Inhaltszusammenfassung zur Seite Nr. 1
AT-GS950/24
Gigabit Ethernet Smart Switch
How to Start a WEB
Management Session
613-001499 Rev B
Inhaltszusammenfassung zur Seite Nr. 2
Copyright © 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc. reserves the right to make changes in specifications and other inf
Inhaltszusammenfassung zur Seite Nr. 3
How to Start an AT-GS950/24 WEB Management Session This document contains the procedures to start you Web management session on the AT-GS950/24 switch. The following topics are discussed: “Establishing a Remote Connection to the Web Browser Interface” on page 4 “Web Browser Tools” on page 8 “Configuration of IP Address, Subnet Mask and Gateway Address” on page 9 “IP Access List Configuration” on page 11 “DHCP Client Configuration” on page 18 “System Management Information” on pag
Inhaltszusammenfassung zur Seite Nr. 4
How to Start an AT-GS950/24 WEB Management Session Establishing a Remote Connection to the Web Browser Interface The AT-GS950/24 switch is shipped with a pre-assigned IP address of 192.168.1.1. After your initial login, you may want to assign a new IP address to your switch. To manually assign an IP address to the switch, refer to “Configuring an IP Address, Subnet Mask and Gateway Address” on page 10. To configure the switch to obtain its IP configuration from a DHCP server, refer to “Ena
Inhaltszusammenfassung zur Seite Nr. 5
How to Start an AT-GS950/24 WEB Management Session The AT-S109 Management Software displays the login dialog box, shown in Figure 2. Figure 2. Management Login Dialog Box 3. Enter the AT-S109 management login user name and password. The default user name is “manager” and the default password is “friend.” 4. Press OK. The login name and password are case-sensitive. The switch Home Page is displayed. See Figure 3 on page 6 for an example of the AT-S109 Home Page. To change the user name and
Inhaltszusammenfassung zur Seite Nr. 6
How to Start an AT-GS950/24 WEB Management Session Figure 3. AT-S109 Home Page The main menu appears on the left side and is common for all of the management pages discussed in this manual. It consists of the following folders and web pages: Switch Info. Front Panel System Physical Interface Bridge SNMP Access Control RMON Voice VLAN Security LLDP Statistics Chart Tools Save Configuration 6
Inhaltszusammenfassung zur Seite Nr. 7
How to Start an AT-GS950/24 WEB Management Session 5. To see the front panel of the switch, select Front Panel from the main menu on the left side of the page. The AT-S109 Management software displays the front of the switch. Ports that have a link to an end node are green. Ports without a link are grey. The AT-GS950/24 switch front panel page is shown in Figure 4. Figure 4. AT-GS950/24 Front Panel Page A web browser management session remains active even if you link to other sites. You can
Inhaltszusammenfassung zur Seite Nr. 8
How to Start an AT-GS950/24 WEB Management Session Web Browser Tools You can use the web browser tools to move around the management pages. Selecting Back on your browser’s toolbar returns you to the previous display. You can also use the browser’s bookmark feature to save the link to the switch. 8
Inhaltszusammenfassung zur Seite Nr. 9
How to Start an AT-GS950/24 WEB Management Session Configuration of IP Address, Subnet Mask and Gateway Address This procedure explains how to change the IP address, subnet mask, and gateway address of the switch. Before performing the procedure, note the following: A gateway address is only required if you want to remotely manage the device from a management station that is separated from the switch by a router. To configure the switch to automatically obtain its IP configuration from
Inhaltszusammenfassung zur Seite Nr. 10
How to Start an AT-GS950/24 WEB Management Session System Default Gateway - Displays the default gateway of the switch. To change the default gateway, enter a new gateway. When DHCP is enabled, you cannot change this parameter. DHCP Mode - For information about setting this parameter, refer to “DHCP Client Configuration” on page 18. 4. Click Apply. Note Changing the IP address ends your management session. To resume managing the device, enter the new IP address of the switch in the web brows
Inhaltszusammenfassung zur Seite Nr. 11
How to Start an AT-GS950/24 WEB Management Session IP Access List Configuration When the IP Access List feature is enabled, remote access to the AT-S109 management software is restricted to the IP addresses entered into the IP Access List. The procedures in this section describe how to enable or disable the IP Access List feature and how to add or remove IP addresses from the list. See the following sections: “Create an IP Access List” on page 11 “Delete an IP Address List Entry” on page
Inhaltszusammenfassung zur Seite Nr. 12
How to Start an AT-GS950/24 WEB Management Session Note You can add up to 10 IP address to the IP Access List table. 12
Inhaltszusammenfassung zur Seite Nr. 13
How to Start an AT-GS950/24 WEB Management Session 5. From the IP Restriction Status field, select one of the following choices from the pull-down menu: Enable - This selection restricts the access to the AT-S109 management software to the IP addresses in the table listed under Accessible IP. Disable - This selection allows unrestricted access to the AT-S109 management software. 6. Click Apply. Access to the management software is now restricted to those IP addresses listed in the IP Access
Inhaltszusammenfassung zur Seite Nr. 14
How to Start an AT-GS950/24 WEB Management Session System Time The procedures in this section describe how to configure the system time by manually entering the time or through SNTP and how to configure the daylight savings time feature. See the following sections: “Manually Setting System Time” on page 14 “Setting SNTP” on page 15 “Setting Daylight Savings Parameters” on page 16 Manually Setting To set the system time manually, perform the following procedure: System Time 1. From the ma
Inhaltszusammenfassung zur Seite Nr. 15
How to Start an AT-GS950/24 WEB Management Session 3. Use the pull down menu to set the Clock Mode parameter to Local time. 4. In the Local Time Settings section, set the Date Setting (YYYY:MM:DD) to the current date in the YYYY:MM:DD format. 5. In the Local Time Settings section, set the Time Settings (HH:MM:SS) to the current time in the HH:MM:SS format. 6. Click the Apply button at the bottom of the page. The time will take effect immediately. 7. Save your new settings or any changes to th
Inhaltszusammenfassung zur Seite Nr. 16
How to Start an AT-GS950/24 WEB Management Session Setting Daylight If you want to configure the switch for daylight savings time, perform the following procedure: Savings Parameters 1. From the main menu on the left side of the page, click the System folder. The System folder expands. 2. From the System folder, select System Time. The System Time Page is displayed. See Figure 7 on page 14. 3. In the Daylight Savings Time Status field, select Enabled. 4. Specify the Month, Day, Hour and Minute
Inhaltszusammenfassung zur Seite Nr. 17
How to Start an AT-GS950/24 WEB Management Session DHCP and ATI Web Discovery Tool The AT-GS950/24 Gigabit Ethernet Smart switch is managed through a web browser interface only. The factory default IP address is 192.168.1.1. The switch does not have a local console connector, which means that you cannot learn what the switch’s management IP address is on a web browser without first knowing what the address is. Once the IP address is known, you can enter it in the browser. When the DHCP feat
Inhaltszusammenfassung zur Seite Nr. 18
How to Start an AT-GS950/24 WEB Management Session DHCP Client Configuration This procedure explains how to activate and deactivate the DHCP client on the AT-GS950/24 switch. When the client is activated, the switch obtains its IP configuration including an IP address and subnet mask from a DHCP server on your network. Before performing the procedure, note the following: By default, the DHCP client is disabled on the switch. The DHCP client supports DHCP Auto Configuration Settings or
Inhaltszusammenfassung zur Seite Nr. 19
How to Start an AT-GS950/24 WEB Management Session Note The ATI Web Discovery Tool is available for download on the AT-GS950/24 product page at alliedtelesis.com. 6. Follow the procedure to log on with the new IP address provided by the DHCP Server as described in “Establishing a Remote Connection to the Web Browser Interface” on page 4. 7. Save your new settings or any changes to the configuration file by selecting Save Configuration to Flash from the main menu on the left side of the page
Inhaltszusammenfassung zur Seite Nr. 20
How to Start an AT-GS950/24 WEB Management Session DHCP Auto Configuration If you need to automatically update the switch’s configuration files via a remote server, the DHCP Auto Configuration feature is available for this purpose via the DHCP server. Note You must enable the DHCP client so that this feature can operate with the DHCP server. See “DHCP Client Configuration” on page 18 for more information. To configure this feature on the switch, perform the following procedure: 1. From the