Inhaltszusammenfassung zur Seite Nr. 1
Data Multiplex Unit
Operating Instructions
Model No. WJ-MP204C
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
ALARM
ALARM
SUSPEND
Data Multiplex Unit WJ-MP204C
POWER
ON
OFF
Inhaltszusammenfassung zur Seite Nr. 2
ENGLISH VERSION Caution: Before attempting to connect or operate this product, please read the label on the bottom. For U.S.A NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part CAUTION 15 of the FCC Rules. These limits are designed to provide RISK OF ELECTRIC SHOCK reasonable protection against harmful interference when the DO NOT OPEN equipment is operated in a commercial environment. This equipment generates, uses, and can ra
Inhaltszusammenfassung zur Seite Nr. 3
IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not use near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polarize
Inhaltszusammenfassung zur Seite Nr. 4
CONTENTS IMPORTANT SAFETY INSTRUCTIONS ........................................................................................................................................ 3 PREFACE ...................................................................................................................................................................................... 5 FEATURES ........................................................................................................................
Inhaltszusammenfassung zur Seite Nr. 5
PREFACE The Data Multiplex Unit WJ-MP204C is designed for instal- The monitor and system controller can be located distant lation in a surveillance system, offering system flexibility from the camera site thanks to the use of a coaxial cable particularly when camera control functions are required. and an RS-485 cable. The unit multiplexes video signals with control data and The unit includes two protocols, Panasonic Security Data • VD2 sync into a coaxial cable. This makes installations (PS Dat
Inhaltszusammenfassung zur Seite Nr. 6
PRECAUTIONS • Refer all work related to the installation of this • Do not expose the appliance to water or moisture, product to qualified service personnel or system nor try to operate it in wet areas. installers. Do take immediate action if the appliance becomes wet. Turn the power off and refer servicing to qualified • Do not block the ventilation opening or slots on the service personnel. Moisture can damage the appliance cover. and also cause electric shock. To prevent the appliance temperat
Inhaltszusammenfassung zur Seite Nr. 7
4 3 2 1 SWITCH PROTECTOR MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS Front View !2 q w e r t UNIT ALARM 0 POWER ALARM RESET SUSPEND SET UP ALARM SUSPEND SET ESC ON 12 3 4 OFF Data Multiplex Unit WJ-MP204C y u i o !0 !1 q Power switch and power Indicator (POWER ON OFF) t Setup/escape button (SETUP/ESC) To turn on or off the power of the unit, press the switch. Holding down this button opens or closes the setup The indicator is lit while the power is supplied. menu. Note: Use the switch protec
Inhaltszusammenfassung zur Seite Nr. 8
Rear View @1 @3 @5 @7 #1 #2 ALARM / REMOTE IN 43 2 1 IN IN T R G B A B A SIGNAL GND OUT 43 2 1 OUT OUT SPOT VS/VD DATA MODE CAMERA RS485 @8 @2 @4 @6 @9 #0 @1 Camera Input Connector 1-4 (CAMERA IN 1 2 3 4) @6 VS/VD Output Connector (VS/VD OUT) These connectors accept the composite video signal Supplies a sync signal depending on the input to the supplied by the cameras while passing through the VS/VD IN connector and setting of the MODE DIP control data and VD2 sync signal. switch #1. Refer to
Inhaltszusammenfassung zur Seite Nr. 9
INSTALLATION Warning! Only qualified service personnel or system installers should make all rack mountings, connections or internal settings. If adjustments are required, please refer to the Service Manual available for this product. Mounting in the Rack Rubber feet Remove the four rubber feet by removing the four screws from the bottom of the WJ-MP204C. Mounting One WJ-MP204C with the WV-Q204/1 1. Fix the mounting brackets (large and small) on both sides of the WJ-MP204C with the eight su
Inhaltszusammenfassung zur Seite Nr. 10
CONNECTION & SETTING • Shown below are some system connection examples using Data Multiplex unit with peripheral devices in PS Data (Panasonic Security Data) or the Camera Communication Protocols. Note that all system devices in a system should use the same proto- col. • Basic Connection (PS Data) Up to four cameras are connected with the unit at a camera site while a System Controller operates camera selection, pan/tilt and lens control at a control site. Camera 1 ch 4 ch 2 ch 3 ch Camera Sit
Inhaltszusammenfassung zur Seite Nr. 11
7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 • Multi-unit Connection (PS Data) A maximum of four units can be connected in a daisy fashion, from SPOT OUT to SPOT IN and so on, and finally from SPOT OUT to the monitor. 11 2 2 2 2 1 1 1 1 5 ch 13 ch 8 ch 16 ch 1 ch 9 ch 6 ch 14 ch 2 ch 10 ch Camera Site 7 ch 15 ch 3 ch 11 ch 4 ch 12 ch VS/VD IN VS/VD OUT VS/VD IN VS/VD OUT VS/VD IN VS/VD OUT SPOT OUT SPOT IN SPOT IN SPOT IN SPOT OUT SPOT OUT SPOT SW IN OUT IN OUT IN SPOT SW OUT Unit Address 1 Unit Ad
Inhaltszusammenfassung zur Seite Nr. 12
4 4 3 3 2 2 1 1 • Video Multiplexer Connection (PS Data) To connect with ordinary cameras that do not have camera control functions, a Video Multiplexer is installed with the WJ- MP204C units at the camera site. 1 ch 5 ch 4 ch 6 ch 2 ch Camera Site 3 ch 7 ch 8 ch VS/VD OUTPUT VS/VD INPUT UNIT UNIT 0 0 Unit Address 2 Unit Address 1 IN 43 2 1 IN IN ALARM / REMOTE IN 43 2 1 IN IN ALARM / REMOTE SD RD TR G B A B A G B A B A SIGNAL GND SIGNAL GND OUT 43 2 1 OUT OUT OUT 43 2 1 OUT OUT CAMERA SPOT VS
Inhaltszusammenfassung zur Seite Nr. 13
• Digital Disk Recorder Connection (PS Data) To connect with ordinary cameras that do not have camera control functions, a Digital Disk Recorder is installed with the WJ- MP204C units at the camera site. When an optional Network Interface Board is installed in the recorder, monitoring via the Internet is available. For more information, refer to the manual included with the recorder. WJ-MP204C WJ-MP204C POWER ALARM ALARM SUSPEND POWER ALARM ALARM SUSPEND ON ON OFF OFF Data Multiplex Unit WJ-MP
Inhaltszusammenfassung zur Seite Nr. 14
4 4 3 3 2 2 1 1 Matrix Switcher Connection (Camera Communication) The WJ-SX350 and WV-CU360C are typically combined with the WJ-MP204C when using the Camera Communication Protocol. Ordinary cameras are connected directly with the Matrix Switcher, different from cameras having control functions. Camera Camera 1 ch 5 ch 4 ch 2 ch 6 ch 3 ch 7 ch 8 ch UNIT 0 UNIT Data Multiplex Unit Data Multiplex Unit 0 WJ-MP204C WJ-MP204C Unit Address 2 Unit Address 1 ALARM / REMOTE ALARM / REMOTE IN 43 2 1 IN I
Inhaltszusammenfassung zur Seite Nr. 15
4 3 2 1 DIP Switch Setting A 6-bit DIP switch mounted on the rear panel specifies communication mode and sync setup. The default position is marked with an asterisk * in the table below. Bit 1 specifies the setup for synchronization. Refer to page 23 VS/VD IN and OUT for details. Bit 2 is reserved. Bit 3 specifies the communication protocol used in the system. Bit 4 is reserved. Bit 5 specifies the termination in the communication chain. • Bit 6 specifies RS-485 communication mode conducted
Inhaltszusammenfassung zur Seite Nr. 16
• 8 PS Data Address Assignment UNIT Switch Position 0 1 2 3 4 5 6 7 8 9 Set the Do not Unit address number in 1 2 3 4 5 6 7 8 use, Setup given to WJ-MP204C reserved menu 8 Camera Communication Protocol As shown in the table, the UNIT switch determines the camera unit numbers. Address Assignment UNIT Switch Position 0 1 2 3 4 5 6 7 8 9 1 1 5 9 13 17 21 25 29 Set the Do not 2 2 6 10 14 18 22 26 30 Connector number in use, CAMERA IN/OUT Setup 3 3 7 11 15 19 23 27 31 reserved menu 4 4 8 12 16 20
Inhaltszusammenfassung zur Seite Nr. 17
8 Alarm input Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector remains in the default position (CN703, ALM IN): Pin #6 accepts CH 1 alarm input from the connected sensor. Pin #7 accepts CH 2 alarm input from the connected sensor. Pin #8 accepts CH 3 alarm input from the connected sensor. Pin #9 accepts CH 4 alarm input from the connected sensor. 8 Alarm output Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in th
Inhaltszusammenfassung zur Seite Nr. 18
• Basic Connection Data Multiplex Unit System Controller WJ-MP204C WV-CU360C DATA DATA Termination: Termination: ON ON RS-485 Cable • Daisy Connection Video Multiplexer Data Multiplex Unit System Controller WJ-FS309 (WJ-FS316) WJ-MP204C WV-CU360C DATA DATA DATA Termination: Termination: Termination: Branch ON OFF ON Cable RS-485 RS-485 Cable Cable RS-485 Terminal Connection (Camera Communication) 8 4-line Full Duplex These terminals are connected with system devices using the Camera Communica
Inhaltszusammenfassung zur Seite Nr. 19
4 3 2 1 SETUP PROCEDURES WJ-MP204C SETUP MENUX.XX Prior to setup Confirmation COMMUNICATION SYSTEM 1. Connections and switch settings are complete. 2. Switch on the power of the connected system devices including the monitor that displays the menus. 3. Turn on the power of the WJ-MP204C. 4. When setting at the camera site, remove the front cover from the unit to make access possible to the buttons on the front panel. 5. When setting with use of a WV-CU360C System On the window, you ca
Inhaltszusammenfassung zur Seite Nr. 20
Setup menus • There are two setup menu groups depending on the communication protocol used in the system, menus for PS Data and for the Camera Communication Protocol. MODE DIP switch # 3 on the rear of the unit is set to the position of the used protocol, and it specifies what menu group is displayed on the monitor. Menu trees are shown below for two protocols. • Setup menus for PS Data Setup menus for Camera Communication Protocol COMMUNICATION COMMUNICATION UNIT ADDRESS CAM ADDRES