Inhaltszusammenfassung zur Seite Nr. 1
METROLOGIC INSTRUMENTS, INC.
™
MS2220 StratosS Scanner / Avery Scale
Installation and User’s Guide
Inhaltszusammenfassung zur Seite Nr. 2
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc.
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS INTRODUCTION Manual Scope ..........................................................................................................................................................................1 Product Overview.....................................................................................................................................................................1 Base Kit Components..........................................................................
Inhaltszusammenfassung zur Seite Nr. 4
TABLE OF CONTENTS SCANNER OPERATION Scan Zone..............................................................................................................................................................................29 IR Activation Area (IR LED Output)........................................................................................................................................31 Indicator Descriptions...........................................................................
Inhaltszusammenfassung zur Seite Nr. 5
TABLE OF CONTENTS SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections..................................................................................................................................................69 Cable Connector Configurations ............................................................................................................................................71 REGULATORY COMPLIANCE Safety.................................................................
Inhaltszusammenfassung zur Seite Nr. 6
v
Inhaltszusammenfassung zur Seite Nr. 7
INTRODUCTION MANUAL SCOPE This guide provides an overview of the MS2220 StratosS scanner/Avery scale operation with detailed information about setup ® ® and installation. Adobe Acrobat versions of the user's manuals are also available for download from the Metrologic website (www.metrologic.com). PRODUCT OVERVIEW Metrologic’s MS2220 StratosS scanner/Avery scale is designed to meet the demanding needs of high volume supermarket and point-of-sale applications. With advanced f
Inhaltszusammenfassung zur Seite Nr. 8
INTRODUCTION OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES Part # Description RS232 Interface Cable 57-57210x-N-3 Straight, 3.7 m (12') Cord with Short Strain Relief 57-57212x-N-3 IBM 46xx Port 9 Cable, Straight 3.7 m (12') Cord OCIA Interface Cable 57-57016x-N-3 Straight, 3.7 m (12') Cord with Short Strain Relief USB Full Speed Communication Cable, 57-57201x-N-3 Straight 4.0 m (13') Cord, Type A (Non-Locking) Connector USB Full Speed Communication Cable, 57-57227x-N-3 ™ Strai
Inhaltszusammenfassung zur Seite Nr. 9
INTRODUCTION OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES Part # Description Optional Remote Scale Display 46-00248 Remote Scale Display for use with MS2000 lb. Scanner/Scales 46-00249 Remote Scale Display for use with MS2000 kg Scanner/Scales Figure 1. Optional Remote Scale Display Dimensions Specifications are subject to change without notice. Figure 2. Optional Remote Scale Display Controls (46-00248 lb, 46-00249 kg) 3
Inhaltszusammenfassung zur Seite Nr. 10
INTRODUCTION REPLACEMENT PARTS REPLACEMENT PARTS Part # Description Window types (Diamonex and Sapphire) are not interchangeable due to laser safety and/or scanner performance differences. Caution To change window type, the scanner must be returned to the manufacturer for reconfiguration. 46-00232 Vertical Window 46-00233 Diamonex Platter - Full Size 46-00296 Diamonex Platter - Full Size, with Product Weight Roll Bar / Platter Lift Handle 46-00235 Sapphire Platter - Full S
Inhaltszusammenfassung zur Seite Nr. 11
INTRODUCTION GENERAL PRECAUTIONS The following are some general precautions to remember when handling your MS2220 Scanner/Avery Scale. DO NOT TURN the unit upside down with the platter in place. Figure 3 DO NOT PRESS on the window in the replacement platter or the vertical window frame. Figure 4 PLATTER REMOVAL No hardware or tools are required to remove the platter (see Figure 5). Refer to the Maintenance section of this manual fo
Inhaltszusammenfassung zur Seite Nr. 12
INTRODUCTION MS2220 SCANNER/AVERY SCALE DESIGN SPECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW Maximum IR LED Output: 50μW per IEC 60825-1 measurement procedure Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code Vertical Depth of Field: 0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) Bar Code Scan Speed: 5400 Scan Lines per Second No. of Scan Lines: 54 (38 Horizontal / 16 Vertical) Motor Speed
Inhaltszusammenfassung zur Seite Nr. 13
INTRODUCTION MS2220 SCANNER/AVERY SCALE DESIGN SPECIFICATIONS Design Specifications Scale Capacities Capacity: kg unit 15 kg lb. unit 30.0 lb. Minimum Increment: kg unit 0.005 kg lb. unit 0.01 lb. Maximum Static Weight: kg unit 75 kg lb. unit 150 lb. Adjustments required: Calibration is required for scaled units. Electrical Voltage Supply: 2A @ +5.2V / 1A @ +12V Operating Power: 11.9 Watts Standby Power: 3.25 Watts Operating Current: 1.5A @ 5.2V / .3A @ 12V Standby C
Inhaltszusammenfassung zur Seite Nr. 14
BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Components Figure 7. MS2220 Components 8
Inhaltszusammenfassung zur Seite Nr. 15
BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Components ITEM NO. DESCRIPTION OF ITEM IN FIGURE 7 1 Scale Zero Button (see page 41) 2 Amber LED, Scale Zero Indicator (see page 41) 3 Volume/Tone Multi-Function Button (see page 39) 4 Blue and White LED Indicators (see page 33) 5 Speaker 6 Finger Recesses for Lifting (Located Under Platter) 7 High Impact Window Frame / Vertical Window (Laser Aperture) 8 Replaceable Stainless Steel Platter with Diamonex or Sapphire Ho
Inhaltszusammenfassung zur Seite Nr. 16
BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Dimensions Figure 8. MS2220 Dimensions Specifications are subject to change without notice. Connector Panel Figure 9. MS2220 Connector Panel 10
Inhaltszusammenfassung zur Seite Nr. 17
BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Caution and Serial Number Labels Figure 10. MS2220 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet app
Inhaltszusammenfassung zur Seite Nr. 18
INSTALLATION QUICK INSTALLATION OUTLINE st The following is a quick preview of the steps required for 1 time installations. Each item is discussed in detail later in this section. • Determine clearance, ventilation and service access requirements. • Determine checkout counter layout taking into account package flow, cable routing and power requirements. • Choose the mounting option which provides the best cable/power access and unit stability. • Unpack the unit. • Make
Inhaltszusammenfassung zur Seite Nr. 19
INSTALLATION SITE REQUIREMENTS Service Access When routing and installing the cable(s) and power supply, make sure you leave access that these components may be swapped easily without the need to remove the unit from the checkout counter. When changing the StratosSWAP™ optics engine modules, Metrologic recommends removing the unit completely from the checkout counter. When calibrating or zeroing the scale, do not remove the unit from the checkout counter. Refer to the Sc
Inhaltszusammenfassung zur Seite Nr. 20
INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check the box’s content for the following items. • Remote Display (Optional) • Product Manuals • Power Supply Figure 11 • Communication Cables 3. Lift the scanner out of the shipping box by gripping the bottom of the unit on both sides. Important! Do not lift the unit out of the box by gripping the sides of the platter.