Inhaltszusammenfassung zur Seite Nr. 1
ENGLISH ESPAÑOL
website http://www.lgappliances.com
LG
LG
ROOM AIR CONDITIONER
OWNER'S MANUAL
Please read the operating instructions and safety precautions carefully
and thoroughly before installing and operating your room air conditioner.
ACONDICIONADOR DE AIRE DE VENTANA
MANUAL DEL PROPIETARIO
Por favor lea las instrucciones de operación y las precauciones de
seguridad cuidadosa y totalmente antes de instalar y operar su
acondicionador de aire de ventana.
MODELS, MODELOS: LT1230CR
IMPORTANT
P
Inhaltszusammenfassung zur Seite Nr. 2
Window-Type Air Conditioner Owner’s Manual TABLE OF CONTENTS Safety Precautions..........................3 FOR YOUR RECORDS Write the model and serial numbers here: Before Operation.............................7 Model # Serial # You can find them on a label on the side of each unit. Introduction ....................................8 Dealer's Name Date Purchased Electrical Safety ..............................9 Staple your receipt to this page in the event you need it to prove date of purchase
Inhaltszusammenfassung zur Seite Nr. 3
ENGLISH Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. WARNING This symbol indicates the possibility of injury or damage to properties only. CAUTION Meanings of symbols used in this manual are
Inhaltszusammenfassung zur Seite Nr. 4
Safety Precautions Operation Do not place heavy object Do not share the outlet with Take the power plug out if on the power cord and take other appliances. necessary, holding the head care so that the cord should of the plug and do not touch not be pressed. it with wet hands. • There is danger of fire or electric • It will cause electric shock or fire • Otherwise, it may cause a fire shock. due to heat generation. or electrical shock. Do not place the power cord Do not allow water to run Use a
Inhaltszusammenfassung zur Seite Nr. 5
ENGLISH Safety Precautions Do not operate or stop the Do not damage or use an Do not operate with wet unit by inserting or pulling unspecified power cord. hands or in damp out the power plug. environment. • It will cause electric shock or fire • It will cause electric shock or fire. • It will cause electric shock. due to heat generation. Hold the plug by the head When gas leaks, open the Never touch the metal parts when taking it out. window for ventilation of the unit when removing before opera
Inhaltszusammenfassung zur Seite Nr. 6
Safety Precautions Operation Do not put a pet or house Do not block the inlet or Useasoftclothtoclean.Do plant where it will be outlet of air flow. not use wax, thinner, or a exposedtodirectairflow. strong detergent. • It may cause injury. • It may cause product failure. • The appearance of the air conditioner may deteriorate, change color, or develop surface flaws. Do not step on the Always insert the filter Do not drink water drained indoor/outdoor unit and do securely. from air conditioner.
Inhaltszusammenfassung zur Seite Nr. 7
ENGLISH Before Operation Before Operation Preparing for Operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Use a dedicated circuit. 4. Do not use an extension cord. 5. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, replace it with only an authorized replacement part. Usage 1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occup
Inhaltszusammenfassung zur Seite Nr. 8
Introduction Introduction Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. This symbol indicates special notes. NOTICE Features This appliance should be installed in accordance with the National Electric Code. THE SLEEVE AND THE REAR GRILLE (optionally supplied with your unit) SLEEVE ASSEMBLY (Including Aluminum Rear grille) REAR GRILLE (Aluminum Rear grille) THE UNIT VERTICAL AIR DEF
Inhaltszusammenfassung zur Seite Nr. 9
ENGLISH Electrical Safety Electrical Safety Electrical Data 115V~ 230V~ Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. NOTICE The shape may be different accordi
Inhaltszusammenfassung zur Seite Nr. 10
Electrical Safety Electrical Safety A. SITUATIONS WHEN THE APPLIANCE WILL BE IMPORTANT DISCONNECTED OCCASIONALLY: (PLEASE READ CAREFULLY) Because of potential safety hazards, we strongly FOR THE USER'S PERSONAL SAFETY, THIS discourage the use of an adapter plug. However, if you APPLIANCE MUST BE PROPERLY GROUNDED wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, The power cord of this appliance is equipped with a available from most local hardware stores. three-p
Inhaltszusammenfassung zur Seite Nr. 11
ENGLISH Installation Installation Remove packing materials from the wall sleeve and tape INSTALLATION HARDWARE from the air conditioner. 2 4 1 INSTALLATION REQUIREMENTS 5 If you use an existing wall sleeve, you should measure its dimensions. 2 Size options Install the new air conditioner according to these 6 installation instructions to achieve the best 8 10 performance. All wall sleeves used to mount the new air conditioner must be in good structural condition 3 9 and have a rear grille to secu
Inhaltszusammenfassung zur Seite Nr. 12
Installation INSTALLATION NOTICE All wall sleeves used to mount the new Air Conditioner must be in sound structural condition We strongly recommend the removal of the and have a rear grille that securely attaches to old wall sleeve and the installation of a new sleeve, or rear flange that serves as a stop for the LGE Wall Sleeve. Air Conditioner. If you decide to keep the existing wall sleeve, Remove old air conditioner from existing wall 2 you have to redirect the louvers at the back of sleeve.
Inhaltszusammenfassung zur Seite Nr. 13
ENGLISH Installation PROCEDURE A Ifyouareusingthenewsleeve(optionally Install the new unit into the wall sleeve. 1 4 supplied with your unit),skip to step 3. Otherwise, install the plastic grille from the kit. To assemble trim, snap the tab of each piece 5 Cut the plastic grille to 25-1/2" wide and 15- into the slot of the other piece as shown below. 1/4" high. Place the plastic grille to the inside Slide trim over the front of the air conditioner of the wall sleeve at the rear flange. until tri
Inhaltszusammenfassung zur Seite Nr. 14
Installation Remove the backing from the Vertical Insulation PROCEDURE B 4 9 3 3 strip 15 / x1 / x1 / and attach that to the 16 8 8 Redirect the louvers at the back of the wall inside right of the sleeve as shown below. 1 sleeve to 60° angle as shown in the FIG 8. The Remove the backing from the Around Insulation 1 3 25 use of pliers is recommended. strip 67 / x1 / x / and attach that to the 8 8 32 inside front of the sleeve as shown below. 3 7 / " 32 60° Indoor Outdoor 60° Rear Louvers Around I
Inhaltszusammenfassung zur Seite Nr. 15
ENGLISH Installation PROCEDURE B Remove the backing from the support blocks 6 and attach them to the inside of the wall sleeve as shown FIG 13. Slide the baffle into slots of the support blocks. 3 (7 /32") Wall Wall Baffle Sleeve Front Support Block FIG. 13 Install the new unit into the wall sleeve. 7 Assemble trim as described in Step 5, 8 Procedure A. CAUTION • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. T
Inhaltszusammenfassung zur Seite Nr. 16
Installation Remove the backing from the Horizontal PROCEDURE C 4 7 3 3 Insulation strip 23 / x1 / x1 / and attach 32 8 16 Redirect the louvers at the back of the wall that to the inside right of the sleeve as shown 1 sleeve to 60° angle as shown in the FIG 14. below. Remove the backing from the Around 27 3 3 The use of pliers is recommended. Insulation strip 59 / x1 / x1 / and attach 32 8 8 thattotheinsidefrontof thesleeveasshown 3 7 /32" below. 60° 60° Rear Louvers Indoor Outdoor (Top View) Ar
Inhaltszusammenfassung zur Seite Nr. 17
ENGLISH Installation PROCEDURE C To achieve rearward slope for unit draining, 7 13 • Air conditioners covered in this manual pose an remove the backing from the 11 / "shim 16 excessive weight hazard. Two or more people are strips and attach them as shown below in Fig. needed to move and install the unit. 21. The higher portion of shim is to be placed To prevent injury or strain, use proper lifting and in front of the rib on the base of wall sleeve. carrying techniques when moving unit. • When ha
Inhaltszusammenfassung zur Seite Nr. 18
Operating Instructions Operating Instructions Controls The controls will look like one of the following. FAN SPEED • Every time you push this button, it advances the setting as follows: {High Low Med High} REMOTE CONTROL SIGNAL RECEIVER ' Cool F F1 LOW F2 MED Energy F3 HIGH Saver TEMPERATURE SETTING • Use this button to automatically control the Fan temperature of the room. TEMP Timer The temperature can be set within a range of 60°F to 86°F by increments of 1°F. FAN • The setting app
Inhaltszusammenfassung zur Seite Nr. 19
ENGLISH Operating Instructions Remote control The remote control and control panel will look like one of the following pictures. POWER • To turn the air conditioner ON, push this button. To turn the air conditioner OFF, push the button again. • This button takes priority over any other button. • When you first turn it on, the unit is in cool mode, High fan speed, Power Temperature setting at 72°F. • Auto Restart In the event at a power failure, the unit will run at the previous setting once p
Inhaltszusammenfassung zur Seite Nr. 20
Operating Instructions How to insert Batteries 1. Remove the cover from the back of the remote • Do not use rechargeable batteries. controller. Such batteries differ from standard dry cells in shape, dimensions, and 2. Insert two batteries. performance. • Be sure that the (+) and (-) directions are • Remove the batteries from the correct. remote controller if the air • Be sure that both batteries are new. conditioner is not going to be used for an extended length of time. 3. Re-attach the cover.