Inhaltszusammenfassung zur Seite Nr. 1
RuggedSwitch™
RS900GP
Hardware Installation Guide
Revision 100 - November 10, 2011
www.RuggedCom.com
Inhaltszusammenfassung zur Seite Nr. 2
RuggedSwitch™ RS900GP RuggedSwitch™ RS900GP: Hardware Installation Guide Copyright © 2011 RuggedCom Inc. All Rights Reserved Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights are reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All ri
Inhaltszusammenfassung zur Seite Nr. 3
RuggedSwitch™ RS900GP Table of Contents FCC Statement And Cautions ................................................................................................... 6 1. Product Overview ................................................................................................................... 7 1.1. RS900GP Front Panel ................................................................................................ 9 2. Installation .....................................................
Inhaltszusammenfassung zur Seite Nr. 4
RuggedSwitch™ RS900GP List of Figures 1.1. RS900GP Front Panel ........................................................................................................ 9 2.1. DIN Rail Mounting ............................................................................................................ 10 2.2. Front Panel Mounting ....................................................................................................... 11 2.3. Rear Panel Mounting .....................................
Inhaltszusammenfassung zur Seite Nr. 5
RuggedSwitch™ RS900GP List of Tables 1.1. Front Panel LED Definitions ............................................................................................... 9 2.1. RS232 Female DCE Pinout .............................................................................................. 15 2.2. RJ45 Ethernet Pin Assignment ......................................................................................... 16 3.1. Operating Environment ...................................................
Inhaltszusammenfassung zur Seite Nr. 6
FCC Statement And Cautions FCC Statement And Cautions Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed
Inhaltszusammenfassung zur Seite Nr. 7
1. Product Overview 1. Product Overview The RuggedSwitch™ RS900GP is an industrially hardened, fully managed Ethernet switch providing dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports - each capable of supplying high power 802.3at compliant power over Ethernet. Designed to operate reliably in harsh industrial environments, the RS900GP provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electr
Inhaltszusammenfassung zur Seite Nr. 8
1. Product Overview Power Supply • 2 (redundant) 54VDC inputs (51-57VDC) • Supports 8 30W PoE powered devices (minimum 260W total output) • Supports power supply sharing • Reverse polarity protection • CSA/UL 60950 safety approved to +85°C Simple Plug and Play Operation • Plug and play operation 802.3af/802.3at • Automatic learning of up to 8192 MAC addresses • Auto-negotiation on all 10/100BaseTX ports • Auto-MDI/MDIX (crossover) on all 10/100BaseTX ports • LED indicators for Link/Activity and
Inhaltszusammenfassung zur Seite Nr. 9
1. Product Overview 1.1. RS900GP Front Panel Figure 1.1. RS900GP Front Panel LED Indicator LED Color and State Description Power LED Green, steady. Power is on. Alarm LED Red, steady. Alarm condition exists. Ethernet Port 1-8 Link LED Green, steady. Network link. Ethernet Port 1-8 Link LED Green, blinking. Network activity. Ethernet Port 1-8 PoE LED Orange, steady. PoE is enabled and powered on. Ethernet Port 1-8 PoE LED Orange, blinking. PoE is enabled and powered off. Ethernet Port 1-8 PoE LED
Inhaltszusammenfassung zur Seite Nr. 10
2. Installation 2. Installation 2.1. DIN Rail Mounting An optional DIN rail mounting bracket is available for the RS900GP. Figure 2.1. DIN Rail Mounting RuggedCom® RuggedSwitch™ 10 RS900GP Installation Guide Rev 100
Inhaltszusammenfassung zur Seite Nr. 11
2. Installation 2.2. Panel Mounting Options The RS900GP can be equipped with front, rear, or side panel mount brackets. 2.2.1. RS900GP Front Panel Mount Option The front panel mounting brackets fit flush with the front of the RS900GP. Figure 2.2. Front Panel Mounting RuggedCom® RuggedSwitch™ 11 RS900GP Installation Guide Rev 100
Inhaltszusammenfassung zur Seite Nr. 12
2. Installation 2.2.2. RS900GP Rear Panel Mount Option The rear panel mounting brackets fit flush with the rear of the RS900GP. Figure 2.3. Rear Panel Mounting RuggedCom® RuggedSwitch™ 12 RS900GP Installation Guide Rev 100
Inhaltszusammenfassung zur Seite Nr. 13
2. Installation 2.2.3. RS900GP Side Panel Mount Option The side panel mounting brackets fit flush with the side of the RS900GP. Figure 2.4. Side Panel Mounting RuggedCom® RuggedSwitch™ 13 RS900GP Installation Guide Rev 100
Inhaltszusammenfassung zur Seite Nr. 14
2. Installation 2.3. DC Power Supply Wiring and Grounding Figure 2.5. DC Power Supply Wiring and Grounding The RS900GP low voltage DC power supply features reverse polarity protection and dual independent inputs. This feature allows the connection of two DC sources with the same nominal voltage to provide redundant power supply inputs. The DC source must be connected to the DC inputs according to the polarity markings on the unit. 1. Equipment must be installed according to the applicable countr
Inhaltszusammenfassung zur Seite Nr. 15
2. Installation 2.4. Failsafe Output Wiring and Specifications The “Failsafe” output relay is provided to signal critical error conditions that may occur on the RS900GP. The contacts are energized upon power up of the unit and remain energized until an alarm condition or power loss occurs. Figure 2.7. Failsafe Output Relay 2.5. RS232 Port Wiring The RS232 port is used for configuring the unit. A straight-through serial cable with a DB-9 connector is required. There is no need to crossover the T
Inhaltszusammenfassung zur Seite Nr. 16
2. Installation 2.6. RJ45 Ports: Signal Description The RS900GP has several 10/100BaseTX ports that allow connection to standard CAT-5 UTP cable with RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis ground on the unit and can accept shielded CAT-5 cables. If shielded cables are used, care must be taken to ensure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Figure 2.9. RJ45 Port Connector RJ45 Pin 10/100B
Inhaltszusammenfassung zur Seite Nr. 17
3. Specifications 3. Specifications 3.1. Operating Environment Parameter Range Comments Ambient Temperature as measured Ambient Operating Temperature -40 to 85°C from a 30cm radius surrounding the center of the RS900GP enclosure. Ambient Relative Humidity 5% to 95% Non-condensing Ambient Storage Temperature -40 to 85°C Operating Altitude 0 to 15240m (0 to 50000 ft) Over temperature range of -40 to 85°C Table 3.1. Operating Environment 3.2. Power Supply Specifications 3.2.1. General RS900GP Maxi
Inhaltszusammenfassung zur Seite Nr. 18
3. Specifications 3.4. Twisted Pair Data Port Specifications Data Port Media Distance Connector Type 10/100 Mbps Cat 5 UTP or STP 100m RJ45 Table 3.6. Twisted Pair Data Port Specifications RuggedCom® RuggedSwitch™ 18 RS900GP Installation Guide Rev 100
Inhaltszusammenfassung zur Seite Nr. 19
3. Specifications 3.5. Fiber Optic Port Specifications For maximum flexibility, RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optic communications. The following table details fiber optic specifications based on the order code/transceiver selected at time of ordering. Typical Mode / Cable Tx Pwr (dBm) Rx Sensitivity Rx Saturation Order Code Distance Tx λ (nm) a b b b Connector Type 1. (Min/Max) (dBm) (dBm) c (km) 2LCMM MM / LC 850 -9.5 / -4 -20 0 0.5 50μ/125
Inhaltszusammenfassung zur Seite Nr. 20
3. Specifications 3.6. Physical Dimensions Figure 3.1. RS900GP Physical Dimensions Parameter Value Comments 6.95 × 3.63 × 6.08 inches Dimensions (Length × Width × Depth ( 17.653 × 9.22 × 14.4432 cm) Weight To be determined Ingress Protection IP40 (1mm objects) Enclosure Cast Aluminum Table 3.8. Physical Specifications RuggedCom® RuggedSwitch™ 20 RS900GP Installation Guide Rev 100