Inhaltszusammenfassung zur Seite Nr. 1
Hardware Maintenance Manual
IBM
xSeries 330
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
Hardware Maintenance Manual IBM xSeries 330
Inhaltszusammenfassung zur Seite Nr. 4
Note: Before using this information and the product it supports, be sure to read the general information under “Notices” on page 147. First Edition (September 2000) INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain tr
Inhaltszusammenfassung zur Seite Nr. 5
About this manual This manual contains diagnostic information, a Symptom-to-FRU index, service ® information, error codes, error messages, and configuration information for the IBM xSeries 330. Important: This manual is intended for trained servicers who are familiar with IBM PC Server products. Important safety information Be sure to read all caution and danger statements in this book before performing any of the instructions. Leia todas as instruções de cuidado e perigo antes de executar q
Inhaltszusammenfassung zur Seite Nr. 6
Prenez connaissance de toutes les consignes de type Attention et Danger avant de procéder aux opérations décrites par les instructions. Lesen Sie alle Sicherheitshinweise, bevor Sie eine Anweisung ausführen. Accertarsi di leggere tutti gli avvisi di attenzione e di pericolo prima di effettuare qualsiasi operazione. Lea atentamente todas las declaraciones de precaución y peligro ante de llevar a cabo cualquier operación. Online Support Use the World Wide Web (WWW) to download Diagnostic, BI
Inhaltszusammenfassung zur Seite Nr. 7
Contents About this manual . . . . . . . . . . . . . . . . . . . iii Chapter 5.Installing options . . . . . . . . . . . 39 Important safety information . . . . . . . . . . . . . . . . . . . . . . iii Major components of the xSeries 330 server . . . . . . . . . 39 Online Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv System board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 IBM Online Addresses . . . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 8
System shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Chapter 9.Related service information . 107 Voltage related system shutdown . . . . . . . . . . . . . . . 96 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Temperature related system shutdown . . . . . . . . . . 97 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 DASD checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 9
Chapter 1. General checkout The server diagnostic programs are stored in upgradable read-only memory (ROM) on the system board. These programs are the primary method of testing the major components of the server: the system board, Ethernet controller, video controller, RAM, keyboard, mouse (pointing device), diskette drive, serial ports, and hard drives. You can also use them to test some external devices. See “Diagnostic programs and error messages” on page 15. Also, if you cannot dete
Inhaltszusammenfassung zur Seite Nr. 10
Power-on the computer. If the computer hangs and no error is displayed, go to “Undetermined problems” on page 98. Record any POST error messages displayed on the screen. If an error is displayed, look up the first error in the “POST error codes” on page 90. Check the information LED panel System Error LED; if on, see “Information panel system error LED” on page 85. Check the System Error Log. If an error was recorded by the system, see “Chapter 7. Symptom-to-FRU index,” on pag
Inhaltszusammenfassung zur Seite Nr. 11
Chapter 2. General information ® 1 The IBM xSeries 330 server is a one U-high rack-model server for high- volume network transaction processing. This high-performance, symmetric multiprocessing (SMP) server is ideally suited for networking environments that require superior microprocessor performance, efficient memory management, flexibility, and reliable data storage. The xSeries 330 server comes with a three-year limited warranty and IBM Server Start Up Support. If you have access to the
Inhaltszusammenfassung zur Seite Nr. 12
Features and specifications The following table provides a summary of the features and specifications for the xSeries 330 server. Table 1. Features and Specifications. Microprocessor: Size Environment: ® ® Intel Pentium III Height 43.69 mm (1.72") Air temperature: microprocessor with MMX™ Depth: 653.29 mm (25.72") — Server on: 10º to 35º C (50.0º to technology and SIMD 95.0º F). Altitude: 0 to 914 m Width: 439.93 mm (17.32") extensions (2998.7 ft.) Weight: approximately
Inhaltszusammenfassung zur Seite Nr. 13
Impressive performance using an innovative approach to SMP The server supports up to two Pentium III microprocessors. The server comes with one microprocessor installed; you can install an additional microprocessor to enhance performance and provide SMP capability. Large system memory The memory bus in the server supports up to 4 gigabytes (GB) of system memory. The memory controller provides error correcting code (ECC) support for up to four industry standard PC133, 3.3 V, 168-pin,
Inhaltszusammenfassung zur Seite Nr. 14
Error codes and messages System error logging Upgradable BIOS, diagnostics, and Advanced System Management Processor code Automatic restart after a power failure Parity checking on the PCI buses CRC checking on the SCSI buses Error checking and correcting (ECC) memory Redundant Ethernet capabilities Light Path Diagnostics™ on the system board Vital Product Data (VPD) on system board, and SCSI backplane Server controls and indicators This section identifies the controls and
Inhaltszusammenfassung zur Seite Nr. 15
Hard disk drive activity light: Each of the hot-swap drives has a Hard Disk Activity light. When this green LED is flashing, the controller is accessing the drive. CD eject button: Push this button to release a CD from the drive. CD drive activity light: When this light is on, it indicates that the CD-ROM drive is in use. Rear view Ethernet 1 speed indicator (green) C2T IN port Ethernet 1 link Advanced systems indicator (green) management RS-485 Select light (green) USB 2 Serial port USB
Inhaltszusammenfassung zur Seite Nr. 16
Power-on light: This green LED lights and stays on when you turn on your server and will blink when the server is in standby mode. This light duplicates the power on light on the front of the server. Ethernet 2 link indicator: This green LED lights when there is an active link connection on the 10BASE-T or 100BASE-TX interface for Ethernet port 2. Ethernet 2 speed indicator: This green LED lights when the speed of the Ethernet LAN connected to Ethernet port 2 is 100 Mbps. Turning on th
Inhaltszusammenfassung zur Seite Nr. 17
Complete the following steps to turn off the server: 1. Refer to your operating system documentation for the proper procedure to shut down the operating system. Note: Each operating system is different. Some will allow an immediate shut- down, while others require and orderly shut-down procedure. 2. Press the power control button on the front of the server. This will put the server in the stand-by mode. 3. Disconnect the server from the power source. Note: After turning off the server, wai
Inhaltszusammenfassung zur Seite Nr. 18
10 Hardware Maintenance Manual: xSeries 330
Inhaltszusammenfassung zur Seite Nr. 19
Chapter 3. Diagnostics This section provides basic troubleshooting information to help you resolve some common problems that might occur with the server. Diagnostic tools overview The following tools are available to help you identify and resolve hardware-related problems: POST beep codes, error messages, and error logs The power-on self-test (POST) generates beep codes and messages to indicate successful test completion or the detection of a problem. See “POST” on page 12 for more infor
Inhaltszusammenfassung zur Seite Nr. 20
POST When you turn on the server, it performs a series of tests to check the operation of server components and some of the options installed in the server. This series of tests is called the power-on self-test or POST. If POST finishes without detecting any problems, a single beep sounds and the first screen of your operating system or application program appears. If POST detects a problem, more than one beep sounds and an error message appears on your screen. See “POST error messages” f