Inhaltszusammenfassung zur Seite Nr. 1
TK-C210FW/TK-C215V4/
TK-C215V12
DOME CAMERA
DOME CAMERA
INSTRUCTIONS
TK-C210FW
TK-C215V4
TK-C215V12
For Customer Use:
Enter below the Serial No. which is located on the body.
Retain this information for future reference.
Model No. TK-C210FW/TK-C215V4/TK-C215V12
Serial No.
Printed in Thailand
LST0308-001B-H
LST0308-001B-H
© 2005 Victor Company of Japan, Limited
Inhaltszusammenfassung zur Seite Nr. 2
Introduction I This installation should be made by a qualified service person and should conform to all local Safety Precautions INFORMATION FOR USA codes. Information for Users on Disposal of Old Equipment INFORMATION This installation shall be in accordance with the National Electrical Code, ANSI/NFPA 70. [European Union] This equipment has been tested and found to comply with the limits for a Class B digital This symbol indicates that the electrical and electronic equipment should
Inhaltszusammenfassung zur Seite Nr. 3
Introduction (continued) Thank you for purchasing this product. This instruction manual covers total 5 different These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances. (These instructions are for: TK-C210FWE, models in common as follows; TK-C215V4U/E, TK-C215V12U/E.) IMPORTANT SAFEGUARDS Before beginning to operate this unit, please read TK-C215V4U the instruction manual carefully in order to make TK-C215V4E 1. Read all of these instructions. sure that the be
Inhaltszusammenfassung zur Seite Nr. 4
Introduction (continued) If the DAY/NIGHT switch is turned on, the mode changes automatically to black and Contents Operating Precautions white in dark places. As the sensitivity increases, the image may look grainy and To save energy, when it is not being used turn white spots may appear. Introduction Others the system’s power off. When changing modes, bright portions of This camera has been designed for indoor Safety Precautions .......................................... 2 Specifi
Inhaltszusammenfassung zur Seite Nr. 5
Introduction (continued) Camera (Interior) Name of Parts The picture below shows the camera when the dome cover and outer case are removed. Camera Procedures for removal. (A pg. 18 AEmbedding the camera to the ceilingB, Step 3. to Step 4.) I H U TK-C215V12 only Lens G (A Next page) A Camera Unit (Rear) F V T B S B N R E Q C P J O A K D N L A Mounting hole (elliptical) x 4 E Wiring Hole M Use these when mounting the camera to the Break and use this when drawing the cable electrical box. (A pg.
Inhaltszusammenfassung zur Seite Nr. 6
Introduction (continued) A [RESET/SPOT] RESET/SPOT button 3. [SYNC] Synchronization system selection therefore appear rougher and white spots switch. may increase. Setting the Lens and When this button is pressed, the value of the white balance or phase adjusted manually is This switch sets the synchronizing system for Switches (TK-C215V4) 7. [RESERVED] reset to the default value. the camera. INT: Not used. Ensure to set this to AOFFB before ● When the 2 [SELECT] switch is set to Set the vi
Inhaltszusammenfassung zur Seite Nr. 7
1 2 2 3 4 4 5 6 7 8 Introduction (continued) B [ZOOM/FOCUS, MEMORY] zoom, focus 2. [SELECT] WHT.BAL./PHASE setting switch. 6. [DAY/NIGHT] Easy DAY & NIGHT switch. adjustment switches/position memory WHT.BAL.: To capture a subject with continually changing Setting the Lens and button The F [R/B, +/-] buttons are used as [R/B] brightness (day/night), set this switch to AONB Switches (TK-C215V12) adjustment buttons. The camera automatically captures the image Use the [JTELE] and [KWIDE] switche
Inhaltszusammenfassung zur Seite Nr. 8
Installation and connection DC 12 V or AC 24 V power supply cable Electrical Specifications of Alarm Input Setting the Lens and About Connection Cables Terminals Connect the DC 12 V or the AC 24 V power Switches (TK-C210FW) The maximum connection distance varies with supply to the DC 12 V/AC 24 V terminals on the (TK-C215V12 only) terminal board. To prevent connection errors or a the type of cable used. Please refer carefully to ● To prevent penetration of noise in the internal Set the vid
Inhaltszusammenfassung zur Seite Nr. 9
Installation and connection (continued) Selecting a mounting method System diagram Mounting the Camera to the Select a method for mounting the camera Ceiling according to the intended purpose. TK-C215V4 AEmbedding the camera to the ceilingB Video signal Getting Started (A pg. 18) Power CAUTION: ● When mounting the camera to the ceiling, AWhen mounting the camera directly to the ensure to wear safety glasses to protect the eye ceiling o
Inhaltszusammenfassung zur Seite Nr. 10
FRONT UP Installation and connection (continued) 4. Remove the outer case. Connecting Mounting Mounting the Camera to the (This method does not require an outer case.) 1. Attach the fall prevention wire to the 1. Align j with the shooting direction when A Loosen the outer case fastening screw with a Ceiling (continued) camera, followed by attaching it to the mounting the camera. screwdriver ceiling slab (Fall prevention wire is not B To remove, turn the camera unit in the anti- included.)
Inhaltszusammenfassung zur Seite Nr. 11
FRONT UP Installation and connection (continued) Installation and connection (continued) 6. Set the switches for video images. Mounting Mounting the Camera to the (TK-C215V4 A pg. 10) 1. Align the position mark of the fastened (TK-C215V12 A pg. 12) Ceiling (continued) outer case with that of the camera unit. (TK-C210FW A pg. 14) Adaptor ring NOTE: 5. When doing so, be careful not to catch the When mounting the camera directly to Pan fasten
Inhaltszusammenfassung zur Seite Nr. 12
FRONT UP Installation and connection (continued) Adjusting Image Mount by allowing the cable to exit from Mounting the Camera to the Adjusting Images Pan : ± 175 the side Ceiling (continued) When mounting the camera to the ceiling or a Upon mounting the camera, adjust the images wall, it is possible to guide the cable from the side while checking the actual image. without opening any holes. When mounting the camera to the The basic mounting method is identical to steps Mounting the test m
Inhaltszusammenfassung zur Seite Nr. 13
1 2 2 3 4 4 5 6 7 8 Optical Axis Adjusting Image (continued) Registering home position TK-C215V4 Adjusting the field angle/focus/ For registering the angle of view during Adjusting Images brightness monitoring under normal conditions. (continued) Iris Level (Not available on TK-C210FW) Adjustment LH IRIS TK-C215V12 LEVEL Focus Adjust 4. Upon determining the imaging direction, adjust Button ● 2 types of angle of view may be selected for the field angle, focus and iris level accordingl
Inhaltszusammenfassung zur Seite Nr. 14
1 2 2 3 4 4 5 6 7 8 1 2 2 3 4 4 5 6 7 8 Adjusting Image (continued) 1. Remove the dome cover. Adjusting Images Mounting the Dome Cover White-spot correction 2. Cover the lens surface using a black sheet (continued) After setting is complete, mount the dome cover. As a general characteristic unique to CCDs, of paper, etc. so that light does not enter the lens. white-spots may appear on the screen with age. Registering alarm position Position mark In order to reduce this phenomenon, this unit
Inhaltszusammenfassung zur Seite Nr. 15
Others TK-C215V12 General Color mode : 8.3 lx (F1.6 AGC ON, Specifications Power supply : U type : AC 24 V 60 Hz 50%,with smoke cover) DC 12 V 2.9 lx (F1.6 AGC ON, E type : AC 24 V H 50 Hz/60 Hz Camera 25%,with smoke cover) DC 12 V d Signal system: 1.3 lx (F1.6 AGC ON, 25%, U type : Based on NTSC standard with optional clear cover) Power consumption E type : Based on PAL standard TK-C210FW: Black and White mode: Scanning frequencies E type : 220 mA 4.9 lx (F1.6 AGC ON, U t
Inhaltszusammenfassung zur Seite Nr. 16
SR55 (2-1/8) SR55 (2-1/8) Others (continued) External Dimensions [Unit: mm (inches)] When cover is attached When embedded 46 (1-13/16) 6 (1/4) φ116 (4-9/16) 4-φ4.5 (3/16) φ145 (5-3/4) φ120 (4-3/4) φ145 (5-3/4) *Specifications and appearance of this unit and related products are subject to change for product improvement without prior notice. Focus chart 30 31 φ89 (3-1/2) φ22 (7/8) 4.5 (3/16) 20 (13/16) 120 (4-3/4) 83.5 (3-5/16) 2 (1/12) 71 (2-13/16) 44 (1-3/4)