Inhaltszusammenfassung zur Seite Nr. 1
SIGNAL PROCESSING UNIT
PFV-SP3300
BACKUP POWER SUPPLY UNIT
HK-PSU03
INSTALLATION MANUAL
1st Edition
Serial No. 10001 and Higher (PFV-SP3300)
Serial No. 10001 and Higher (HK-PSU03)
Inhaltszusammenfassung zur Seite Nr. 2
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. ! WARNUNG Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt. Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden. Um die Gefahr eines elektrischen Schlages, F
Inhaltszusammenfassung zur Seite Nr. 3
Table of Contents Manual Structure Purpose of this manual ........................................................................................ 2 (E) Related manuals................................................................................................... 2 (E) 1. Installation 1-1. Operating Environment .........................................................................1-1 (E) 1-2. Power Supply ....................................................................................
Inhaltszusammenfassung zur Seite Nr. 4
Manual Structure Purpose of this manual This manual is the installation manual of Signal Processing Unit PFV-SP3300 and its Backup Power Supply Unit HK-PSU03. This manual is intended for use by trained system and service engineers, and describes the information for installation of the unit. n The functions and specifications of HK-PSU03 and PFV-SP3300’s power supply unit are equal. This manual uses “Power Supply Unit” for HK-PSU03 and PFV- SP3300’s power supply unit. Related manuals The followin
Inhaltszusammenfassung zur Seite Nr. 5
Section 1 Installation 1-1. Operating Environment 1-2. Power Supply Operating temperature +5 dC to +40 dC 1-2-1. Power Supply Specifications Performance temperature +10 dC to +35 dC Humidity 10 to 90 % (No condensation) Power voltage AC 100 V to 240 V Mass: PFV-SP3300 Approx. 10 kg Power frequency 50 Hz or 60 Hz (Without the optional unit and Current consumption 3.5 to 1.5 A board) Rush current AC 100 V IN : 15 A HK-PSU03 Approx. 2 kg AC 240 V IN : 55 A . To prevent overheating of PFV-SP3300, en
Inhaltszusammenfassung zur Seite Nr. 6
1-3. Installation Space 1-3. Installation Space m . Do not block the ventilation holes of the unit. . Both of the front and rear sides must be at least 20 cm away from the walls for ventilation and mainte- nance. The outer dimensions of PFV-SP3300 are as shown here: 440 17.5 132.4 375 482 Unit: mm PFV-SP3300 1-2 (E) 61 380 ø26 26 550 7
Inhaltszusammenfassung zur Seite Nr. 7
1-4. Installing/Removing Optional Power Supply Unit 1-4. Installing/Removing Optional Power 3. Make sure that the power switch of the backup power Supply Unit supply unit HK-PSU03 is set to the “O” position (OFF). w 4. Insert HK-PSU03 into PFV-SP3300 and push it by Before installing the backup power supply unit HK-PSU03 hand as far as it will go. in PFV-SP3300, set the power switch of HK-PSU03 to the 5. Secure HK-PSU03 with the two screws which is “O” position (OFF). removed in step 2. Otherwise
Inhaltszusammenfassung zur Seite Nr. 8
1-5. Installing Optional Board 1-5. Installing Optional Board 4. Insert the main board fully into the slot along the board guides and close the board lever in the direction The optional board can be installed in any empty slot of indicated by arrow 1. PFV-SP3300. 5. Stick the slot label supplied with the PFV-SP3300 onto the board lever. n Installing Main Board (Front side) Attach the supplied slot label to the position shown in 1. Turn off the power switches of PFV-SP3300. the figure. n Do not a
Inhaltszusammenfassung zur Seite Nr. 9
1-5. Installing Optional Board Installing Connector Panel (Rear side) The connector panel must be installed to the slot which contains the main board. 1. Remove the two screws and remove the blank panel of the slot which contains the main board. n Keep the removed blank panel and two screws. B 3x5 B 3x5 Blank panel 2. Connect the connector panel to the MB-915 board. 3. Secure the connector panel with the two screws. MB-915 board Screws Connector panel n Do not open the slot for an air-cooled eff
Inhaltszusammenfassung zur Seite Nr. 10
1-6. Rack Mounting 1-6. Rack Mounting n Install a ventilating fan in the rack to prevent the increase PFV-SP3300 can be mounted on a 19-inch standard rack in the temperature inside a rack when multiple units are put for use. in one rack. Mount PFV-SP3300 on the rack properly in the procedure below using a specified rack mounting kit. 1-6-2. Rack Mounting Procedure Specified rack mounting kit: RMM-10 n Explains the procedure for rack mounting by Rack Mount PFV-SP3300 may not be able to be mounted
Inhaltszusammenfassung zur Seite Nr. 11
1-6. Rack Mounting n 7. Fix the unit to the rack with the specified screws. The maximum depth of an adaptor is 750 mm. The minimum depth of an adaptor is 595 mm. 3. Firmly lay the right and left adaptors in the rack with the specified six screws. (Following figure is case of left side.) RMM-10 Front 31.75 B 4x10 3U B 5x12 Rear B 4x10 31.75 B 5x12 4. Fasten the length adjustment screws which are loosened in step 2. 5. Remove the front panel. (Refer to Section 1-4.) 6. Align the crook of the each
Inhaltszusammenfassung zur Seite Nr. 12
1-7. Matching Connector/Cable 1-8. Signal Inputs/Outputs 1-7. Matching Connector/Cable When external cables are connected to the connectors on the PFV-SP3300 rear panel, the hardware listed below (or the equivalent) must be used. PFV-SP3300 side connector Matching connector/cable Print on Connector type Connector type Sony Part Number REMOTE BNC, 75Z BNC, 75Z 1-569-370-12 REF IN A/B Belden 1694 coaxial cable – STATUS OUT D-sub Mini 15-pin, Female D-sub Mini 15-pin, Male – 1-8. Signal Inputs/Outp
Inhaltszusammenfassung zur Seite Nr. 13
Section 2 Service Overview 2-1. Cleaning the Filter 2-2. Periodic Replacement Parts to Be Recommended w Be sure to turn off the power switch and disconnect the The fan used on the rear panel of this unit is periodic power cord from the outlet before starting any work. replacement parts to be recommended. The life of the fan is approximately 50,000 hours. The life corresponds to c about five years and a half if the power is on all the time, . The temperature inside the unit increases if dust ad
Inhaltszusammenfassung zur Seite Nr. 14
Inhaltszusammenfassung zur Seite Nr. 15
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation. Le matériel contenu dans ce manuel consiste en informations qui sont la propriété de Sony Corporation. Sony Corporation interdit formell
Inhaltszusammenfassung zur Seite Nr. 16
Printed in Japan HK-PSU03 (SY) PFV-SP3300 (SY) J, E Sony Corporation 2000. 8 22 3-204-888-01 Communication System Solutions Network Company ©2000