ZOOM FOCUS IRIS
AUX AUX PAN CAM UP
ON
1 3 AUTO ON TELE NEAR OPEN
LEFT RIGHT
DOWN OFF
WIDE FAR CLOSE
WIRETRON 2 4 MAN OFF
®
MPT8000 Series
Wiretron Digital
Transmitter/
Controller and
WX8000 Series
Receiver/Driver
Installation/
Operation Manual
C585M-B (11/98)
U
® L
LISTED
Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel (1-559) 2
Inhaltszusammenfassung zur Seite Nr. 2
CONTENTS Section Page 1.0 GENERAL ..................................................................................................5 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 5 1.2 UNPACKING INSTRUCTIONS .......................................................... 6 1.3 RECOMMENDED TOOLS ................................................................. 6 2.0 DESCRIPTION .......................................................................................... 7 2.1 MOD
Inhaltszusammenfassung zur Seite Nr. 3
LIST OF ILLUSTRATIONS Figure Page 1 Basic Wiretron System Configuration ................................................9 2 Multiple Camera Wiretron System ..................................................... 9 3 Circuit Board Electrical Connections ................................................10 4 24 VAC Power Input Modification Diagram ....................................... 11 5 Basic Wiretron Interconnect Diagram ............................................... 13 6 Connector Assembly ...
Inhaltszusammenfassung zur Seite Nr. 4
(This page intentionally left blank.) 4 Pelco Manual C585M-B (11/98)
Inhaltszusammenfassung zur Seite Nr. 5
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco.
Inhaltszusammenfassung zur Seite Nr. 6
1.2 UNPACKING INSTRUCTIONS Unpack and inspect all parts carefully. The following items are supplied: 1 MPT8000 Series Wiretron Controller or 1 WX8000 Series Receiver/Driver 1 Installation/Operation Manual (C585M-B) Be sure to save the shipping carton, boxes and inserts. They are the safest materi- als in which to make future shipments. If an item appears to have been damaged in shipment, replace it properly in its box and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replacement
Inhaltszusammenfassung zur Seite Nr. 7
2.0 DESCRIPTION The Wiretron digital control system operates over a two-conductor cable and con- trols CCTV equipment such as pan/tilts, enclosures, and motorized zoom lenses from a remote location up to 10 miles (16 km) away. Wiretron can be configured to control a single site or interfaced with Pelco video switching equipment to provide a convenient video/control system with multiple control sites and/or multiple camera sites. The Wiretron control system provides up to 15 remote control funct
Inhaltszusammenfassung zur Seite Nr. 8
2.1.2 Wiretron Receiver/Driver Outdoor WX8024RX Wiretron receiver in weatherproof box for 24 VAC pan/tilts with power supply for pan/ tilt, zoom lens, 24 VAC camera power, 120 VAC input WX8024RX/220 Same as WX8024RX except 230 VAC input WX8115RX Wiretron receiver in weatherproof box for 120 VAC pan/tilts with power supply for pan/ tilt, zoom lens, 120 VAC camera power, 120 VAC input WX8220RX Same as WX8115RX except 230 VAC input, 230 VAC pan/tilt output WX8224RX Same as WX8024RX except 24 VAC i
Inhaltszusammenfassung zur Seite Nr. 9
3.0 INSTALLATION The simplest Wiretron system, consisting of the control transmitter and receiver, is shown in Figure 1. Up to 15 control functions are transmitted over the transmission line to the remotely located receiver. These signals are then converted to drive voltages or relay switching for auxiliary equipment being controlled. The basic sys- tem can be expanded to control multiple camera sites with the addition of a manual video switcher with balanced audio follow (BAF), as shown in Fig
Inhaltszusammenfassung zur Seite Nr. 10
} } 3.1 RECEIVER 24 VAC POWER INPUT MODIFICATION The WX8024RX series receivers can be converted to operate with 24 VAC input. To convert the receiver, disconnect the receiver circuit board and assembly from the enclosure. The patch panel circuit board is located on the bottom of the receiver circuit board mounting plate and requires the following modifications for 24 VAC operation (refer to Figures 3 and 4.) NOTE: Parts needed for modifi- 1. Turn off the power to the receiver and remove the pow
Inhaltszusammenfassung zur Seite Nr. 11
1P6 66 94V0 9648 T3 T2 T1 24V P/T 24V CAM 28VCT 3 J2 5 3 J2 5 J2 5 3 110V 6 J3 110V 6 J3 110V 6 J3 2 2 220V 220V 220V 4 4 4 110V 110V 110V 1 J1 7 1 7 1 J1 7 J1 88 8 BLUE/WHITE J4 J5 J6 YELLOW 99 9 BLUE GND J4 J5 J6 F1 F2 F3 1P7 T3 BROWN/WHITE BROWN CUT WIRES SHORT AND BLACK/WHITE INSULATE BLACK RED RED/WHITE WHITE GREEN BLUE BLACK VIOLET 24 VAC INPUT 24 VAC OUTPUT F2 F3 CAM P/T 1A 3A Figure 4. 24 VAC Power Input Modification Diagram Pelco Manual C585M-B (11/98) 11
Inhaltszusammenfassung zur Seite Nr. 12
3.2 MOUNTING 3.2.1 Transmitter/Controller NOTE: Never mount the receiver Transmitter/controllers in the MPT8000 Series are desktop units. Determine the with wiring connectors facing up. best location for the unit. Always have the connectors facing Proceed to Section 3.2.2, RECEIVER. down to prevent water damage. 3.2.2 Receiver 1. Determine the best location to install the unit. NOTE: When installing the WX8000 receiver to a wall out- 2. Using the WX8000 receiver box as a template, mark the h
Inhaltszusammenfassung zur Seite Nr. 13
HI LOW GND CAUTION: WX8000 SERIES RECEIVER HAZARDOUS VOLTAGE MAY EXIST 22 1 P3 AC 3 LOW GND 2 TEST HI AC 1 MODULE HIGH CX900TLC LOW AC INPUT AUTO/RANDOM GND SCAN MODULE F3 A9000 F2 F1 J2 PS 1 8 10 1 P2 P1 1 14 MPT8000 SERIES CONTROLLER TB1 HI LOW GND AC INPUT Figure 5. Basic Wiretron Interconnect Diagram 3.3.1.2 Wiring from the Receiver/Driver t
Inhaltszusammenfassung zur Seite Nr. 14
3. Slide the connector pins into the appropriate holes in the connector body until they snap into place. Refer to Figures 4 and 5 for correct pin arrangement, depending on model and options. 4. Push the connector clamp assembly (with boot, if used) toward the connector body. Screw the clamp assembly onto the connector body, being careful not to disturb the wires. 5. To complete the assembly, attach the appropriate clamp with the screws pro- vided and tighten. 6. When you are finished wiring the
Inhaltszusammenfassung zur Seite Nr. 15
RECEIVER CONTROL RECEIVER CONTROL INPUT OUTPUT PIN ASSIGNMENT PIN ASSIGNMENT P1 BRN P/T COM 3 1 4 1 9 5 ORG LEFT 5 3 15 10 22 16 N/C 8 4 28 23 33 29 GRN DOWN 7 5 37 34 BLU UP 6 6 VIO RIGHT 4 7 GRAY GROUND 9 8 G BLK IRIS 12 10 1 W/BRN FOCUS 11 11 3 LENS INPUT 10 W/RED ZOOM 12 2 14 13 4 W/ORG LENS COM 13 2 5 RED MAN IRIS 1 9 WHITE CAM AC HIGH CAMERA 2 14 W/YEL CAM AC LOW POWER P2 BRN/W N/C 28 10 RED/W N/C 29 9 ORG/W AUX 1 30 8 YEL/W N/C 31 7 AUXILIARY WIRING GRN/W AUX 4 32 PROVIDED IN 6 OUTDOOR MO
Inhaltszusammenfassung zur Seite Nr. 16
3.3.2 Auxiliary Functions WARNING: Mechanical The Wiretron receiver is capable of operating up to four remotely activated auxiliary functions. Each auxiliary output may be individually converted at the receiver for relays used must not ex- momentary or latching operation. Refer to Figure 8 to set jumpers for auxiliary func- ceed 10 VDC at 25 mA. tions. When in the latching mode, activating the same AUX function will toggle the Applications with higher function from on to off. power requirements
Inhaltszusammenfassung zur Seite Nr. 17
WIRETRON Figure 9. Auxiliary Functions Wiring Diagram + 12 VDC NORMALLY-OPEN CONTACTS WIRETRON RECEIVER/DRIVER 10 VDC RELAY 37-PIN CONNECTOR 1N4005 25 mA COIL CURRENT MAXIMUM 1 MANUAL IRIS 2 NOTE: CUSTOMER SUPPLIES PARTS AND 12 VDC 3 POWER SUPPLY CONNECT TO NEGATIVE 8 GROUND SIDE OF 12 VDC SUPPLY Figure 10. External Device Wiring Diagram Pelco Manual C585M-B (11/98) 17
Inhaltszusammenfassung zur Seite Nr. 18
3.3.3.1 Long Distance Cable Installation Because of the many options available, long distance video wiring is at your discre- tion. Review the following to determine the best method of wiring video for your application. Maximum Distance Recommendations for Coaxial Cable There are a number of variables to consider when specifying the type of coaxial cable to run. It is best to avoid the use of video amplifiers. Video amplifiers should be regarded as a remedy for an existing problem not as an ins
Inhaltszusammenfassung zur Seite Nr. 19
Fiber Optic Cabling Fiber optic transmission of both video and control presents some distinct advan- tages. Higher quality and longer distance transmission characteristics, inherent noise resistance, greater flexibility for usage, and reduced cabling diameter are but a few of these advantages. The incorporation of fiber optics systems are encouraged, especially when covering long distances and when seeking to maintain the highest quality video signals. Consult with equipment manufacturers and fi
Inhaltszusammenfassung zur Seite Nr. 20
Table B. Video Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance All-copper center conductor All-copper braided shield with 95% braid coverage Table C. 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-