Inhaltszusammenfassung zur Seite Nr. 1
EMC Enterprise Storage
Departmental Switch
Model DS-16B2
Fabric OS
Version 3.0
PROCEDURES MANUAL
P/N 069001111-A01
EMC Corporation 171 South Street, Hopkinton, MA 01748-9103
Corporate Headquarters: (508) 435-1000, (800) 424-EMC2 Fax: (508) 435-5374 Service: (800) SVC-4EMC
Inhaltszusammenfassung zur Seite Nr. 2
Copyright © 2001 EMC Corporation. All rights reserved. Printed September, 2001 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPO
Inhaltszusammenfassung zur Seite Nr. 3
Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Any modifications to this device - unless expressly approved by the manufacturer - can void the User authority to operate this equipment under part 15 of the FCC rules. Trademark Information EMC, EMC2, Symmetrix, and CLARiiON are registered trademarks and where information lives is a trademark
Inhaltszusammenfassung zur Seite Nr. 4
iv Departmental Switch DS-16B2 Fabric OS Procedures Manual
Inhaltszusammenfassung zur Seite Nr. 5
Contents Preface .......................................................................................................................... vii Chapter 1 Setting the Initial Switch Configuration Logging In to a Switch .................................................................... 1-2 Enabling Licensed Features............................................................ 1-3 Displaying the Installed Feature Licenses.................................... 1-4 Changing the Admin Password and User
Inhaltszusammenfassung zur Seite Nr. 6
Contents Displaying Help Information for a Telnet Command.............. 2-11 Reading Hexadecimal Port Diagrams ........................................ 2-12 Chapter 3 Displaying Error Logs and Status Displaying the Status of a Port ...................................................... 3-2 Displaying Software Statistics for a Port............................... 3-2 Displaying Hardware Statistics for a Port ............................ 3-2 Displaying a Summary of Port Errors .....................
Inhaltszusammenfassung zur Seite Nr. 7
Preface The Departmental Switch Model DS-16B2 Fabric OS Procedures Manual provides procedures for many of the basic tasks of administrating and configuring a DS-16B2 switch through the Telnet interface. For tasks related to specific features such as Zoning or QuickLoop, refer to the individual product guides. If a Departmental Switch Model DS-16B2 feature does not function properly or does not function as described in this manual, please contact the EMC Customer Support Center for assistan
Inhaltszusammenfassung zur Seite Nr. 8
Preface Chapter 3, Displaying Error Logs and Status, provides instructions for displaying port and switch status information. Appendix A, Customer Support, describes the procedure for contacting EMC Corporation when you need help with the Departmental Switch Model DS-16B2. The Glossary provides explanations for terminology used in this manual. Related Departmental Switch Model DS-16B2 Hardware Reference Manual Documentation Departmental Switch DS-16B2 Fabric OS Reference Manual D
Inhaltszusammenfassung zur Seite Nr. 9
Preface WARNING A warning contains information essential to avoid a hazard that can cause severe personal injury, death, or substantial property damage if you ignore the warning. DANGER A danger notice contains information essential to avoid a hazard that will cause severe personal injury, death, or substantial property damage if you ignore the message. Typographical Conventions EMC uses the following type style conventions in this manual: AVANT GARDE Keystrokes Palatino, Dialog box, butto
Inhaltszusammenfassung zur Seite Nr. 10
Preface Where to Get Help Obtain technical support by calling your local sales office. For service, call: United States: (800) 782-4362 (SVC-4EMC) Canada: (800) 543-4782 (543-4SVC) Worldwide: (508) 497-7901 and ask for Customer Support. If you are located outside the USA, call the nearest EMC office for technical assistance. Sales and Customer For the list of EMC sales locations, please access the EMC home page Service Contacts at: http://www.emc.com/contact/ For additional information on the
Inhaltszusammenfassung zur Seite Nr. 11
1 Invisible Body Tag Setting the Initial Switch Configuration The Departmental Switch Model DS-16B2 requires a connection to your IP network. This chapter provides information on how to set up initial configuration tasks for a switch. Logging In to a Switch.......................................................................1-2 Enabling Licensed Features..............................................................1-3 Displaying the Installed Feature Licenses......................
Inhaltszusammenfassung zur Seite Nr. 12
Setting the Initial Switch Configuration 1 Logging In to a Switch The switch must be connected to an IP network through the RJ-45 port to enable a connection through Telnet. Refer to the Departmental Switch DS-16B2 Hardware Reference Manual for more information about connecting the switch to your IP network. To log into a Departmental Switch DS-16B2 switch: 1. Open a Telnet connection to the switch. The login prompt displays if the Telnet connection successfully found the switch in the netw
Inhaltszusammenfassung zur Seite Nr. 13
Setting the Initial Switch Configuration 1 Enabling Licensed Features Licensed features such as Departmental Switch DS-16B2 Fabric Watch, Departmental Switch DS-16B2 Extended Fabrics, and Departmental Switch DS-16B2 ISL Trunking are already loaded onto the switch firmware, but you must enable them with a license key. Once you purchase these features, you receive a key to unlock the feature. To enable a licensed feature: 1. Log in to the switch as the admin user. 2. At the command line, ent
Inhaltszusammenfassung zur Seite Nr. 14
Setting the Initial Switch Configuration 1 Displaying the Installed Feature Licenses To display what features have been enabled on a switch: 1. Log in to the switch as the admin user. 2. At the command line, enter the following command: licenseShow This command displays the license keys that have been entered for the switch and the features enabled by those licenses. Changing the Admin Password and User ID ® EMC recommends that you change the admin user ID and system password the first time yo
Inhaltszusammenfassung zur Seite Nr. 15
Setting the Initial Switch Configuration 1 Configuring the IP Address The Departmental Switch DS-16B2 switch is shipped with a default IP address of 10.77.77.77. To change the default IP Address and configure the Fibre Channel IP address of the switch: 1. Login to the switch as the admin user. 2. At the command line, enter the following command: ipAddrSet 3. An interactive session opens and prompts you for configuration values. a. Press ENTER without entering a value to skip over a prompt a
Inhaltszusammenfassung zur Seite Nr. 16
Setting the Initial Switch Configuration 1 Displaying the Fabric-Wide Device Count To verify that you have fabric-wide connectivity when you install a new switch, display the fabric-wide device count from the newly installed switch. To display the fabric-wide device count from a switch: 1. Login to the switch as the admin user. 2. At the command line, enter the following command: nsAllShow This command displays all the connected devices in the fabric. 1-6 Departmental Switch Model DS-16B2 Fabr
Inhaltszusammenfassung zur Seite Nr. 17
2 Invisible Body Tag Basic Switch Configuration Procedures This chapter provides the following information on basic configuration tasks for Departmental Switch Model DS-16B2 switch. Setting the Telnet Timeout Value .....................................................2-2 Displaying the Firmware Version....................................................2-2 Setting the Switch Date and Time....................................................2-3 Displaying the System Configuration Se
Inhaltszusammenfassung zur Seite Nr. 18
Basic Switch Configuration Procedures 2 Setting the Telnet Timeout Value To set a new Telnet timeout value: 1. Log in to the switch as the admin user. 2. At the command line, enter the following command: timeout x where x is the number of minutes before the Telnet connection times out. If you specify 0, then the connection never times out. Timeout is disabled by default. Displaying the Firmware Version To display the firmware version: 1. Log in to the switch as the admin user. 2. At the comman
Inhaltszusammenfassung zur Seite Nr. 19
Basic Switch Configuration Procedures 2 Setting the Switch Date and Time All switches maintain current date and time in nonvolatile memory. Date and time are used for logging events. Switch operation does not depend on the date and time; a switch with an incorrect date and time value still functions properly. To set the date and time of a switch: 1. Log in to the switch as the admin user. 2. At the command line, enter the following command: date "MMDDhhmmYY" where: MM is the month, valid val
Inhaltszusammenfassung zur Seite Nr. 20
Basic Switch Configuration Procedures 2 Displaying the System Configuration Settings To display the system configuration settings: 1. Login to the switch as the admin user. 2. At the command line, enter the following command: configShow The system configuration settings displays. For more information on the system configuration settings, refer to the Departmental Switch Model DS-16B2 Fabric OS Reference Manual. Backing Up the System Configuration Settings Currently, only the RSHD.EXE and CAT.E