Inhaltszusammenfassung zur Seite Nr. 1
General-Purpose AC Servo
J2-Super Series
SSCNET Compatible
MODEL
MR-J2S- B
SERVO AMPLIFIER
INSTRUCTION MANUAL
E
Inhaltszusammenfassung zur Seite Nr. 2
Safety Instructions (Always read these instructions before using the equipment.) Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly. Do not use the servo amplifier and servo motor until you have a full knowledge of the equipment, safety information and instructions. In this Instructi
Inhaltszusammenfassung zur Seite Nr. 3
1. To prevent electric shock, note the following: WARNING Before wiring or inspection, switch power off and wait for more than 10 minutes. Then, confirm the voltage is safe with voltage tester. Otherwise, you may get an electric shock. Connect the servo amplifier and servo motor to ground. Any person who is involved in wiring and inspection should be fully competent to do the work. Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, you may get
Inhaltszusammenfassung zur Seite Nr. 4
4. Additional instructions The following instructions should also be fully noted. Incorrect handling may cause a fault, injury, electric shock, etc. (1) Transportation and installation CAUTION Transport the products correctly according to their weights. Stacking in excess of the specified number of products is not allowed. Do not carry the servo motor by the cables, shaft or encoder. Do not hold the front cover to transport the servo amplifier. The servo amplifier may drop. Install the servo am
Inhaltszusammenfassung zur Seite Nr. 5
CAUTION Securely attach the servo motor to the machine. If attach insecurely, the servo motor may come off during operation. The servo motor with reduction gear must be installed in the specified direction to prevent oil leakage. Take safety measures, e.g. provide covers, to prevent accidental access to the rotating parts of the servo motor during operation. Never hit the servo motor or shaft, especially when coupling the servo motor to the machine. The encoder may become faulty. Do not subject
Inhaltszusammenfassung zur Seite Nr. 6
(4) Usage CAUTION Provide a forced stop circuit to ensure that operation can be stopped and power switched off immediately. Any person who is involved in disassembly and repair should be fully competent to do the work. Before resetting an alarm, make sure that the run signal of the servo amplifier is off to prevent an accident. A sudden restart is made if an alarm is reset with the run signal on. Do not modify the equipment. Use a noise filter, etc. to minimize the influence of electromagnetic
Inhaltszusammenfassung zur Seite Nr. 7
(6) Maintenance, inspection and parts replacement CAUTION With age, the electrolytic capacitor of the servo amplifier will deteriorate. To prevent a secondary accident due to a fault, it is recommended to replace the electrolytic capacitor every 10 years when used in general environment. Please consult our sales representative. (7) General instruction To illustrate details, the equipment in the diagrams of this Instruction Manual may have been drawn without covers and safety guards. When the eq
Inhaltszusammenfassung zur Seite Nr. 8
COMPLIANCE WITH EC DIRECTIVES 1. WHAT ARE EC DIRECTIVES? The EC directives were issued to standardize the regulations of the EU countries and ensure smooth distribution of safety-guaranteed products. In the EU countries, the machinery directive (effective in January, 1995), EMC directive (effective in January, 1996) and low voltage directive (effective in January, 1997) of the EC directives require that products to be sold should meet their fundamental safety requirements and carry the CE marks
Inhaltszusammenfassung zur Seite Nr. 9
(4) Power supply (a) Operate the servo amplifier 7kW or less to meet the requirements of the overvoltage category II set forth in IEC60664-1. For this purpose, a reinforced insulating transformer conforming to the IEC or EN standard should be used in the power input section. Since the 11kW or more servo amplifier can be used under the conditions of the overvoltage category III set forth in IE644, a reinforced insulating transformer is not required in the power input section. (b) When supplying i
Inhaltszusammenfassung zur Seite Nr. 10
CONFORMANCE WITH UL/C-UL STANDARD (1) Servo amplifiers and servo motors used Use the servo amplifiers and servo motors which comply with the standard model. Servo amplifier :MR-J2S-10B to MR-J2S-22KB MR-J2S-10B1 to MR-J2S-40B1 Servo motor :HC-KFS HC-MFS HC-SFS HC-RFS HC-UFS HA-LFS HC-LFS (2) Installation 3 Install a fan of 100CFM (2.8m /min) air flow 4 in (10.16 cm) above the servo amplifier or provide cooling of at least equivalent capability. (3) Short circuit rating This servo a
Inhaltszusammenfassung zur Seite Nr. 11
<> This Instruction Manual and the MELSERVO Servo Motor Instruction Manual are required if you use the General-Purpose AC servo MR-J2S-B for the first time. Always purchase them and use the MR- J2S-B safely. Also read the manual of the servo system controller. Relevant manuals Manual name Manual No. MELSERVO-J2-Super Series To Use the AC Servo Safely IB(NA)0300010 (Packed with the servo amplifier) MELSERVO Servo Motor Instruction Manual SH(NA)3181 EMC Installation Guidelines I
Inhaltszusammenfassung zur Seite Nr. 12
CONTENTS 1. FUNCTIONS AND CONFIGURATION 1- 1 to 1-22 1.1 Introduction.............................................................................................................................................. 1- 1 1.2 Function block diagram .......................................................................................................................... 1- 2 1.3 Servo amplifier standard specifications ....................................................................................
Inhaltszusammenfassung zur Seite Nr. 13
3.12 Power line circuit of the MR-J2S-11KB to MR-J2S-22KB............................................................... 3-29 3.12.1 Connection example ...................................................................................................................... 3-29 3.12.2 Servo amplifier terminals ............................................................................................................. 3-30 3.12.3 Servo motor terminals................................................
Inhaltszusammenfassung zur Seite Nr. 14
9. TROUBLESHOOTING 9- 1 to 9- 8 9.1 Alarms and warning list ......................................................................................................................... 9- 1 9.2 Remedies for alarms................................................................................................................................ 9- 2 9.3 Remedies for warnings............................................................................................................................ 9- 8 1
Inhaltszusammenfassung zur Seite Nr. 15
Appendix App- 1 to App- 2 App. Combination of servo amplifier and servo motor ......................................................................... App- 1 4
Inhaltszusammenfassung zur Seite Nr. 16
Optional Servo Motor Instruction Manual CONTENTS The rough table of contents of the optional MELSERVO Servo Motor Instruction Manual is introduced here for your reference. Note that the contents of the Servo Motor Instruction Manual are not included in the Servo Amplifier Instruction Manual. 1. INTRODUCTION 2. INSTALLATION 3. CONNECTORS USED FOR SERVO MOTOR WIRING 4. INSPECTION 5. SPECIFICATIONS 6. CHARACTERISTICS 7. OUTLINE DIMENSION DRAWINGS 8. CALCULATION METHODS FOR DESIGNING 5
Inhaltszusammenfassung zur Seite Nr. 17
MEMO 6
Inhaltszusammenfassung zur Seite Nr. 18
1. FUNCTIONS AND CONFIGURATION 1. FUNCTIONS AND CONFIGURATION 1.1 Introduction The Mitsubishi MELSERVO-J2-Super series general-purpose AC servo is based on the MELSERVO-J2 series and has further higher performance and higher functions. It is connected with a servo system controller or similar device via a serial bus (SSCNET) and the servo amplifier reads position data directly to perform operation. Data from a command unit controls the speed and rotation direction of the servo motor and executes
Inhaltszusammenfassung zur Seite Nr. 19
1. FUNCTIONS AND CONFIGURATION 1.2 Function block diagram The function block diagram of this servo is shown below. (1) MR-J2S-350B or less Regenerative brake option Servo amplifier P D Servo motor C (Note 2) (Note 1) DS RA Power NFB MC U U L1 supply 3-phase V V Current L2 M 200 to detector W W L3 230VAC, Regenerative CHARGE TR 1-phase lamp 230VAC or Dynamic 1-phase Fan brake 100to120VAC (MR-J2S-200B or more) E1 Control Electro- L11 circuit magnetic E2 L21 power brake supply Base amplifier Regene
Inhaltszusammenfassung zur Seite Nr. 20
1. FUNCTIONS AND CONFIGURATION (2) MR-J2S-500B, MR-J2S-700B Regenerative brake option Servo amplifier Servo motor P C N DS RA Power NFB MC U U L1 supply 3-phase V V Current L2 M 200 to detector W W L3 Regenerative 230VAC CHARGE TR lamp Dynamic Fan brake E1 Control Electro- L11 circuit magnetic E2 L21 power brake supply Base amplifier Regenerative Voltage Overcurrent Current detection protection detection brake Encoder Virtual Position command encoder input Model position Model speed control cont