Inhaltszusammenfassung zur Seite Nr. 1
DOME TYPE CAMERA
INSTRUCTIONS
TK-C655
LWT0050
Inhaltszusammenfassung zur Seite Nr. 2
IMPORTANT SAFEGUARDS 1. Read all of these instructions. 2. Save these instructions for later use. 3. All warnings on the product and in the operating instructions should be adhered to. 4. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5. Do not use attachments not recommended by the appliance manufacturer as they may cause hazards. 6. Do not use this appliance near water – for example,
Inhaltszusammenfassung zur Seite Nr. 3
WARNING: AVERTISSEMENT: TO REDUCE THE RISK OF FIRE OR POUR EVITER LES RISQUES D'INCENDIE OU ELECTRIC SHOCK, DO NOT EXPOSE THIS D'ELECTROCUTION, NE PAS EXPOSER APPLIANCE TO RAIN OR MOISTURE. L'APPAREIL A L'HUMIDITE OU A LA PLUIE. Thank you for purchasing this product. (These instructions are for TK-C655E) Before beginning to operate this unit, please read the instruction manual carefully in order to make sure that the best possible performance is obtained. Contents Introduction Features ........
Inhaltszusammenfassung zur Seite Nr. 4
Introduction Features DSP with a wide dynamic range Even objects differing greatly in brightness can be monitored clearly. Private masking facility When the camera target area needs to be hidden, the camera can be set accordingly to mask it. Optical zoom lens Detailed surveillance can be performed with the approx. 25 times optical zoom lens. High-speed pan/tilt table The high-speed rotating table with a horizontal panning speed of 300°/sec. and a vertical tilting speed of 180°/sec. makes
Inhaltszusammenfassung zur Seite Nr. 5
Precautions for Correct Operation ● In auto iris mode, when the AGC circuit is ON, varying the iris with Note on consumable parts the iris control button may not change the picture brightness. This The following parts are consumable and should be replaced is due to the automatic gain boost by the AGC circuit. In this case, after a certain number of hours or a count of operations. set AGC to OFF or use the manual iris mode. The service lives given below are only typical values. They may vary de
Inhaltszusammenfassung zur Seite Nr. 6
Introduction Controls, Connectors and Indicators ■ Camera body Ceiling Mount 0 Cover 8 7 9 6 9 CONTROL terminal 8 (CN22) 7 1 5 2 6 3 4 (Connector side) (Terminal Layout) [VIDEO OUT] Coaxial Cable Connectors [CONTROL] Terminals (CN22) 1 8 Output connector of a composite video signal (1 V(p-p)) Connect to a RM-P2580 remote control unit. with an output impedance of 75 Ω, to be connected to a Pin No. Signal Name Mark switcher, etc. 1 TX + A [AC` 24V INPUT] Connector 2 2 TX – B Connect to a 24
Inhaltszusammenfassung zur Seite Nr. 7
Ceiling Mount Camera & ^ % # $ * ⁄ ! # @ ) (Setting switch side) ( Camera Connector (Female) Drop Prevention Wire ! & Connect to , the Male Connector on the camera. Attach this wire to the Drop Prevention Hook on the ^ @ Ceiling Mount. Drop Prevention Hook @ Attach the Drop Prevention Wire to this hook to prevent Camera Clamping Bracket & * the camera from falling. In order to clamp the camera onto the Ceiling Mount, in- sert and tighten the Locking Screw into this bracket. 4 Clamping H
Inhaltszusammenfassung zur Seite Nr. 8
7 7 6 6 5 5 4 4 3 3 Connections & Installation A Multi-Drop Communication System A system that employs the RM-P2580 as the controller The following figure shows a system that can accommodate up to eight cameras. (64 positions can be preset per camera.) Control signal cable Observe the following points when connecting compo- TK-C655 Coaxial cable nents together: Camera 1 •Turn all the components off before proceeding. AC 24 V power supply • Read the instruction manuals of all components before
Inhaltszusammenfassung zur Seite Nr. 9
A system that does not employ the RM-P2580 as the controller MEMO Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of non-terminated equipment (cameras or controllers) must be as short as possible. If the length of stub is too long, the precision of the control may suffer. ● When the controller is located in the middle of the system cable. (An AC 24V power source must be supplied to each camera) CONTROL Cable Length of stub Length of stu
Inhaltszusammenfassung zur Seite Nr. 10
Connections & Installation Point-to-Point Communication System The following illustration shows a system in which a remote control unit (or a similar piece of equipment) controls a single camera. Video out Control signal cable AC 24 V power supply Monitor Switch 4 : OFF (Point to Point) Switch 8 : ON Controller (Terminated 110Ω) Observe the following points when connecting system components : •Turn all the components power off before proceeding. • Read the instruction manuals of each component b
Inhaltszusammenfassung zur Seite Nr. 11
Use twisted-pair cables for the connections. ●Duplex ●Simplex When the camera is controlled using the full duplex trans- When the camera is controlled using the simplex trans- mission protocol, set Switch 5 to OFF. mission protocol, set Switch 5 to ON. Camera Controller Camera Controller RX+ TX+ RX+ TX+ RX– TX– RX– TX– TX+ RX+ Two wires must be connected. TX– RX– Four wires must be connected. For example (connection with an RM-P2580) Camera RM-P2580 RX+ C C TX+ RX– D D TX– TX+ A A RX+ TX–
Inhaltszusammenfassung zur Seite Nr. 12
Connections & Installation Switch Settings Set the switches on the Ceiling Mount prior to installing the camera. Settings will vary according to the configuration of the system. Setting switches Switch 1 Reserved This switch must be set “OFF” Switch 2 Switch 3 DISP Switch 4 PROTOCOL(1) Switch 5 PROTOCOL(2) Switch 6 SYNC Switch 7 Reserved This switch must be set “OFF” Switch 8 RX TERM ● Switches 1, 2 ● SYNC (Switch 6) When this switch is set to ON, the vertical sync of the camera These switche
Inhaltszusammenfassung zur Seite Nr. 13
7 7 4 4 6 6 3 3 5 5 2 2 4 4 1 1 3 3 Setting switches Figure of 1 Figure of 10 ● Machine ID MEMO When using a multi-drop system with a remote control unit In a system using an RM-P2580, multiple cameras are connected such as a RM-P2580, the machine IDs need to be set for by a single set of control cables. An error in the switch setting of each camera. even a single camera will make the entire system inoperable. Machine IDs are used to identify each of the multiple cam- eras connected to the RM-
Inhaltszusammenfassung zur Seite Nr. 14
Connections & Installation Cable Connections Connect cables to the Ceiling Mount as described below. 1. Make a 90 mm diameter hole in the ceiling. 4. Connect the cables. Connect the cables to the terminals on the Ceiling Mount. The four connections consist of a AC 24V power cable, a Diameter 90 mm coaxial cable and a control signal cable. Control signal cable To a remote controller such as RM-P2580 2. Remove the cover from the Ceiling Mount. To the monitor, etc. Power cable To the AC 24 V RELEA
Inhaltszusammenfassung zur Seite Nr. 15
Coaxial cable Control signal cables Connecting a RG-59 coaxial cable. The RM-P2580 unit allows the connection of up to eight cam- eras to the one set of control signal cables. The overall maxi- If a RG-11 coaxial cable is used it cannot be con- mum permissible length of these control signal cables is 1200 nected directly to the terminal board. To use such a metres. cable, connect a RG-59 cable to the camera and then connect the RG-11 cable to the RG-59 cable. Cable Flat-blade Trim the end of th
Inhaltszusammenfassung zur Seite Nr. 16
Connections & Installation Attaching the Ceiling Mount To a ceiling slab or channel 1. Attaching a safety wire. Attach a safety wire to the Ceiling Mount and to the ceil- ing slab or channel to prevent the unit from being able to fall to the floor. First attach the safety wire to the Ceiling Mount by passing the wire through the safety wire hole Safety wire hole (see the diagram on the left). MEMO ● Connect the wire so that it can be insulated from the ceiling struc- ture. If the ceiling struc
Inhaltszusammenfassung zur Seite Nr. 17
Ceiling Mount 2. Ensure that the locking screw is loose. Locking screw The camera cannot be attached properly if the locking screw of the Ceiling Mount is too tight at this stage. Camera 3. Fit the camera. Camera clamping Check the position of the camera clamping bracket and bracket that of the locking screw, and fit the camera to the Ceiling Mount. Camera clamping bracket 4. Rotate the camera. Make sure that the camera is horizontal, then turn the camera clockwise until it stops. Ensure that
Inhaltszusammenfassung zur Seite Nr. 18
Setting Up the Camera Using an RM-P2580 Setup Procedure In systems using an RM-P2580 remote control unit, the menus for use during camera setup can be displayed on the remote control unit. (Please refer to the instructions for RM-P2580.) MENU button Power switch 1. Set the Power switch on the rear panel of the RM- (Rear panel) P2580 to ON. SET button The POWER lamp lights up. POWER lamp REMOTE CONTROL UNIT RM-P2580 CAMERA POSITION SETUP POWER ALARM M
Inhaltszusammenfassung zur Seite Nr. 19
Menu Screen Flow The menu screens are arranged in a hierarchical structure as shown below. Refer to the respective reference pages for the details of each menu. Normal screen P.20 ☞ SE TUP ––CAME RA F UNC T I O N – – POS I T I ON S E T U P . . V.PHASE 0 CAME RA . . POS . T I T L E L OC . U P - L CON T RO L U N I T . . FL I P D IGI TA L VAR . P / T S PEED ON EASY A F OF F V .SHARP NE S S NORMA L PR I V A T E MASK . . P.21 ☞ –––CAMERA T I T L E / A L ARM––– CAM . T I T L E E D I T . . ARE A T
Inhaltszusammenfassung zur Seite Nr. 20
Setting Up the Camera Using an RM-P2580 CAMERA FUNCTION Screen This screen sets up the functions of the camera itself. Item Function & Setting Initial Value V. PHASE This adjusts the vertical synchronization to those of other cameras when a selector 0 switch for the synchronizing system on the Ceilling Mount is at LL. (50 Hz power region only.) Setting values : –156 to 0 to 156 POS. TITLE LOC. Sets the location of the position title and area title in the monitor. UP-L UP : At the top of the scr