Inhaltszusammenfassung zur Seite Nr. 1
Kandy
INTEGRATED
INTEGRATED
INTEGRATED
AMPLIFIER
AMPLIFIER
AMPLIFIER
USER MANUAL
ROKSAN AUDIO LIM I TED
6 NORTHFIELD INDUSTRIAL ESTATE
BERESFORD AVENUE ALPERTON
MIDDLESEX HA0 1NW ENGLAND
TEL. +44 (0)208 900 6801
+44 (0)208 900 6802
FAX. +44 (0)208 900 0734
w
Inhaltszusammenfassung zur Seite Nr. 2
INTRODUCTION Kandy Integrated Amplifier Congratulations on your purchase of the ROKSAN Kandy Integrated Amplifier. This Integrated Amplifier is designed and manufactured to the highest specification and rigorously tested to offer you many years of trouble- free pleasure. Your Kandy Integrated Amplifier is at the heart of your hi-fi system. Its correct installation, set-up and operation will have a profound influence on the sonic performance of the entire hi-fi installation. Please re
Inhaltszusammenfassung zur Seite Nr. 3
CAUTIONS Kandy Integrated Amplifier AC MAINS SUPPLY AC MAINS SUPPLY Your Kandy Integrated Amplifier is set to operate from a fixed supply voltage which is marked on a label next to the mains input plug. Before connecting the mains lead please check that your mains supply corresponds to this label as below: 230V Products ………………………………….Voltage Range: 220V – 240V 115V Products ………………………………….Voltage Range: 100V – 120V The mains lead supplied with this product has an IEC mains
Inhaltszusammenfassung zur Seite Nr. 4
INSTALLATION Kandy Integrated Amplifier ROKSAN Kandy Integrated Amplifier- Front Panel View ROKSAN Kandy Integrated Amplifier- Front Panel View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 REMOTE MODE CD TUNER VIDEO LINE 1 LINE 2 PHONO TAPE MODE INPUT ROKSAN TAPE PHONE VOLUME Integrated Amplifier KA-I MkIII 1. Mode Button 2. Input Button (Back) 3. Input Button (Forward) 4. Mode Indicator 5. CD Input Indicator 6. Tuner Input Indicator 7. Video Input
Inhaltszusammenfassung zur Seite Nr. 5
1. Preamp Output 2 (Multi-Amping or Subwoofer) 2. Preamp Output 1 (Multi-Amping or Subwoofer) 3. Tape Input (Playback) 4. Tape Output (Record) 5. Phono Input 6. Line 2 Input 7. Line 1 Input 8. Video Input 9. Tuner Input 10. CD Input 11. Right Speaker Output 12. Left Speaker Output 13. Voltage & Fuse Label 14. AC Mains Power Switch 15. AC Mains Input 16. AC Mains Fuseholder 17. Phono Input Grounding Terminal SETUP Kandy Integrated Amplifier CONNECTING MAINS POWER Pl
Inhaltszusammenfassung zur Seite Nr. 6
Carefully remove any overal sheath or split the figure 8 cable to a depth of about 75mm (3”). Carefully strip the insulation on each wire to a depth of about 12mm (1/2”) exposing the bare core. If the conductor is stranded, twist the strands together on each conductor. Unscrew the binding post. There is a cross-hole about 5mm from the panel end of the binding post. Insert the bared conductor through the hole and tighten the binding post securely making sure that there are no loose strands o
Inhaltszusammenfassung zur Seite Nr. 7
OPERATION Kandy Integrated Amplifier Please refer to the front and rear panel views on page 4 and the Remote Handset View on page 8. S SW WIIT TC CH HIIN NG G O ON N The Mains power switch (14) is located on the rear panel of the amplifier. This switch should be left ON for normal operation. If unattended for a long period, the Mains power should be switched OFF and the lead disconnected from the power supply. When switched ON from the rear panel, your Kandy Integrated Amplifier w
Inhaltszusammenfassung zur Seite Nr. 8
The Tape Monitor is an override. Pressing the TAPE Button (12) connects the output of your tape deck to the Kandy, overriding the selected input. However, the selected input is left connected to the recording input of your tape deck. If you have a suitable tape deck, this facility enables you to record a programme whilst monitoring its playback. When the TAPE Button is depressed, the TAPE Indicator light (11) glows and the selected source Indicator remains illuminated. The input selector r
Inhaltszusammenfassung zur Seite Nr. 9
K KN NO OW W Y YO OU UR R K KA AN ND DY Y • When you first power up from the Mains Switch on the rear panel, the amplifier goes into Standby and the MODE Indicator glows GREEN. • During Standby, the power stage of the amplifier is shut down to reduce power consumption and heat. • In normal operation when an external fault such as a short circuit on the loudspeaker leads is detected, the amplifier will go into standby and the speaker output and AC power relays will disconnect and the MO
Inhaltszusammenfassung zur Seite Nr. 10
GUARANTEE Kandy Integrated Amplifier There are no user-serviceable parts inside your Kandy Integrated Amplifier. If a fault should develop, refer any servicing to your appointed ROKSAN dealer, distributor or ROKSAN approved service agent. Your ROKSAN Kandy Integrated Amplifier is guaranteed against any defect in materials and workmanship for a period of two years from the date of purchase. This guarantee only becomes effective if the warranty card is validated by the ROKSAN retailer from
Inhaltszusammenfassung zur Seite Nr. 11
NOTES Kandy Integrated Amplifier Kandy Integrated Amplifier L.III Serial Number: ………………………… Purchase Date Year .……… Month …….. Day …….. ROKSAN Retailer Name: ………………………………… Location: ……………………………… Please keep a record for future reference ww w . ro ks an. c o . uk Roksan Audio ltd Kandy Integrated Amplifier User Manual CLASSIFICATION: General Use Version 3.