Inhaltszusammenfassung zur Seite Nr. 1
METROLOGIC INSTRUMENTS, INC.
®
MS7120 Orbit Presentation
Laser Scanner
Installation and User’s Guide
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
LOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com EUROPEAN HEADQUARTERS Germany, Metrologic Instruments GmbH Tel: +49 89 89019 0 Middle East and Africa Dornierstrasse 2 Fax: +49 89 89019 200 82178 Puchheim b. Email: info@europe.metrologic.com Munich, Germany Germany Email: info@de.metrologic.com Spain Met
Inhaltszusammenfassung zur Seite Nr. 4
TABLE OF CONTENTS Introduction................................................................................................1 Scanner and Accessories..........................................................................2 Operational Notes .....................................................................................3 Installation For RS232, OCIA and IBM 46XX Interfaces.........................................4 For Keyboard Wedge Interface.............................................
Inhaltszusammenfassung zur Seite Nr. 5
INTRODUCTION ® Orbit is an aggressive, omnidirectional laser bar code scanner. Lightweight and rugged, Orbit is small in size, but BIG in performance. Designed for applications where counter space is limited, Orbit is the ideal presentation scanner for retail, convenience, liquor and specialty stores. In addition, Orbit’s unique, contoured shape allows it to be picked-up and used as a hand-held scanner when scanning large or bulky items. Engineered with a large, easy-to-find optimal scan area
Inhaltszusammenfassung zur Seite Nr. 6
SCANNER AND ACCESSORIES BASIC KIT Part # Description ® MS7120 Orbit Presentation Laser Scanner ® 00-02407 MetroSelect Programming Guide 00-02408 MS7120 Installation and User’s Guide* * Available on the Metrologic website - www.metrologic.com OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer- Regulated 5.2VDC @ 650 mA output. 45-45593 120V United States 45-45591 220V-240V Continental European 45-45592 220V-240V United Kingdom 46-46803 220V-240V Australia 46-46983 220V-240V China
Inhaltszusammenfassung zur Seite Nr. 7
SCANNER AND ACCESSORIES OPTIONAL ACCESSORIES Part # Description Metrologic Voltage Converter Cable MVC** +12VDC to +5.2VDC or -12VDC to +5.2VDC MX009-2** MX009 USB Converter Cable ** Contact a Metrologic customer service representative for additional information on the MVC and MX009 cable series and the host connections available. 45-45619 Counter/Wall Mount Kit Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Me
Inhaltszusammenfassung zur Seite Nr. 8
INSTALLATION FOR RS232, OCIA AND IBM 46XX INTERFACES 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin jack on the MS7120. 3. Connect the 9 pin female end of the PowerLink cable to the host device. Note: Skip to #6 if receiving power from the host system. 4. Plug the power supply’s L-shaped plug into the power jack on the PowerLink cable. 5. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The
Inhaltszusammenfassung zur Seite Nr. 9
INSTALLATION FOR KEYBOARD WEDGE INTERFACE 1. Turn off the PC/Host. 2. Connect the male 10-pin RJ45 end of the PowerLink cable to the jack on the MS7120. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. 4. Make sure the AC input requirements of the power supply matches the AC outlet. Plug the power supply into the AC outlet. The outlet should be near the equipment and easily accessible. 5. Disconnect the keyboard from the PC. Note the type of connecto
Inhaltszusammenfassung zur Seite Nr. 10
INSTALLATION FOR STAND ALONE KEYBOARD INTERFACE 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin jack on the MS7120. 3. Connect the PowerLink cable to the keyboard port on the host system. 4. Plug the power supply’s L-shaped plug into the power jack on the PowerLink cable. 5. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should be installed near the equipment and be easily access
Inhaltszusammenfassung zur Seite Nr. 11
INSTALLATION NOTES FOR USB INTERFACE Metrologic’s MX009 USB cable is a device that converts serial RS232 formatted data to either USB Keyboard or USB Point-of Sale communication protocol. Please refer to the MX009 USB Converter Cable Programming Guide (MLPN 00-02574A) supplied with your MX009 cable for detailed installation and programming guidelines. INSTALLATION NOTES FOR MS7120-00 LASER EMULATION MS7120-00 Only The MS7120-00 leaves the factory with the Laser Emulation Mode enabled. If you re
Inhaltszusammenfassung zur Seite Nr. 12
SCANNER PARTS Red LED On a successful read of a bar code, the red LED will turn ON. After communication to the host is complete, the red LED will turn OFF. Refer to Visual Indicators and Audible Indicators for additional information. Green LED During normal operation, the green LED is ON. This indicates that the laser is on and the unit is ready to scan. The LEDs are also used as diagnostic indicators and mode indicators. Refer to Visual Indicators and Audible Indicators for additional inform
Inhaltszusammenfassung zur Seite Nr. 13
AUDIBLE INDICATORS When the MS7120 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). ® To change the tone, refer to the MetroSelect Programming Guide (MLPN 00-02407B) or the MetroSet2 help files. One Beep When the scanner first receives power, the green LED will turn on, then the red LED will flash and the scanner will beep once. (The red LED wil
Inhaltszusammenfassung zur Seite Nr. 14
VISUAL INDICATORS There is a red LED and a green LED on the head of the MS7120. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. No Red or Green LED The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Green When the laser is active, the green LED is illuminated. The green LED will remain illuminated until the laser is deactivated. During the power save mode,
Inhaltszusammenfassung zur Seite Nr. 15
FAILURE MODES Flashing Green and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center. Flashing Red and Green and Two Razzberry Tones This indicates the scanner has experienced a motor failure. Return the unit for repair at an authorized service center. Continuous Razzberry Tone with both LEDs off If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an electronic fail
Inhaltszusammenfassung zur Seite Nr. 16
LABELS Each scanner has three labels on the bottom of the unit. These labels contain information such as; the model number, date of manufacture, serial number, laser class and caution statements. The following illustrations show the location and content of the three labels. MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wi
Inhaltszusammenfassung zur Seite Nr. 17
SCAN VOLUME SPECIFICATIONS Specifications based on 100% UPC Bar Codes. Optimal Low Density (Default) 190mm 60mm 100mm Scan Area Optimal High Density 215mm 60mm 105mm Scan Area 13
Inhaltszusammenfassung zur Seite Nr. 18
SCAN VOLUME SPECIFICATIONS (CONT.) Specifications based on 100% UPC Bar Codes. Close 175mm 60mm 95mm Scan Area Normal 190mm 60mm 100mm Scan Area 14
Inhaltszusammenfassung zur Seite Nr. 19
SCAN VOLUME SPECIFICATIONS (CONT.) Specifications based on 100% UPC Bar Codes. Far 215mm 75mm 105mm 75mm Scan Area 15
Inhaltszusammenfassung zur Seite Nr. 20
DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH Optimal Low Density (Default) 0 B & Distance: Scanner Face & To Bar Code (mm) 00 0 0 0 Width of Scan Field (mm) Minimum Bar Code Element Width A BCD E F G H J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.3 6.8 7.5 9 10 13 21 26 16