Inhaltszusammenfassung zur Seite Nr. 1
INSTRUCTION MANUAL
VSE-2300 &
VSE-2400 SERIES
Cylindrical
Environmental Camera Housings
About this manual
Before installing and using this unit, please read
this manual carefully. Be sure to keep it available for
later reference.
Inhaltszusammenfassung zur Seite Nr. 2
12. Power Lines - An outdoor system should not be located in the IMPORTANT SAFEGUARDS vicinity of overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits. 1. Read Instructions - All the safety and operating instructions When installing an outdoor system, extreme care should be taken should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should to keep from touching such power lines o
Inhaltszusammenfassung zur Seite Nr. 3
SAFETY PRECAUTIONS SICHERHEITSVORKEHRUNGEN VORSICHT: UM EINEN ELEKTRISCHEN CAUTION: TO REDUCE THE RISK OF SCHLAG ZU VERMEIDEN, ABDECKUNG ELECTRICAL SHOCK, DO NOT OPEN COVERS. NICHT ENTFERNEN. WARTUNGEN ALLER NO USER SERVICEABLE PARTS INSIDE. REFER ART QUALIFIZIERTEM PERSONAL SERVICING TO QUALIFIED SERVICE ÜBERLASSEN. PERSONNEL. This label may appear on the bottom of the unit due to space Aus Platzgründen kann diese Warnung auf der Unterseite des limitations. Gerätes angebracht sein. The lightni
Inhaltszusammenfassung zur Seite Nr. 4
CONTENTS 1 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3 CARE AND MAINTENANCE . . . . . . . . . . . . . . . .4 4DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 5 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 6 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . .6 6.2 Maximum Camera/Lens Size . . . . . . . . . . . . . . . . . .5 6.1 Too
Inhaltszusammenfassung zur Seite Nr. 5
ELECTRICAL SPECIFICATIONS Camera Mounting: Removable camera bracket. Mounted Preinstalled Heater or Model Number Voltage/Power (V/W) 1 Heater/Blower with two screws. VSE-2300 --- Construction: Aluminum cover, aluminum base, aluminum VSE-2300H Heater 24/23 mounting foot, polycarbonate faceplate, glass reinforced VSE-2300HB Heater/Blower 24/25 polycarbonate end caps, neoprene gasket, ethylene propylene seal, and all stainless steel hardware. VSE-2400 --- Finish: Gray VSE-2400H Heater 24/23 VSE-240
Inhaltszusammenfassung zur Seite Nr. 6
6 INSTALLATION 6.3 Housing Mounting This installation should be made by qualified service 1. Use the two 1/4-20 x 0.50-inch screws and 1/4-inch spring personnel and conform to the National Electrical Code and washers provided in the hardware kit to mount the applicable local codes. housing to a mount or a pan/tilt. The spring washers must be used for the screws to thread properly. 6.1 TOOLS REQUIRED - Small flat blade screwdriver. 2. The outermost set of 1/4-20 threaded holes are for - Phillip
Inhaltszusammenfassung zur Seite Nr. 7
6.5 Camera/Lens Installation VSE-2400 Series: 1. Loosen the two screws holding the camera bracket to the 3. Attach the lens to the camera. base. It is not necessary to remove them completely. See Figure 3. 4. Use the various 1/4-20 screws and spacers provided to mount the camera and the lens to the camera bracket. 6.6 Camera/Lens Wiring WARNING: Only use the cables specified under "INSTALLATION, Cable Requirements" for wiring of all cameras and lenses. 6.6.1 Fittings 1. The two large 1/2-inch N
Inhaltszusammenfassung zur Seite Nr. 8
3. The terminal block provided on /x0 units accepts wire Rear Cap 2 ranging from 20 to 14 AWG or 1.5 mm . The terminal block provided on /x1 units accepts wire ranging from 18 2 to 12 AWG or 2.5 mm . When using larger wire sizes, splice to a smaller size wire at the terminal block end. Remove These Dome Plugs The splice may need to be enclosed in a junction box if it does not pass through the fittings. 1/2-inch Rubber Plugs 4. A screw/terminal lug is provided for securing a safety ground. To at
Inhaltszusammenfassung zur Seite Nr. 9
Be sure to securely tighten all fittings to ensure a 6.8 Lens Wiring liquid-tight seal. Failure to do so could allow water to WARNING: Only use the cables specified enter the housing and damage the camera and lens. under "INSTALLATION, Cable Requirements" for wiring of the lens. 6. Connect the supply power wires to the left side or the top side of the terminal block provided. Strip no less than 1. Install the last 1/2-inch NPT fitting into the remaining hole 6 mm (0.25-inch) and no more than 8 m
Inhaltszusammenfassung zur Seite Nr. 10
See Detail Cover Rib Seal Top of Base Figure 10: Reinstalling the Cover 3. As the cover nears the rear cap, make sure the captive screws in the back are not blocking the cover from engaging into the rear cap. 4. Screw the two rear captive screws into the housing. 6.11 Fuse Replacement 1. To replace a fuse, take a flat blade screwdriver and twist the top of the fuseholder counterclockwise about a quarter of a turn. The fuse is spring loaded so it will eject. 2. Replace the fuse with a fuse that h
Inhaltszusammenfassung zur Seite Nr. 11
SANYO INDUSTRIAL VIDEO HOUSINGS OR INTEGRATED CAMERA/LENS/HOUSING PACKAGES OBLIGATIONS In order to obtain warranty service, the product must be delivered to and picked up from an Authorized Sanyo Service Center at the user’s expense, unless specifically stated otherwise in this warranty. The names and addresses of Authorized Sanyo Service Centers may be obtained by calling the toll- free number listed below. For product operation, authorized service center referral, service assistance or problem
Inhaltszusammenfassung zur Seite Nr. 12
Sanyo Fisher Company Security Video Division 21605 Plummer Street Chatsworth, CA 91311 Tel: (818) 998-7322 Fax: (818) 717-2716 Technical Support: (888) 66SANYO 100 0004 001 SAN 6/02 Printed in USA