Inhaltszusammenfassung zur Seite Nr. 1
SMALL OFFICE
REMOTE ACCESS SWITCH
EXAMPLE NETWORKS
Release 7.2
Cabletron Systems
(603) 332-9400 phone
(603) 337-3075 fax
support@ctron.com
Inhaltszusammenfassung zur Seite Nr. 2
EXAMPLE NETWORKS Only qualified personnel should perform installation procedures. ! CAUTION NOTICE You may post this document on a network server for public use as long as no modifications are made to the document. Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or soft
Inhaltszusammenfassung zur Seite Nr. 3
TRADEMARKS Cabletron Systems, CyberSWITCH, MMAC-Plus, SmartSWITCH, SPECTRUM, and SecureFast Virtual Remote Access Manager are trademarks of Cabletron Systems, Inc. All other product names mentioned in this manual are trademarks or registered trademarks of their respective companies. COPYRIGHTS All of the code for this product is copyrighted by Cabletron Systems, Inc. © Copyright 1991-1997 Cabletron Systems, Inc. All rights reserved. Printed in the United States of America. Portions of the code
Inhaltszusammenfassung zur Seite Nr. 4
EXAMPLE NETWORKS WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limit
Inhaltszusammenfassung zur Seite Nr. 5
CONTENTS Simple Remote Bridging Network 9 Overview 9 Initial Installation Steps 9 Configuring the Simple Remote Bridge 9 Resources 10 Lines 10 Bridging and Routing Information 11 Bridging 11 IP Routing 11 Configure the CyberSWITCH 12 Save Configuration Files 15 Verify the Installation 16 Remote Bridging Network with Security 17 Overview 17 Initial Installation Steps 17 Resources 19 Lines 19 Device Information 20 Bridging and
Inhaltszusammenfassung zur Seite Nr. 6
EXAMPLE NETWORKS IP Routing Network with Remote Bridge Devices 45 Overview 45 Business Assumptions 45 Initial Installation Steps 45 Resources 47 Lines 47 Device Information 48 Bridging and Routing Information 50 Bridging 50 IP Routing 50 Configure the CyberSWITCH 51 Configuring the CyberSWITCH Options 51 Configuring the Security 54 Verify the Installation 57 IP Routing Network with PPP Devices 58 Overview 58 Initial Installation Ste
Inhaltszusammenfassung zur Seite Nr. 7
Configure IPX Routing: Masternet (Detroit) 85 Configure Devices 85 Configure System Options 87 Save Configuration Files 92 Configure the Remote Devices 92 Verify the Installation 92 AppleTalk Routing Network 93 Overview 93 Initial Installation Steps 93 Resources 95 Lines 95 AppleTalk Routing 96 Configure the CyberSWITCH 98 Configuring the Options 98 Configuring Device Information 101 Configuring an AppleTalk Static Route 104 Save C
Inhaltszusammenfassung zur Seite Nr. 8
EXAMPLE NETWORKS We provide several example networks, beginning with a simple network and progressing to more complex networks. You may find the configuration instructions provided for each example helpful when configuring your own network. We include the following chapters: • Simple Remote Bridging Network An example of a simple network using remote bridge devices to access a CyberSWITCH’s four basic rate lines. • Remote Bridging Network with Security A bridged network with Calling Line Id
Inhaltszusammenfassung zur Seite Nr. 9
SIMPLE REMOTE BRIDGING NETWORK OVERVIEW This chapter provides an example of a simple network using remote bridge devices to access four basic rate lines in the CyberSWITCH. Bridges are formed between each of the LANs to which the remote bridge devices are connected, and the LAN to which the CyberSWITCH is connected. The following section provides the initial installation steps that would be used with any type of network installation. INITIAL INSTALLATION STEPS The initial steps in the Cybe
Inhaltszusammenfassung zur Seite Nr. 10
EXAMPLE NETWORKS SYSTEM DETAILS System Name: SITE1 PAP Password:_______________ CHAP Secret:___________________ RESOURCES Type Slot Switch type Synchronization type BRI 1 5ESS Ethernet_1 2 LINES BRI Lines Name Slot Port Line type Call screen TEI SPID Directory number Line1 1 1 PPP Auto PRI Lines Name Slot Port Framing type Line coding Sig. method Line build-out V.35 and RS232 Lines Name Slot Port Device/Network Idle character 10 CyberSWITCH
Inhaltszusammenfassung zur Seite Nr. 11
SIMPLE REMOTE BRIDGING NETWORK Bridging and Routing Information BRIDGING AND ROUTING INFORMATION BRIDGING Bridging X enabled ❒ disabled Mode of Operation ❒ restricted ❒ unrestricted Bridge Filters Bridge Dial Out/ Known Connect List IP ROUTING IP Routing X enabled ❒ disabled Mode of Operation ❒ router X IP host Network Interface Information LAN Name IP address Mask Unnumbered WAN ❒ need ❒ don’t need Remote LAN Name IP address Mask Traditional WAN Name I
Inhaltszusammenfassung zur Seite Nr. 12
EXAMPLE NETWORKS CONFIGURE THE CYBERSWITCH Using CFGEDIT, we will guide you through the steps to configure the CyberSWITCH for a simple remote bridge network. We will execute these steps in the same order as they appear in the configuration menus. Start the CFGEDIT configuration utility. Type the following command at the system prompt: cfgedit The following Main Menu will then be displayed: Main Menu: 1) Physical Resources 2) Options 3) Security 4) Save Changes Select fun
Inhaltszusammenfassung zur Seite Nr. 13
SIMPLE REMOTE BRIDGING NETWORK Bridging and Routing Information LINE TYPE = BR_ISDN 1) POINT_TO_POINT 2) POINT_MULTIPOINT Select Option [default = POINT_TO_POINT] or press for previous menu: 1 The next item that you need to configure is the Data Link for the line.
Inhaltszusammenfassung zur Seite Nr. 14
EXAMPLE NETWORKS CSX150 "SITE1" ISDN IP Host Interface 192.42.1.0 192.42.1.6 CSX150 "SITE2" IP Host Interface 192.42.1.7 Telnet Client The network illustrated above is a bridged network. Each system, SITE1 and SITE2 have been configured with all the necessary bridging information. SITE1 and SITE2 have also been configured in the IP host operating mode, and each have an IP host interface. This will allow each system to be managed remotely by the PC using Telnet client software (once the initia
Inhaltszusammenfassung zur Seite Nr. 15
SIMPLE REMOTE BRIDGING NETWORK Bridging and Routing Information To configure the IP host interface: 1. Select IP Interfaces from the IP configuration menu. 2. Select to add an interface. 3. Enter the IP address assigned to this interface. For SITE1, this is 192.42.1.6; for SITE2, this is 192.42.1.7. 4. Enter the subnet mask. 5. Enter the MTU size. 6. Select the transmit broadcast address. If IP RIP is enabled, enter the following additional information: 7. IP RIP receive control. 8. IP RIP resp
Inhaltszusammenfassung zur Seite Nr. 16
EXAMPLE NETWORKS VERIFY THE INSTALLATION Steps on how to verify the installation are detailed in the System Verification chapter of the User’s Guide. This section gives an outline of which steps should be executed. On the CyberSWITCH: Verify resources are operational Issue dr command Look for BRI line messages Look for LAN initialized messages Look for Bridge initialized messages Verify WAN Lines Available Connect WAN lines Issue dr command Look for “Data Link up 1,1” in reports On each Combi
Inhaltszusammenfassung zur Seite Nr. 17
REMOTE BRIDGING NETWORK WITH SECURITY OVERVIEW This example network is a bridged network with Calling Line Id security and Bridge MAC Address security enabled. The network is configured with two devices. One device will be configured to require a Bridge MAC Address security password, and one device will not. This network uses BRI lines. Worksheets for this network are included on the following pages. Note that a Hunt Group is used for the BRI lines pictured in the Network Topology Worksheet.
Inhaltszusammenfassung zur Seite Nr. 18
EXAMPLE NETWORKS NETWORK TOPOLOGY File Server PC CSX150 Hunt Group Number: 13135551111 13135551111 BRI 13135551112 ISDN 13135551212 13135556789 BRI BRI 13135552121 13135559876 Bridge Ethernet Address: Bridge Ethernet Address: 000123456789 003456789000 Password: JXF30 Password: None User Name: User Name: Mike Mann Pat Smith PC PC 18 CyberSWITCH
Inhaltszusammenfassung zur Seite Nr. 19
REMOTE BRIDGING NETWORK WITH SECURITY Initial Installation Steps SYSTEM DETAILS System Name: Remote Bridge PAP Password:_______________ CHAP Secret:___________________ RESOURCES Type Slot Switch type Synchronization type BRI 1 NI-1 Ethernet_1 2 LINES BRI Lines Name Slot Port Line type Call TEI SPID Directory screen number Line1 1 1 PPP Auto 3135551111 13135551111* 3135551112 13135551112* * Hunt Group Number: 13135551111 Small Office Remote Access Switch 19
Inhaltszusammenfassung zur Seite Nr. 20
EXAMPLE NETWORKS DEVICE INFORMATION Device Name: Mike Mann Calling (ISDN, FR, etc.) Information X.25 Information Line Protocol HDLC bridge PVC Base Data Rate SVC Initial Data Rate Max Data Rate Dial-Out Number(s) Authentication Information: Frame Relay Information PAP Password DLCI CHAP Secret IP Host ID Bridge Ethernet Address* 000123456789 Bridge Password* JXF30 CLID(s) 13135551212 13135552121 * HDLC Bridge only Protocol for this particular device? Bridge