Inhaltszusammenfassung zur Seite Nr. 1
User Manual
EUROPOWER
EP2000/EP4000
Professional 2,000 and 4,000-Watt Stereo Power Amplifier
with ATR (Accelerated Transient Response) Technology
behringer.com
Inhaltszusammenfassung zur Seite Nr. 2
2 EUROPOWER EP2000/EP4000 User Manual Table of Contents Thank you ....................................................................... 2 Important Safety Instructions ...................................... 3 Legal Disclaimer ............................................................. 3 Limited Warranty ........................................................... 3 1. Introduction ............................................................... 5 1.1 Before you get started ..................
Inhaltszusammenfassung zur Seite Nr. 3
3 EUROPOWER EP2000/EP4000 User Manual 9. Do not defeat the safety purpose of the polarized Limited Warranty Limited Warranty Important Safety Important Safety or grounding-type plug. A polarized plug has two blades Instructions Instructions § 1 Warranty with one wider than the other. A grounding-type plug [1] This limited warranty is valid only if you purchased has two blades and a third grounding prong. The wide the product from a BEHRINGER authorized dealer in the blade or the third pro
Inhaltszusammenfassung zur Seite Nr. 4
4 EUROPOWER EP2000/EP4000 User Manual [2] Subsequently, the product must be returned in [7] Any repair or opening of the unit carried out by § 9 Amendment its original shipping carton, together with the return unauthorized personnel (user included) will void the Warranty service conditions are subject to change without authorization number to the address indicated by limited warranty. notice. For the latest warranty terms and conditions MUSIC Group. [8] If an inspection of the product b
Inhaltszusammenfassung zur Seite Nr. 5
5 EUROPOWER EP2000/EP4000 User Manual 1. Introduction ◊ Please make sure that all units have a proper ground connection. For your own safety, never remove or disable the ground conductor Honestly, who really likes to read manuals? We know you want to get started from the unit or the AC power cord. right away, but please read this manual carefully and keep it for future reference. It is only after reading these instructions that you will fully understand and be ◊ The sound quality may dimini
Inhaltszusammenfassung zur Seite Nr. 6
6 EUROPOWER EP2000/EP4000 User Manual 2.2 Rear panel [7] [8] [11] [12] [13] [14] [9] [10] [16] [15] Fig. 2.2: Rear panel control elements [7] These are the balanced XlR inputs (channels 1 and 2). 2.3 Configuration switches (MODE SWITCHES) [8] These are the stereo ¼" tRs inputs (channels 1 and 2). They can also be used with unbalanced plugs. [9] These are the moDe switches, used to alter the operating modes as well as to set the limiters and high-pass filters (see chapter 2.3). [10] The u
Inhaltszusammenfassung zur Seite Nr. 7
7 EUROPOWER EP2000/EP4000 User Manual The 50 Hz filter should be engaged when using broadband speakers because 3. Applications the filter provides a moderate amplification in the 100-Hz range, resulting in ◊ Running EUROPOWER amplifiers in conjunction with 8-Ohm speakers a fuller sound. The 30 Hz filter is ideally suited for subwoofer operation as well with a power rating of at least 2 x 400 Watts (EP2000) and 2 x 750 Watts as for broadband cabinets. The “Off” setting should be used only fo
Inhaltszusammenfassung zur Seite Nr. 8
8 EUROPOWER EP2000/EP4000 User Manual Fig. 3.2: DIP switch positions for 2-channel operation Fig. 3.4: DIP switch positions for parallel operation Parallel mode is identical to 2-channel mode, except for the inputs of both When running in mono-bridged mode, the voltage of both channels is added channels are internally connected in parallel. One input signal routes parallel up and fed into a single loudspeaker system. There is one input and one output both channels, while their filters etc. are
Inhaltszusammenfassung zur Seite Nr. 9
9 EUROPOWER EP2000/EP4000 User Manual The BEHRINGER EUROLIVE SERIES loudspeakers are an outstanding solution for expanding your P.A. system, because each frequency range/application has a speaker type that optimally suits its characteristics. ◊ Extreme clip limiter settings in bi-amp operating mode can result in balance shifting. XENYX 2222FX Mixing Console Fig. 3.6: DIP switch positions for mono-bridged mode ◊ When the amp is overdriven for longer periods of time, the output signal may occa
Inhaltszusammenfassung zur Seite Nr. 10
10 EUROPOWER EP2000/EP4000 User Manual 4. Installation 4.1.1 Using the binding posts Your EUROPOWER can be installed into a 19" rack and requires two rack units. To connect the loudspeakers to the amplifier’s binding posts, please do Please use four attaching screws and washers for installation. Reinforce the back the following: end, especially for on-the-road use. Please assure that enough cool air reaches 1) Switch off the amp and disconnect it from the mains the rack, especially when ot
Inhaltszusammenfassung zur Seite Nr. 11
11 EUROPOWER EP2000/EP4000 User Manual 4.2 Audio connections Various cables are needed for different types of applications. The following Balanced ¼" TRS connector illustrations show the correct wiring. Always use high-grade cables. strain relief clamp When connecting a balanced input signal, please make sure to exclusively sleeve use balanced cables for passing the signal further on. Otherwise, one single ring unbalanced cable can turn the entire signal unbalanced. tip Balanced use with XLR
Inhaltszusammenfassung zur Seite Nr. 12
12 EUROPOWER EP2000/EP4000 User Manual 5. Specifications output Power Distortion RMS @ 1% THD (sine wave), both channels driven EP2000 < 0.01% EP2000 EP4000 < 0.02% 8 p Ω er channel 350 W Frequency Response 4 Ω per channel 500 W at 10 dB below rated output power 20 Hz - 20 kHz, +0/-1 dB 2 p Ω er channel 650 W at -3 dB points 5 Hz - 50 kHz EP4000 Damping Factor 8 Ω per channel 550 W EP2000/EP4000 > 300 @ 8 Ω 4 Ω per channel 950 W 2 Ω per channel 1250 W noise RMS @ 1% THD (sine wave), bridged m
Inhaltszusammenfassung zur Seite Nr. 13
13 EUROPOWER EP2000/EP4000 User Manual l oad Protection EP2000/EP4000 Turn-on/off muting, AC coupling output c ircuit type EP2000 Class AB complementary linear output EP4000 Class H complementary linear output Power supply Mains voltage/Breaker 100 - 120 V~, 50/60 Hz 15 A 220 - 230 V~, 50/60 Hz 8 A Power consumption EP2000 1600 W EP4000 2600 W Mains connector Standard IEC receptacle Dimensions/weight Dimensions (H x W x D) EP2000/EP4000 approx. 3.5 x 19 x 15.8" approx. 88 x 483 x 402 mm We
Inhaltszusammenfassung zur Seite Nr. 14
14 EUROPOWER EP2000/EP4000 User Manual behringer.com
Inhaltszusammenfassung zur Seite Nr. 15
15 EUROPOWER EP2000/EP4000 User Manual behringer.com
Inhaltszusammenfassung zur Seite Nr. 16
behringer.com