Inhaltszusammenfassung zur Seite Nr. 1
QUICK START
IX and IXE Series
Network Camera
™
Sarix Technology
C2951M-C (12/09)
Inhaltszusammenfassung zur Seite Nr. 2
Product Overview PoE ACC 24V~ RELAY R1 ALARM A1 (FRONT COVER OPENED) FV Figure 1. Camera Connections and Features C2951M-C (12/09) 2 RESET LINK ACT
Inhaltszusammenfassung zur Seite Nr. 3
ì RJ-45 Network Port: Connects the camera to the network. Also supplies power to the camera through the network using Power over Ethernet (PoE). If PoE is not available, the camera is prewired for 24 VAC. î Ethernet Activity LED: Flashes green to indicate that data is being transmitted/received by the camera. ï Ethernet Link LED: Glows solid amber to indicate that a live connection is established. ñ Accessory Port: For use with compatible Pelco accessories. ó 24 VAC Power, Relay, and Alarm Co
Inhaltszusammenfassung zur Seite Nr. 4
Installation NOTES: • For detailed instructions, refer to the IX Series Installation/Operation manual or the IXE Series Installation/Operation manual. Both are available on the resource disc. • Megapixel lenses are designed and tested to deliver optimal image quality to the IX Series and IXE Series megapixel cameras. A standard definition lens installed on a megapixel camera will limit the resolution of the camera and create poor image quality. 1. Install the lens: a. Remove the cover from th
Inhaltszusammenfassung zur Seite Nr. 5
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 1 2 3 4 5 6 7 8 3. Connect the network cable to the RJ-45 network port located at the back of the camera (refer to Figure 3). NOTE: If the network has no Power over Ethernet (PoE), connect a 24 VAC Class 2 power supply to the 24 VAC power connector (refer to Figure 4). 1 8 Pin Function 1TX+ 8 2TX– 1 3RX+ 4 PoE 1-2 5 PoE 1-2 6 RX– 7 PoE 3-4 8 PoE 3-4 Figure 3. Pin Descriptions 4. For Class B installations, attach the supplied fe
Inhaltszusammenfassung zur Seite Nr. 6
Operation Once the camera is installed, apply power to the camera. The camera will start a configuration sequence. The green LED flashes five times per second for approximately two minutes and then turns solid after the boot cycle is complete and the camera is on line. IP ADDRESS SETTINGS If the camera is connected to a Dynamic Host Configuration Protocol (DHCP) network and DHCP is set to the On position, the server will automatically assign an IP address to the device; DHCP On is the defaul
Inhaltszusammenfassung zur Seite Nr. 7
MINIMUM SYSTEM REQUIREMENTS IX SERIES ® ® Processor: Intel Pentium 4 microprocessor, 1.6 GHz ® ® ® ® Operating System: Microsoft Windows XP, Windows Vista , or Mac OS X 10.4 (or later) Memory: 512 MB RAM Network Interface Card: 100 megabits (or greater) Monitor: Minimum of 1024 x 768 resolution, 16- or 32-bit pixel color resolution ® ® ® Web Browser: Internet Explorer 7.0 (or later) or Mozilla Firefox 3.0 (or later) NOTE: Internet Explorer is not supported by Mac OS X 10.4. ® ® ® Media Player:
Inhaltszusammenfassung zur Seite Nr. 8
LIVE PAGE ICONS Viewable icons are based on group permissions. The camera has two predefined groups: Public and Admin. Public: This defined group can be modified or deleted. The default permissions for this group are single stream view, stream selection, and API access. Admin: This is the only defined group that cannot be deleted; however, the administrator password can be changed. For security purposes, it is important that you change your password after you log on to the device for the firs
Inhaltszusammenfassung zur Seite Nr. 9
SYSTEM TAB General Settings: Includes programmable fields for the device name, time server, and text overlay settings. You can also use the General Settings page to turn the camera’s power LED on or off and to configure the Simple Mail Transfer Protocol (SMTP) server to send an email notification when an event handler is activated. System Information: Includes read-only fields for the firmware version, hardware version, model number, and serial number of the system. This information is typic
Inhaltszusammenfassung zur Seite Nr. 10
A/V STREAMS TAB Use the A/V Streams tab to configure the video and audio streams for the camera. The A/V Streams tab includes a Video Presets page, a Video Configuration page, and an Audio Configuration page. Video Presets: The Video Preset page includes three fully-configured video presets, which include primary and secondary video stream settings for easy setup. These presets may also be used as a starting point for a custom video configuration. These preset configurations vary depending on
Inhaltszusammenfassung zur Seite Nr. 11
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years: – Fiber optic products – Unshielded Twisted Pair (UTP) transmission products – CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models • Three years: ™ – Pelco-designed fixed network cameras and netwo
Inhaltszusammenfassung zur Seite Nr. 12
www.pelco.com Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel (800) 289-9100 Fax (800) 289-9150 International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120