................13 1.1 System Highlights .......................................................................................................... 14 1.1.1 System Highlights............................................................................................................. 14 1.2 Basic System Construction................................................................................
Inhaltszusammenfassung zur Seite Nr. 12
3 Guide for KX-TE Maintenance Console..............................................71 3.1 Installing KX-TE Maintenance Console.........................................................................72 3.1.1 Installing KX-TE Maintenance Console on a PC...............................................................72 3.2 Connection ......................................................................................................................74 3.2.1 Connection..............................
Inhaltszusammenfassung zur Seite Nr. 13
Section 1 System Outline This section provides general information on the Advanced Hybrid System, including system capacity and specifications. Installation Manual 13
Inhaltszusammenfassung zur Seite Nr. 14
1.1 System Highlights 1.1 System Highlights 1.1.1 System Highlights Built-in Voice Message (BV) (Optional voice message card required) Built-in Voice Message (BV) allows a caller to leave a voice message in a user's personal message area or the PBX's common message area. Fixed Line SMS Terminal Support (Optional Caller ID card required) The PBX can relay incoming calls from a Short Message Service (SMS) centre to specific single line telephones (SLTs) that support SMS. Fixed Line SMS is
Inhaltszusammenfassung zur Seite Nr. 15
1.2 Basic System Construction 1.2 Basic System Construction 1.2.1 Main Unit The KX-TES824 has a basic capacity of 3 outside (CO) lines and 8 extensions, and the KX-TEM824 has a basic capacity of 6 outside (CO) lines and 16 extensions. It is capable of supporting Panasonic proprietary telephones (PTs), and single line devices such as single line telephones (SLTs), fax machines and data terminals. To expand its capabilities, the PBX can be equipped with optional components or user-supplied pe
Inhaltszusammenfassung zur Seite Nr. 16
1.2 Basic System Construction 1.2.2 System Connection Diagram Outside (CO) Line Remote PC Doorphone Door Opener/Doorbell/ Batteries Door Chime BGM/Music on Hold (MOH) PC Printer PC Pager/Amplifier&Speaker SLT PT FAX/Telephone Answering Machine DSS Console Wireless Phone Voice Processing System Connect a display-equipped proprietary telephone (PT) to extension jack 01, as this extension is automatically designated as the manager extension. PTs and single line telephones (SLTs) can be conne
Inhaltszusammenfassung zur Seite Nr. 17
1.3 Specifications 1.3 Specifications 1.3.1 General Description Control Bus Original bus (16-bit, 24 MHz) Switching Space Division CMOS Crosspoint Switch Power Input 100 V AC to 240 V AC, 1.5A to 0.75A, 50 Hz/60 Hz External Battery +24 V DC (+12 V DC × 2) Maximum Power Failure Tolerance 300 ms (without using backup batteries) Memory Backup Duration 7 years Dialling Outside (CO) Line Pulse (10 pps, 20 pps) or Tone (DTMF) Extension Pulse (10 pps, 20 pps) or Tone (DTMF) Intercom Path 4 Mode Convers
Inhaltszusammenfassung zur Seite Nr. 18
1.3 Specifications 1.3.2 Characteristics Terminal Equipment Loop Limit PT 40 Ω SLT 600 Ω including set Doorphone 20 Ω Minimum Leakage Resistance 15 000 Ω minimum Maximum Number of Extension 1 PT or SLT in standard connection Instruments per Line 1 PT and 1 SLT in parallel connection Ring Voltage 75 Vrms at 20 Hz/25 Hz depending on the ringing load Outside (CO) Line Loop Limit 1600 Ω maximum Hookswitch Flash/Recall Timing 24 ms–2032 ms Range Door Opener Current Limit 30 V DC/125 V AC, 3 A maximum
Inhaltszusammenfassung zur Seite Nr. 19
1.3 Specifications 1.3.3 System Capacity System Capacity TES824 TEM824 Basic System Outside (CO) lines 3 6 Extensions 8 16 Fully Expanded System Outside (CO) lines 8 8 Extensions 24 24 Maximum Cards and Terminal Equipment Item TES824 TEM824 PT and SLT 40 40 3-Port Analogue CO Line and 8-Port Hybrid Extension Card 1 — 2-Port Analogue CO Line and 8-Port SLT Extension Card 1 1 8-Port SLT Extension Card 1 1 Message Expansion Card for DISA/UCD OGMs 1 1 4-Port Doorphone Card 1 1 3-Port Caller ID Card
Inhaltszusammenfassung zur Seite Nr. 20
1.3 Specifications Item Max. Quantity Message Waiting 8 per extension Message for Built-in Voice Message 125 messages (total 60 minutes) 20 Installation Manual