Inhaltszusammenfassung zur Seite Nr. 1
PA Amplifiers
iNUKE NU6000DSP
NU3000DSP/NU1000DSP
NU6000/NU3000/NU1000
iNUKE NU6000DSP—
Ultra-Lightweight, High-Density
6000-Watt Power Amplifier with
DSP Control and USB Interface
Delivers 2 x 3000 Watts into 4 Ohms, iNUKE Series power amplifiers When this amazing amplifier
2 x 1500 Watts into 8 Ohms and pack massive amounts of technology is combined with our
weighs less than 12 lbs / 5.5 kg output power into exceptionally state-of-the-art switching-mode power
lightweight, rack-mountable
Inhaltszusammenfassung zur Seite Nr. 2
Page 2 of 11 The rear panel is just as elegant, iNUKE DSP iNUKE NU6000DSP with combo XLR and 1/4" TRS input For sound engineers requiring connectors making the iNUKE compatible NU3000DSP high-level control capability, iNUKE DSP with virtually any source, balanced or Series amplifiers come ready for action unbalanced. Professional twist-lock NU1000DSP right out-of-the-box. The built-in DSP speaker sockets are provided to ensure and 24-bit/96 kHz converters ensure the NU6000 every drop
Inhaltszusammenfassung zur Seite Nr. 3
Page 3 of 11 Value all the amenities a professional audio iNUKE NU6000DSP engineer could ask for, BEHRINGER iNUKE Sporting massive output ratings, amplifiers are serious amps for the most NU3000DSP lightweight Class-D technology, demanding applications. an equally lightweight price tag, and NU1000DSP NU6000 NU3000 iNUKE NU6000DSP/NU3000DSP/NU1000DSP NU1000 Front Panel DSP LCD panel with parameter controls iNUKE NU6000— USB socket for laptop allows setup without Ultra-Lightweight, High-
Inhaltszusammenfassung zur Seite Nr. 4
Page 4 of 11 iNUKE NU6000DSP NU3000DSP System configuration is a breeze thanks NU1000DSP to iNUKE’s Amp Remote software (Available on iNUKE DSP models only) NU6000 NU3000 NU1000 Built-in Subwoofer/Satellite crossover for perfect Dynamic EQ combines the effects subwoofer operation of equalization and side-chain compression to compensate Detented and illuminated gain for the perceived loudness controls for precise level setting of specific frequency ranges Precise 4-segment Signal
Inhaltszusammenfassung zur Seite Nr. 5
Page 5 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 iNUKE NU3000 – Live Setup with PA and Floor Monitor UMA25S ULTRACOUSTIC ACX900 XM8500 Vocal Mics Tape In Tape Out Portable Multi-track Mon out Recorder XENYX X1222USB EUROLIVE F1320D L Main out R Active Floor Monitor iNUKE NU3000 B215XL Passive Loudspeakers
Inhaltszusammenfassung zur Seite Nr. 6
Page 6 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Concert Setup with Delay Line VP1520 Right delay line iNUKE NU3000DSP Group 2 Out FOH (Front Of House) loudspeaker system Main A Out XENYX XL3200 Group 1 Out iNUKE NU3000DSP Left delay line VP1520
Inhaltszusammenfassung zur Seite Nr. 7
Page 7 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 iNUKE NU1000 – Live Stereo DJ Setup with Passive PA iNUKE NU1000 B-CONTROL DEEJAY HPX2000 BCD3000 B1800X PRO Passive Subwoofer VP1520 Passive Loudspeaker XM8500 Talkover Mic Turntables
Inhaltszusammenfassung zur Seite Nr. 8
Page 8 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Specifications NU6000DSP NU3000DSP Connectors Output Power Output Power Inputs 2 x combo jacks Maximum output power Maximum output power Input impedance 10 kΩ unbalanced, Stereo Stereo 20 kΩ balanced 8 Ω per channel, stereo 1500 W 8 Ω per channel, stereo 440 W Outputs 2 x locking-style professional 4 Ω per channel, stereo 3000 W s p e ak e r c o n n e c t o r s 4 Ω per channel, stereo 820 W 2 Ω per channel, stereo — Ou
Inhaltszusammenfassung zur Seite Nr. 9
Page 9 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 NU1000DSP Connectors Connectors Output Power Inputs 2 x combo jacks Inputs 2 x combo jacks Maximum Output Power Input impedance 10 kΩ unbalanced, Input impedance 10 kΩ unbalanced, Stereo 20 kΩ balanced 20 kΩ balanced 8 Ω per channel, stereo 160 W Outputs 2 x locking-style professional Outputs 2 x locking-style professional 4 Ω per channel, stereo 320 W speaker connectors speaker connectors 2 Ω per channel, stereo
Inhaltszusammenfassung zur Seite Nr. 10
Page 10 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 NU6000 Output Power System Amplifier protection Thermal and DC protection Maximum Output Power Stable into reactive or Controls mis m a t c h e d l o a d s Stereo Front Power switch Load protection On/off muting, DC-fault power Gain controls (channels A and B) 8 Ω per channel, stereo 1500 W su p p l y s hu td o w n Rear Mode switch 4 Ω per channel, stereo 3000 W (bridge/stereo/mono) 2 Ω per channel, stereo — Cro
Inhaltszusammenfassung zur Seite Nr. 11
Page 11 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 NU1000 Output Power Power Supply, Voltage (Breaker/Fuse) Indicators Maximum Output Power Power Amber/red backlit illuminated USA / Canada 120 V~, 60 Hz (T 6.3 A H 250 V) gai n c o n t r o l s Stereo UK / Australia / Europe 220-240 V~, 50/60 Hz Limit (per channel) 0 dB, full scale (T 3.15 A H 250 V) 8 Ω per channel, stereo 150 W Signal (per channel) -24, -12, -6 dB Korea / China 220-240 V~, 50/60 Hz 4 Ω per channel, st